IVF-13TRH with FT192 - Trinocular In-vitro Fertilization System Stereo Microscopes

The IVF Series includes a digital microscope that is combined with a HDMI camera and amini HDMI 11.6" monitor mounted above the microscope head for easy still shot imaging and video capture. Images are save directly in the included SD card. There is a transmitted brightfield light base with a rotatable and sliding mirror and a built-in cool LED lightsource. In addition to the built-in transmitted light, it comes equipped with a Fiber Optic Dual Gooseneck Incident (top light) 150W, 6" –7" of Working Distance which provides adequate ergonomics and manipulation of the embryo. Meiji Techno IVF Series provides a preconfigured out-of-the box solution for researchers and medical doctors specializing in IVF, ART, IVD, PGS, PGD, ICSI, FET procedures. The high-quality optics provide a magnification of up to 7X–140X with the provided 10X or 20X paired eyepieces to visualize even the tiniest details on your embryo sample. The built-in HD camera provides a full HD live image with up to 60fps and a capture resolution of 6 mega pixels (MP). The IVF Series from Meiji Techno America can be used as a stand-alone unit without the need for a computer, but has the capability to be attached to a PC via USB 2.0 to use the included measurement/ annotation software suite.

IVF-13TRH Consists of the following items:

EMZ-13TRH Info:


The EMZ-13TRH is a new and improved high eyepoint model with an eye relief of 20.9mm designed for microscopists and for people who wear glasses. It is specially designed to give the user more clearance between their eyes and the microscope. The high eyepoint models also use a newly designed eyepiece with a wider designed lens to compliment the high eyepoint models (MA522 10X, MA818 15X, MA819 20X). Optional rubber eye guards (MA906) are also available.

Body: Binocular, Rotatable 360°, Cast Aluminum Alloy Construction 
Zoom Ratio: 7:1  
Zoom Range: 1x - 7x 
Zoom Knobs Markings: 1, 1.2, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 7
Zoom Control: Dual, graduated, bilateral 
Magnification: 10x - 70x  (10x eyepieces) 
Objective Lens: Brass Construction
Field of View: 23mm - 3.2mm 
Working distance: 90mm 
Eyetube Inclination: 45° 
Eyepieces: High Eyepoint 10x, (MA522- Paired) (required)
Interpupillary Distance: 54mm - 75mm 
Dioptric Adjustment: Dual (+/- 5 diopters) 
Extended Mag Range: 3x - 420x (With auxiliary lenses and eyepieces) 
Extended Working Distances: 32mm - 230mm (With auxiliary lenses and eyepieces) 
Auxiliary Lenses: 0.3x (252mm), 0.44x (181mm), 0.5x (150mm), 0.75x (97mm), 1.5x (49mm), and 2x (34mm) (optional)
Mounting: Fits 84.5mm Diameter Focus Holders
Manufacturer: MADE IN JAPAN
Warranty: LIMITED LIFETIME WARRANTY

MA522 Info:

ma522


Super Widefield Eyepiece, high eye point 10X (paired) (With 25mm reticle mount) (Fits EMZ-5H, EMZ-5TRH, EMZ-8TRH, EMZ-10H models only)


MA504 Info:

ma504

Super Widefield High Eyepoint Eyepiece 20X (pair) Field No. 11.5, with 30.5mm O.D. (Outer Diameter), with 25mm reticle mount. This 20X Super Widefield Eyepiece is designed to fit our Meiji Techno models EMZ (Zoom Series), EMT (Turret Series), EMF( Fixed Series), not compatible with High Eyepoint Models.

MA517 Info:

Auxiliary Lens 0.5X W.D. 150mm

FC Info:


FC Coarse and Fine Focus Block/Holder focus holder is for high magnification applications where precise fine focus adjustment is required. Rack and pinion mount allows smooth and precise focusing over 33mm of travel. Coarse and fine focus mechanism incorporates a slip clutch and tension adjustment. Fits 20mm diameter, 82mm long mounting post (FC11 adapter is required for mounting to the 71mm long posts on our S-4100, S-4200, and S-4500 stands). The 84.2mm diameter opening accepts all EM Series stereo bodies.

BD-M-LED Info:

The EM Series stereoscopes can be mounted on the BD-M-LED stand for transmitted Brightfield / Darkfield LED illumination. This features a rotatable sliding mirror which also slides back and forth to direct the light at an appropriate angle. This product is ideal for many biological applications but works also for gemology due to the adjustable angled illumination with the rotatable sliding mirror. This includes a 20mm post (Requires F focus block or any 20mm focus block.) Base Dimensions: 330mm (13") wide by 280mm (11") deep by 85mm (3.37") high.   

