MC-50T Included:
• MC-50T: Trinocular reflected and transmitted light fiber optic light guide with Koehler illuminator with sliding rotatable polarizer
• MA655/05: Erect image trinocular head with depolarizer
• MA413CF: Focusing eyepiece HWF10X-F with cross-line reticle and guide pin
• MA406: DIN HWF 10X widefield eyepiece, field No. 18
• MA870: Plan Achromat Epi Objective M5X, NA 0.10, infinity corrected, W.D. 20mm
• MA871: Plan Achromat Epi Objective M10X, NA 0.25, infinity corrected, W.D. 7.48mm
• MA872: Plan Achromat Epi Objective M20X, NA 0.40, infinity corrected, W.D. 5.20mm
• MA873: Plan Achromat Epi Objective M50X, NA 0.75, infinity corrected, W.D. 0.38mm
• MA806: Infinity corrected vertical Koehler illuminator with sliding rotatable polarizer Filter Set: Blue Clear, Green Clear, Neutral Density ND8 and Polarizing filter in metal mounts. Port to accept FT190/12 flexible 36” single arm fiber optic light guide
• FT190/12: Flexible 36” single arm light guide for MA806 illuminator
• FT190/115: FT190/115 Light Source 110/120V, 50-60Hz, Halogen lamp, 21V 150W
• FU-1010: Coaxial coarse and fine focus block with quadruple nosepiece
• MA475/05: Blue clear filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
• MA476: Green clear filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
• MA198: ND13 neutral density filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
• MA497: Polarizing filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
• MA729: Reflected & Transmitted light measuring stage: 150mm X 150mm with 50mm X-Y or 6” X 6” with 2” X-Y movement with glass stage plate and mounting brackets for digital micrometer heads
• MAC-11: Heavy duty stand with pillar and mounting bracket with 96.5mm diameter recess mounting surface hole
Model
|
Head
|
Illumination
|
Eyepieces
|
Objectives
|
Stage
|
MC-40 |
Binocular
|
Infinity corrected vertical Koehler illuminator, focal length 200mm, with sliding rotatable polarizer. Filter Set: Blue Clear, Green Clear, Neutral Density ND8 and Polarizing filters in metal mounts. Port to accept FL150/12 flexible 36" (914.4mm) single arm fiber optic light guide. Flexible 36" (914.4mm) single arm fiber light guide for MA806. Focusing lens for FL150/12. Light source: 115V, 50-60Hz halogen lamp, 21V 150W. Light source: 230V, 50-60Hz halogen lamp, 21V 150W
|
Focusing eyepiece HWF10X-FF with cross-line reticule and set screw. High eyepoint eyepiece HWF10X, FN: 18, Eyepoint: 24mm
|
Plan Epi M5X, N.A. 0.10, infinity corrected, W.D. 20mm
Plan Epi M10X, N.A. 0.25, infinity corrected, W.D. 7.48mm Plan Epi M20X, N.A. 0.40, infinity corrected, W.D. 5.20mm Plan Epi M50X, N.A. 0.75, infinity corrected, W.D. 0.38mm |
Reflected light measuring stage: 150mm x 150mm with 50mm x 50mm X-Y movement with mounting brackets for digital micrometer heads
|
MC-40T |
Transmitted light measuring stage: 150mm x 150mm with 50mm x 50mm X-Y movement with glass stage plate and mounting brackets for digital micrometer heads
|
||||
MC-50 |
Trinocular
|
Reflected light measuring stage: 150mm x 150mm with 50mm x 50mm X-Y movement with mounting brackets for digital micrometer heads
|
|||
MC-50T |
Transmitted light measuring stage: 150mm x 150mm with 50mm x 50mm X-Y movement with glass stage plate and mounting brackets for digital micrometer heads
|
MC-50 & MC-50T SERIES BRIGHTFIELD AND SIMPLE POLARIZATION OBSERVATION METALLURGICAL MEASURING/TOOL MAKERS COMPOUND MICROSCOPES INFINITY CORRECTED OPTICAL SYSTEM F=200MM QUADRUPLE NOSEPIECE
Brightfield: The simplest of all the metallurgical optical microscopy illumination techniques. Sample illumination is transmitted or incident (i.e., illuminated from below or above and observed from above) white light and contrast in the sample is caused by absorbance of some of the transmitted or incident light in dense areas of the sample. Brightfield microscopy is the simplest of a range of techniques used for illumination of samples in light microscopes and its simplicity makes it a popular technique. The typical appearance of a brightfield microscopy image is dependent on the type of illumination technique used.
