MT5300ED LED Ergonomic Trinocular Dermatology Microscope

Meiji Techno's laboratory grade upright microscope line is the new and cost-effective MT5000 Series Biological Microscopes. The MT5000 Series employs all new and improved U.Plan optics. Meiji Techno's ICOS™ (Infinity Corrected Optical System) makes the study of mounted specimens fast and easy while delivering an excellent cost-to-performance ratio. The demand for a reliable Dermatology Microscope has been growing in popularity, with new treatments for skin cancer are appearing and evolving rapidly in recent years. However, one surgical technique has more than stood the test of time. Developed by Dr. Frederick Mohs in the 1930s, Mohs micrographic surgery has, with a few refinements, come to be embraced over the past decade by an increasing number of surgeons for an ever-widening variety of skin cancers. Mohs specialist are in demand of a microscope that will help them identify cancer at every stage of growth. Mohs surgery has come to be accepted as the single most effective technique for removing Basal Cell Carcinomas (BCC) and Squamous Cell Carcinomas(SCCs), the two most common skin cancers. It accomplishes the nifty trick of sparing the greatest amount of healthy tissue while also most completely expunging cancer cells; cure rates for BCC and SCC are an unparalleled 98 percent or higher with Mohs, significantly better than the rates for standard excision or any other accepted method. The reason for the technique's success is its simple. Mohs differs from other techniques in that microscopic examination of all excised tissues occurs during rather than after the surgery, thereby eliminating the need to "estimate" how far out or deep the roots of the skin cancer go. This allows the Mohs surgeon to remove all of the cancer cells while sparing as much normal tissue as possible. The procedure entails removing one thin layer of tissue at a time; as each layer is removed, its margins are studied under a microscope for the presence of cancer cells. If the margins are cancer-free, the surgery is ended. If not, more tissue is removed from the margin where the cancer cells were found, and the procedure is repeated until all the margins of the final tissue sample examined are clear of cancer. In this way, Mohs surgery eliminates the guesswork in skin cancer removal, producing the best therapeutic and cosmetic results. In the past, Mohs was rarely chosen for Melanoma surgery for fear that some microscopic melanoma cells might be missed and end up spreading around the body (metastasizing). However, efforts to improve the Mohs surgeon's ability to identify melanoma cells have led to special stains that highlight these cells, making them much easier to see under the microscope. Thus, more Mohs surgeons are now using this procedure with certain melanomas. With the rates for melanoma and other skin cancers continuing to increase, Mohs will play an ever more important role in the coming decades. The MT5000D Series is a useful tool in helping bridge the gap in helping find a cure to this curable cancer. 


made in japan


Locate a DealerGet a Quote


ceisorohs

Includes:
   • MT5300ED: Ergonomic Trinocular Brightfield Dermatology Compound microscope with Bright LED Koehler illumination with quintuple nosepiece and auto voltage sensing power supply
   • MA957: Ergonomic tilting binocular head- adjustable vertically from 10 to 50 degrees (30.mm I.D. eyetube)
   • MA958: Photo / video attachment with sliding 80/20 beam-splitter 

 


   • MA817 (x 2):SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm


   • MA1022: Plan Apochromat Objective 1.25X, N.A. 0.04, W.D. 3.7 mm, F.N. 24
   • MA831: U. Plan Objective 4X, N.A 0.10, W.D. 25.8mm, F.N. 24
   • MA832: U. Plan Objective 10X, N.A. 0.25, W.D. 10.7mm, F.N. 244
   • MA833: U. Plan Objective 20X, N.A. 0.40, W.D. 7.29mm, F.N. 24
   • MA834: U. Plan Objective 40X, N.A. 0.65, W.D. 0.5mm, F.N. 24

 


   • MA976: Abbe condenser, N.A. 0.90 with swing out top lens, iris diaphragm and dovetail mount


   • MA918R:Ceramic coated flat-top stage, 190mm x 140mm, with 80mm x 52mm X-Y movement and right hand  drop-down coaxial controls


   • MA598: Attachable finger assembly for MA917R and MA917L
   • MA809/10: Removable AC Electric cord with plug for 115V models
   • LED/SP-1: 3W LED, 5500K color temperature
   • MA929: Spare fuse 0.5A for MT5000 LED Illuminator
   • MA809/10: Removable AC Electric cord with plug for 115V models
   • MA701: Dust Cover for MT5000
   • Manual: MT5000 Meiji Techno Instruction Manual
   • Warranty: Limited Lifetime Warranty Card