   • Brightfield/Darkfield pole type stand
   • 94.5mm clear glass stage plate 
   • Automatic voltage sensing power supply (110v-220v) 
   • Wide surface stand that can accommodate 3-4 petri dishes 
   • Front slope for comfortable hand placement 
   • LED rheostat intensity control  
   • Rotatable and sliding mirror 
   • Locking ring for mirror angle placement 
   • Accepts 20mm focus blocks such as the F, FX, FC models 
   • Can accommodate EMZ-Zoom, EMT-Turret and EMF-Fixed stereo microscope bodies

FT192 Info:


Variable intensity 150W quartz halogen light source with 60mm I.D. annular light guide fits all RZ and EMZ stereo microscopes; adapter required for EMT and EMF stereos. All metal construction. UL-1571 and CE/CSA 2001 compliant. Available in 110V and 220/240V CE approved models. Two Year Limited Warranty. Color temperature: 3200K.

Product Information:
   • Warranty: 2 Year Warranty
   • Customer Support: 1-(800) 832-0060 (U.S.A Based)

Package Information:
   • Weight: 9 lbs (4.0kg)
   • Box Size: 15 x 15 x 9 inches

Technical Information

Input Voltage: 

 120 V AC50/60Hz

Output Voltage: 

 0-21 Volts

Rated Power Output (max): 

 200 Watts

Fuse Type: 

 2,5 Amp Slow blow

Temperature Range (Operating Storage): 

 0 to 45 C | -25 to 85 C

Fiber Optic Interface: 

 15 mm or 25 mm

Relative humidity, Non
Condensing: 

 5% to 95%

Vibrations: 

 10-500Hz 2G 10min./cycle. Period for 60 min (Each axis)

Dimension/Weight: 

 8” (W) X 4.75” (H) X 7” (D) (13.5 lbs)


MA151/35/03 Info:

ma151/35/03

C-mount adapter with 0.3 lens, accepts 21mm reticle (Slips over top of existing photo tube - For 1/3" CCD)

Camera Chip Size
Suggested Adapter
1/4"
0.265 or 0.3X
1/3"
0.3X
1/2"
0.45X, 0.5X or 0.6X
1/1.8"
0.45X, 0.5X or 0.6X
2/3"
0.7X
1"
1.0X

HD1500TM Info:

HD1500TM Includes: 
   • HD1500TM Camera
   • HDMI Cable
   • USB Cable
   • 12V AC/DC Power adapter
   • SD Card
   • Mouse
   • Application Software ISCapture
   • Packing Box

Package Information:

   • 5lbs
   • 12 x 10 x 4 inches

NEW: BUILT-IN MOUSE CONTROL CAMERA 
The significant innovation of the HD15000T is making the software implant inside the camera. This forward thinking feature frees users from cumbersone computers and annoying buttons. You can control the camera by only a mouse directly.

01

Videos of the camera in action with our microscopes:
Brief overview with the compare feature
With Darkfield microscopy.

 

PERFECT COLOR REPRODUCTION 
Meiji Techno's HD technology offers true-to-life reproduction oh image color. What you see on the monitor is what you get from the microscope eyepiece. No compressed date transmission, resulting in scientific-grade images.

02

1080P 60FPS FULL FRAME RATES
With 60fps at 1080p, the HD1500T presents a perfect combination of outstanding resolution and frame rate. This allows the user to fluently manipulate the live images without any lags.

03

HDMI+USB 2.0+SD OUTPUT
Multiple output options are available for this powerful HDMI camera. HDMI 1080P, USB 2.0, or SD memory card can be used individually or all three SIMULTANEOUSLY.

03

DUAL FPGA PROCESSORS
With an innovative Dual FPGA processor architecture design, FPGA1 for image quality processing and FPGA2 for image output control, you get a high-speed preview without sacrificing image quality. It is the most powerful camera you deserve to have.

05

SMART PRESENTATION
Camera parameters such as exposure time, white balance, and gain are designed by default to operate automatically. Automatic optimum configuration is expected to be done in 0.015 seconds, and you'll find that the camera is easily managed from the start.

06

ADVANCED PARAMETER SETTING
For users with specific requirements, the camera is designed with parameter setting buttons that enable manual adjustment of white balance, gain, saturation, Gamma and screen freeze.

07

PC TO TV
Images are displayable on PCs and HDMI-installed TVs. All parameters can be controlled by the computer to adjust them to actual situations. This is advantageous in teaching and meeting applications.

08

On-board Video Saving
The SD card can save not only still images, but also dynamic images in 720P color definition, such that motion trails are recorded in fast speed and intact form.

09

LOW LIGHT SENSITIVITY
Thanks to its highly sensitive sensor, the HD1500T is capable of capturing low-light images rapidly. In darkfield imaging and even fluorescence, it will automatically increase the sensitivity, presenting low light images with clarity in high-speed preview mode.