Simple Polarizing Light: Transverse wave light whose vibration possess direction is called polarized light. Light from an ordinary light source (natural light) that vibrates in random directions is called nonpolarized light. In contrast, while light with vertical vibration that travels within a single plane is called linearly polarized light, circularly polarized light and elliptically polarized light are types of light in which the vibration plane rotates forward. A polarizing plate (polarizing filter) or polarizing prism is often used as the device to change natural light to linearly polarized light.
The MC-50 & MC-50T Series is our trinocular precision measuring systems and are composed of high quality microscope components, precision X-Y stages and durable heavy duty stands. The MC-50 & MC-50T Series measuring microscopes are available with 2-axis and 3-axis electronic digital readouts in inches and metric. Operators can perform visual inspection and measurement of small items or components without complicated system setup. Mitutoyo Digimatic Micrometer heads have serial output for SPC applications. Fiber optics cable and light source with 21V, 150W are included.
Features:
•Computer Aided Design
•Ergonomically positioned coarse and fine focus controls
•Comfortable binocular viewing head with depolarizer
•150W Vertical Koehler Illuminator
•Brightfield and simple polariziation observation mode
•Focusing 10X eyepiece with cross-line reticle
•Planachromat Epi objectives, M5X, M10X, M20X, M50X included
•X and Y ports to accept Mitutoyo, MTI164-164 Digimatic Indicator - range 50mm (2”)
• “Z” axis mounting bracket to accept Mitutoyo MTI543-392 Digimatic Indicator and MA721 - 1.5” extension rod for 12.7mm (0.5”) range for “Z” axis measurement
•Blue Clear, Green Clear, Neutral Density, ND8 and Polarizing filters included
•Optional LED vertical koehler LED illuminator and transformer available
Model
|
Head
|
Illumination
|
Eyepieces
|
Objectives
|
Stage
|
MC-40 |
Binocular
|
Infinity corrected vertical Koehler illuminator, focal length 200mm, with sliding rotatable polarizer. Filter Set: Blue Clear, Green Clear, Neutral Density ND8 and Polarizing filters in metal mounts. Port to accept FL150/12 flexible 36" (914.4mm) single arm fiber optic light guide. Flexible 36" (914.4mm) single arm fiber light guide for MA806. Focusing lens for FL150/12. Light source: 115V, 50-60Hz halogen lamp, 21V 150W. Light source: 230V, 50-60Hz halogen lamp, 21V 150W
|
Focusing eyepiece HWF10X-FF with cross-line reticule and set screw. High eyepoint eyepiece HWF10X, FN: 18, Eyepoint: 24mm
|
Plan Epi M5X, N.A. 0.10, infinity corrected, W.D. 20mm
Plan Epi M10X, N.A. 0.25, infinity corrected, W.D. 7.48mm Plan Epi M20X, N.A. 0.40, infinity corrected, W.D. 5.20mm Plan Epi M50X, N.A. 0.75, infinity corrected, W.D. 0.38mm |
Reflected light measuring stage: 150mm x 150mm with 50mm x 50mm X-Y movement with mounting brackets for digital micrometer heads
|
MC-40T |
Transmitted light measuring stage: 150mm x 150mm with 50mm x 50mm X-Y movement with glass stage plate and mounting brackets for digital micrometer heads
|
||||
MC-50 |
Trinocular
|
Reflected light measuring stage: 150mm x 150mm with 50mm x 50mm X-Y movement with mounting brackets for digital micrometer heads
|
|||
MC-50T |
Transmitted light measuring stage: 150mm x 150mm with 50mm x 50mm X-Y movement with glass stage plate and mounting brackets for digital micrometer heads
|
Our Model MC-50 is a reflective light measuring microscope with erect image and trinocular head with depolarizer.
The Model MC-50T is an incident and transmitted light measuring microscope with erect image trinocular head. The MC-50T can also convert into a reflective light unit simply by moving the light guide from the base into the vertical illuminator tube.Our Model MC-40 is a reflective light measuring microscope with erect image and binocular head with depolarizer.