OPTIONAL CAMERA ACCESSORIES

CAMERAS (OPTIONAL)
Model HD1000-LITE HD1500T HD1500MET HD1500MET-AF
     

Type HDMI/USB 2.0

HDMI/USB 2.0

Basic Measurement Features

HDMI/USB 2.0

Metrics Measurement Features

HDMI/USB 2.0

Auto-focusing/Z stack & stitching

Version Color Color Color Color
Mega Pixels 5MP 2-6MP 2-6MP 2-6MP
Resolution 2592 x 1944 3264 x 1840 Static
1920 x 1080 Dynamic
3264 x 1840 Static
1920 x 1080 Dynamic
3264 x 1840 Static
1920 x 1080 Dynamic
Frame Rate (FPS) 15fps by HDMI
15fps by USB 2.0
60fps by HDMI
30fps by USB 2.0
60fps by HDMI
30fps by USB 2.0
60fps by HDMI
30fps by USB 2.0
Sensor 1/2.5" CMOS 1/2.8" CMOS 1/2.8" CMOS 1/2.8" CMOS
C-mount 0.3X 0.3X 0.3X 0.3X

 

CAMERAS WITH MONITORS (OPTIONAL)
Model HD1000-LITE-M HD1500TM HD1500MET-M HD1500MET-M-AF
 
Type HDMI/USB 2.0

HDMI/USB 2.0

Basic Measurement Features

HDMI/USB 2.0

Metrics Measurement Features

HDMI/USB 2.0

Auto-focusing/Z stack & stitching

Monitor Size 11.8" 11.8" 11.8" 11.8"
Version Color Color Color Color
Mega Pixels 5MP 2-6MP 2-6MP 2-6MP
Resolution 2592 x 1944 3264 x 1840 Static
1920 x 1080 Dynamic
3264 x 1840 Static
1920 x 1080 Dynamic
3264 x 1840 Static
1920 x 1080 Dynamic
Frame Rate (FPS) 15fps by HDMI
15fps by USB 2.0
60fps by HDMI
30fps by USB 2.0
60fps by HDMI
30fps by USB 2.0
60fps by HDMI
30fps by USB 2.0
Sensor 1/2.5" CMOS 1/2.8" CMOS 1/2.8" CMOS 1/2.8" CMOS
C-mount 0.3X 0.3X 0.3X 0.3X
Product Information:
   • Manufactured: 100% MADE IN JAPAN
   • Warranty: LIMITED LIFETIME WARRANTY
   • Customer Support: 1-(800) 832-0060 (U.S.A Based)

Package Information:
   • Weight: 34 lbs (15.4kg)
   • Box Size: 16 x 14 x 21 inches
   • Footprint: 263mm (D) x 176mm (W)
   • Binocular head type: 390 mm(D) x 410mm (H) x 210mm(W) (8.0kg)( 29.0 lbs)
   • Trinocular head type: 390 mm(D) x 465mm(H) x 210mm(W) (8.7Kg)( 30.0 lbs)
   • Binocular Ergonomic head type: 390 mm(D) x 483mm (H) x 210mm(W) (8.4kg)(31 lbs)
   • Trinocular Ergonomic head type: 390 mm(D) x 533mm(H) x 210mm(W) (8.9Kg)(33 lbs)

Details

The MT5000D Microscopes features include:

  • Compact Space Saving Footprint design with ergonomics in mind
  • Infinity Corrected Optical System (ICOS™) with all newly designed optics
  • Comfortable Siedentopf-type Binocular and Trinocular Viewing heads
  • Optional Ergonomic tilting binocular head- Adjustable vertically from 10°to 50° degrees
  • Ceramic Coated Stage with Ergonomically Placed Low Position Drop down Control
  • Low Positioned Ergonomic Coaxial Focus Control
  • Smooth Operating Ergonomic Quintuple Nosepiece
  • Plan Apo 1.25X objective is used with a specialized Abbe condenser
  • Plan Apo 4X, 10X, 20X and 40X is included
  • 2.5X U. Plan objective is available
  • Brightfield Observation mode
  • Super Bright LED Koehler illumination, lambertian design
  • Abbe Condensers with swing out top lens
  • Built-in iris diaphragm
  • Integrated Automatic Voltage Sensing Power Supply with localized power cord
  • Wide Range of Filters and Accessories

Brightfield:
The simplest of all the optical microscopy illumination techniques. Sample illumination is transmitted (i.e., illuminated from below and observed from above) white light and contrast in the sample is caused by absorbance of some of the transmitted light in dense areas of the sample. Brightfield microscopy is the simplest of a range of techniques used for illumination of samples in light microscopes and its simplicity makes it a popular technique. The typical appearance of a brightfield microscopy image is a dark sample on a bright background.