10

Details

In-Vitro Fertilization (IVF)
While "in vitro fertilization" literally refers to the fertilization of an oocyte (egg) with sperm outside of the body, the phrase is now used to refer to the entire process by which a woman becomes pregnant using assisted reproductive technology (ART), including ovarian stimulation, oocyte retrieval, in vitro fertilization, embryo transfer and embryo/oocyte cryopreservation

Intracytoplasmic Sperm Injection (ICSI)
Intracytoplasmic sperm injection (ICSI) is a vital adjunct to in vitro fertilization that has facilitated hundreds of thousands of pregnancies around the world. ICSI is a procedure in which a single sperm is injected directly into an egg to achieve fertilization. The resulting embryo(s) are then incubated for three or five days before transfer to the patient, or may be cryopreserved. ICSI is commonly used to treat male factor infertility due to low sperm count, poor sperm movement or abnormally shaped sperm. ICSI is also used to fertilize oocytes that have been cryopreserved as part of a fertility preservation treatment (“egg freezing”), and in conjunction with testicular sperm extraction (TESE) and PGD/PGS.

Preimplantation Genetic Diagnosis (PGD)
PGD can identify an embryo unaffected by heritable genetic disease before transfer to the uterus, the last step of IVF. Embryos or oocytes are biopsied with a microscopic needle. The removed cell or cells are then analyzed to detect genetic mutations that cause diseases. Almost any single-gene disease for which mutations have been identified can be diagnosed in an oocyte or embryo using PGD. Patients who have a question about specific conditions are encouraged to contact CRM to set up an initial consultation with a physician to discuss IVF with PGD. PGD can greatly increase parents’ chances of having a child that is unaffected by heritable genetic disease, including sex-linked diseases, cystic fibrosis and hundreds of other disorders.

Preimplantation Genetic Screening (PGS)
The gain or loss of an entire chromosome or chromosome segment occurs frequently during the maturation of eggs and sperm as well as during early embryonic (post-fertilization) development. Chromosomal abnormality, or aneuploidy, in eggs also increases significantly as women age. Such abnormalities may cause a pregnancy to be miscarried or severe health problems in the child if the pregnancy goes to term

Frozen Embryo Transfer (FET)
Healthy embryos resulting from an IVF cycle but not transferred to the patient at the end of the cycle can be cryopreserved and stored. When the patient is ready to have another child, her embryo(s) are thawed and transferred to her uterus at the appropriate point in her menstrual cycle. This process is called a frozen embryo transfer (FET). A patient preparing for an FET has blood testing and ultrasound scans that enable her physician to identify the appropriate point in the patient’s cycle to transfer the embryo(s). Some FET patients may also take hormone medication to prepare for the transfer.

Meiji Techno America offers a large variety of configured and customizable solutions to meet your imaging needs and provides tailored solutions for your budget and application. Enhanced ergonomics and worker comfort for In-Vitro (IVF) achieves a higher throughput and better workflow with comfort and accuracy in mind for higher efficiency

Details

Modular Flexibility: 
IVF Series zoom stereo microscopes are most the rugged microscopes from Japan and tailored to fit the needs of each and every customer. Modular design enables the user to engineer their own custom solution for virtually any application, selecting components from the widest range bodies, stands, eyepieces, supplementary lenses, illuminators, camera adapters, and accessory components available in the microscope industry today. 

Superb Optics: 
Multi-coated optical components, free form chromatic and spherical aberration, provide crystal-clear, high resolution images. The Greenough optical design provides superior erect, unreversed, stereoscopic images, rich in contrast, brightness and correct in their original color. Excellent depth of field and a flat image rendition are also characteristic of the IVF Series product line.

Rugged Dependability: 
All-metal aluminum alloy microscope bodies and components with chemical resistant finishes guarantee stability and rugged dependability for a lifetime of day-in and day-out use. Superior craftsmanship, quality components and materials result in long-lasting, high-performance products.

Components & Accessories

Eyepieces Stands Focus Blocks Holder Auxiliary Lens Illuminators
Eyepieces (High Eyepoint) Stands Focus Blocks Holder Auxiliary Lenses Illuminators
Micrometer Lens Stages Polarizing Accessories Protective Glass Covers Cameras
Micrometer Lens Stages Polarizing Accessories Protective Glass Covers Microscopy Cameras
C" Mounts/Camera Adapters Filters C" Mounts/Camera Adapters  
C" Mounts/Camera
Adapters
Filters Accessories

Download Camera Driver (ZIP)
Download TCapture Software (ZIP)


 


Double click to read at full screen
Download Brochure (PDF)


 


Double click to read at full screen
Download Manual (PDF)


 


Double click to read at full screen
Download Manual (PDF)


 


Double click to read at full screen
Download Software Manual (PDF)


 


Double click to read at full screen
Download Menu Quick Guide (PDF)


 


Double click to read at full screen
Download Calibrate Guide (PDF)


 


Double click to read at full screen
Download TCapture Software Manual (PDF)