Included:
• MC-50T: Trinocular reflected and transmitted light fiber optic light guide with Koehler illuminator with sliding rotatable polarizer
• MA655/05: Erect image trinocular head with depolarizer
• MA413CF: Focusing eyepiece HWF10X-F with cross-line reticle and guide pin
• MA406: DIN HWF 10X widefield eyepiece, field No. 18
• MA870: Plan Achromat Epi Objective M5X, NA 0.10, infinity corrected, W.D. 20mm
• MA871: Plan Achromat Epi Objective M10X, NA 0.25, infinity corrected, W.D. 7.48mm
• MA872: Plan Achromat Epi Objective M20X, NA 0.40, infinity corrected, W.D. 5.20mm
• MA873: Plan Achromat Epi Objective M50X, NA 0.75, infinity corrected, W.D. 0.38mm
• MA806: Infinity corrected vertical Koehler illuminator with sliding rotatable polarizer Filter Set: Blue Clear, Green Clear, Neutral Density ND8 and Polarizing filter in metal mounts. Port to accept FT190/12 flexible 36” single arm fiber optic light guide
• FT190/12: Flexible 36” single arm light guide for MA806 illuminator
• FT190/115: FT190/115 Light Source 110/120V, 50-60Hz, Halogen lamp, 21V 150W
• FU-1010: Coaxial coarse and fine focus block with quadruple nosepiece
• MA475/05: Blue clear filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
• MA476: Green clear filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
• MA198: ND13 neutral density filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
• MA497: Polarizing filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
• MA729: Reflected & Transmitted light measuring stage: 150mm X 150mm with 50mm X-Y or 6” X 6” with 2” X-Y movement with glass stage plate and mounting brackets for digital micrometer heads
• MAC-11: Heavy duty stand with pillar and mounting bracket with 96.5mm diameter recess mounting surface hole
OPTIONAL COMPONENTS & ACCESSORIES BELOW
Digimatic Indicators:
• MTI164-164: Mitutoyo Digimatic Indicator for X-Y axis movement: Range 50mm (2”)( 2 Required)
• MTI543-392: Mitutoyo Digimatic Indicator (lug back) for Z axis movement: Range 12.7mm (0.5”) (1 Required) (MA721 is required)
• MA721: 1.5” (38 mm) Extension rod for Z axis digital indicator (Required for MTI543-392)
• MA807: Mounting brackets for digital “Z” axis indicator (Included with FU1010)
• MTI959149: Data Transfer Cable for MTI164-164 to MTI542-007A or MTIEH-542-072A
• MTI905689: Data Transfer Cable for MTI543-392 to MTI542-007A or MTIEH-542-072A
• MTI542-007A: EC Counter Assembly Type Display Unit
• MTIEH542-072A: EH Counter Multi-Function Display Unit
Viewing Heads:
• MA657/05: Erect image binocular head with depolarizer
Eyepieces:
• MA413CF: Focusing eyepiece HWF10X-F with cross-line reticle and guide pin
• MA584: Protractor eyepiece 10X
Plan EPI Objectives:
• MA874: Plan Achromat Epi Objective 100X, N.A. 0.90, W.D. 0.37mm, F.N. 24
LWD (Long working distance) Plan EPI Objectives:
• MA920: LWD Plan Achromat Epi Objective 20X, N.A. 0.40, W.D. 11.0 mm, F.N. 24
• MA921: LWD Plan Achromat Epi Objective 50X, N.A. 0.55, W.D. 7.5 mm, F.N. 24
Illuminator:
• MA806: Infinity corrected vertical Koehler illuminator with sliding rotatable polarizer Filter Set: Blue Clear, Green Clear, Neutral Density ND8 and Polarizing filter in metal mount Port to accept FL150/12 flexible 36” single arm fiber optic light guide
• MA806/LED: Infinity corrected vertical Koehler LED illuminator with sliding rotatable polarizer Filter Set: Blue Clear, Green Clear, Neutral Density ND8 and Polarizing filter in metal mount (MA927/05/LED Transformer needed)
• MA927/05/LED: Transformer only in metal case for MA806/LED vertical Koehler illuminator (input 100V -240V)
Eyepiece Micrometers:
• MA279: Cross-line reticle, 19mm diameter
• MA539: Cross-line with 0.1mm graduations, 19mm diameter
Stage Micrometers:
• MA285: Stage micrometer, 1mm divided into 100 units, each unit 0.01mm
• MA286: Stage micrometer, 0.04” divided into 100 units, each unit 0.001inch
• MA292: Metal stage micrometer, 0.01mm, for reflected light
Bulbs:
• FL150/70: Spare bulb, 21V/150W (For FL150/100 or FL150/200)
Miscellaneous:
• MA569: Replacement glass stage plate for MA729 transmitted light stage
Double click to read at full screen
Download Brochure (PDF)
Double click to read at full screen
Download Manual (PDF)
Double click to read at full screen
Download Brochure (PDF)
Double click to read at full screen
Download Brochure (PDF)