Dermatology:
The demand for a reliable Dermatology Microscope has been growing in popularity, with new treatments for skin cancer are appearing and evolving rapidly in recent years. Mohs surgery, also known as chemosurgery, is the most commonly used in the study with dermatology. Mohs surgery has come to be accepted as the single most effective technique for removing Basal Cell Carcinomas (BCC) and Squamous Cell Carcinomas(SCCs), the two most common skin cancers. It accomplishes the nifty trick of sparing the greatest amount of healthy tissue while also most completely expunging cancer cells; cure rates for BCC and SCC are an unparalleled 98 percent or higher with Mohs, significantly better than the rates for standard excision or any other accepted method.

The MT5000D Series are used to view prepared thin slices of thin tissue, which have a common setup that utilizes lower magnification objective lenses 4X, 10X, 20X and 40X. The lowest magnifications are typically used most frequently. When using a dermatology microscope the samples must be sliced thinly in order to allow the physician to view it clearly.

VIEWING HEADS
Model MA815 is the Siedentopf-type binocular head and Model MA816 is the trinocular head for camera integration. Each head has the eyetubes inclined at 30 degrees with the left eyetube having graduated diopter settings. The interpupillary distance is adjustable between 53mm - 75mm. An 80/20 beamsplitter for the trinocular tube can be engaged for photo work. (100% to eyetubes or 80% to phototube & 20% to the eyetube.) The optional MA957, Ergonomic Binocular Viewing Head, has the inclination adjustable from 10 to 50 degrees to fit users of different heights. The Ergonomic Trinocular model comes with the MA958, photo/video attachment with sliding 80/20 beam-splitter (Included in MT5300ED).

EYEPIECES
10X Super Widefield High Eyepoint eyepieces F.N.22 are standard, and 15X and 20X eyepieces are available as an option. A Super Widefield High Eyepoint 10X focusable eyepiece that accepts 25mm reticules is also available.

OBJECTIVE CHANGER
Quintuple nosepiece provides effortless objective changes with smooth-operating, ball bearing mounted.

OBJECTIVES
Meiji Techno America offers an assortment of Planachromat Infinity Corrected (ICOS) objectives for Brightfield observation modes.

STAGE
Ceramic coated standard right-handed or optional left-handed controls, flat top stage 191mm x 140mm with travel: 80mm(X) x 52mm(Y). Ergonomically positioned coaxial drop down controls. Available with motorized focus and stage controls.

CONDENSER
New design centerable Abbe 1.25 N.A. Condenser with built-in iris diaphragm in dovetail mount.

ILLUMINATION
Powerful white LED illumination provides enhanced image quality and brightness for the observation of specimens and photomicroscopy.

PHOTOMICROGRAPHY
Meiji Techno offers a broad range of digital video cameras which offers excellent sensitivity, high resolution and a wide dynamic range for the most demanding brightfield and darkfield microscopy applications including clinical pathology and cytology, life sciences and geology. Some models has included software, that can preview and capture still shots and live videos to a PC or Mac with USB port or HDMI connectivity.

Details

Biological TerminologyModel
Model
Head
Illumination
Eyepieces
Objectives
Stage
Condenser

MT5200D

Binocular
LED Illumination
 
SWH10x FN22
Plan Apo 1.25x U. Plan 4x, 10x, 20x, 40x
Ceramic Coated Fixed flat-top left or right-handed controls
Abbe NA 0.90 with swing out top lens

MT5200ED

Ergonomic Binocular

MT5300D

Trinocular

MT5300ED

Ergonomic Trinocular

Components & Accessories

Included:
   • MT5300ED: Ergonomic Trinocular Brightfield Dermatology Compound microscope with Bright LED Koehler illumination with quintuple nosepiece and auto voltage sensing power supply
   • MA957: Ergonomic tilting binocular head- adjustable vertically from 10 to 50 degrees (30.mm I.D. eyetube)
   • MA958: Photo / video attachment with sliding 80/20 beam-splitter 
   • MA817 (x 2):SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
   • MA1022: Plan Apochromat Objective 1.25X, N.A. 0.04, W.D. 3.7 mm, F.N. 24
   • MA831: U. Plan Objective 4X, N.A 0.10, W.D. 25.8mm, F.N. 24
   • MA832: U. Plan Objective 10X, N.A. 0.25, W.D. 10.7mm, F.N. 24
   • MA833: U. Plan Objective 20X, N.A. 0.40, W.D. 7.29mm, F.N. 24
   • MA834: U. Plan Objective 40X, N.A. 0.65, W.D. 0.5mm, F.N. 24
   • MA976: Abbe condenser, N.A. 0.90 with swing out top lens, iris diaphragm and dovetail mount 
   • MA918R:Ceramic coated flat-top stage, 190mm x 140mm, with 80mm x 52mm X-Y movement and right hand  drop-down coaxial controls
   • MA598: Attachable finger assembly for MA917R and MA917L
   • MA809/10: Removable AC Electric cord with plug for 115V models
   • LED/SP-1: 3W LED, 5500K color temperature
   • MA929: Spare fuse 0.5A for MT5000 LED Illuminator
   • MA809/10: Removable AC Electric cord with plug for 115V models
   • MA701: Dust Cover for MT5000

OPTIONAL COMPONENTS & ACCESSORIES BELOW

Viewing Heads:

   • MA815: Binocular head siedentopt type, I.P. adjustment 53mm to 75mm, graduated diopter on left eyetube (30.0 mm I.D. eyetube) Inclined at 30 degrees Inverted Image (Included in Models MT5200D)
   • MA957: Ergonomic tilting binocular head - Adjustable vertically from 10 to 50 degrees (30.0 mm I.D. eyetube) Erect image (Included in MT5200EL & MT5200EH)

Photo/Video Attachment:
   • MA958: Photo / video attachment with sliding 80/20 beam-splitter. For use with video or digital cameras when MA957/05 ergonomic head is used (Included in all Ergonomic Trinocular models)

Eyepieces:
   • MA407/05: KHW10X-F Compensation Focusing eyepiece, Field No. 20, Tube O.D. 23.2mm (each)
   • MA200: Eyeshield for MA407 KHW10X eyepiece (each)
   • MA408:HWF15X Widefield eyepiece, Field No. 12.2, Tube O.D. 23.2mm (each) (no reticle mount)
   • MA409:HWF20X Widefield eyepiece, Field No. 9, Tube O.D. 23.2mm (each) (no reticle mount)

Objectives:
   • MA818: SWH 15X Widefield high eyepoint eyepiece, Field No. 16.0, tube O.D. 30.0 mm (each) (19mm reticle mount)
   • MA819: SWH 20X Widefield high eyepoint eyepiece, Field No. 12.0, tube O.D. 30.0 mm (each) (19mm reticle mount)
   • MA830: U. Plan Objective 2.5X, N.A. 0.07, W.D. 5.7mm, F.N. 24
   • MA835: U. Plan Objective 50X oil, N.A.0.87, W.D. 0.28 mm, F.N. 24
   • MA837: U. Plan Objective 100X oil, N.A. 1.25, W.D. 0.23mm, F.N. 24 (For use with MA910 condenser)

Brightfield Condenser:
   • MA910: Abbe condenser, N.A. 1.25 with iris diaphragm and dove-tail mount (Optional for use with 100X objective)

Filters:
   • MA858/05: ND 25 Neutral density filter, 44.0mm diameter, unmounted
   • MA857/05: Green filter, clear, 44.0mm diameter, unmounted (Included in all phase models)
   • MA856/05: LB100 Blue Clear filter 44.0mm diameter, unmounted

Stages:
   • MA918L: Ceramic coated flat-top stage, 190mm x 140mm with 80mm x 52mm X-Y movement, and left hand drop-down coaxial controls
   • MA598: Attachable finger assembly for MA917R and MA917L (Included with MA917R & MA917L)
   • MA676: Attachable clinical finger assembly for MA917R and MA917L

Eyepiece Micrometers (21mm diameter for use with MA407 eyepiece)
   • MA542: Cross-line reticle with 0.1mm graduations, 25mm diameter
   • MA506: 10mm line divided into 100 units, 25mm diameter 
   • MA509: 5mm line divided into 100 units, 25mm diameter
   • MA524: 10mm square divided into 400 parts, each square 0.5 mm, 25mm diameter 
   • MA510: 10mm square divided into 100 parts, each square 1.0 mm, 25mm diameter

Stage Micrometers
   • MA285: 1mm divided into 100 units, 0.01mm
   • MA286: 0.04” divided into 40 units, 0.001”

Replacement Blubs and Fuse
   • LED/SP-1: 3W LED, 5500K color temperature (For use wtih MT5000L LED Series models)
   • MA929: Spare Fuse 0.5A for MT5000 LED Illuminator

Miscellaneous
   • MA977: Eye level riser for MT Series stands


Double click to read at full screen
Download Brochure (PDF)