MT4300EL-HD1500TM/0.3 LED 40X-1000X Biological Compound Ergonomic Binocular Brightfield with Infinity Corrected 4X, 10X, 40X, 100X with HD Camera Monitor (HD1500TM)

NEW OBJECTIVES

This configuration is called the MT4300EL-HD1500TM/0.3 as it is configured with Meiji Techno's newly designed Upright Trinocular Ergonomic Biological LED Compound called the MT4300EL and a HD camera monitor called the HD1500TM. Equipped with newly upgraded U. Plan Infinity Corrected 4X,10X 40X and 100X oil objectives. Ergonomically designed head with the ability to tilt precisely 10°to 50° degrees. Manufactured in Japan and simple to use stage and coarse and fine controls. To meet the demands of researchers and clinical laboratory specialists.

Meiji Techno has reviewed all aspects of microscope usability to develop the MT4300EL Trinocular ergonomic microscope, which provides functionality with operational ease. Viewing high quality images, sample changing and photomicroscopy are all conducted with ergonomics in mind. High luminescent LED illumination reduces need for frequent bulb replacement. The MT4300EL is designed for Brightfield observation and rugged quality as you would expect from a Japanese made microscope. Various imaging techniques are available with different models in this series

The HD1500TM’s display features full HD (1080x1920) resolution and provides high fidelity images from the HD1500TM with a refresh rate of 60 frames per second. Included with the display is a mounting kit that allows the display to be mounted directly on the HD1500TM. The incredibly disruptive aspect of the display is that when used with the (supplied) mouse, the user can access menus that provide all the features of the camera such as exposure, white balance, gamma etc plus allow the user to save images and videos to the cameras removable SD card for subsequent offline analysis. All this is achieved without the need for a PC.

NOTE for the HD1500TM:
• 6MP Still resolution 3264x1836
• 2MP Live video 1920x1080 60 fps (frames per second) via HDMI
• 2MP Live video 1920x1080 30 fps (frames per second) via USB2.0
made in japan


Locate a DealerGet a Quote


ceisorohs

Model
Head
Illumination
Eyepieces
Objectives
Stage
Condenser

MT4200L

Binocular
LED Illumination
 
KHW10x FN20
U. Plan 4x, 10x, 40x, 100x oil
Fixed flat-top left or right-handed controls
Abbe NA 1.25 with iris in dovetail mount

MT4200EL

Ergonomic Binocular

MT4300L

Trinocular

MT4300EL

Ergonomic Trinocular

MT4200H

Binocular
Koehler 30W halogen

MT4200EH

Ergonomic Binocular

MT4300H

Trinocular

MT4300EL

Ergonomic Trinocular

MT4300EL-HD1500MET-M/0.3 Trinocular Ergonomic Brightfield Biological Laboratory Series is one of our most rugged fully equipped microscope systems from Japan . To meet the demands of researchers and clinical laboratory specialists. It offers many high performance. The MT4300EL Series microscopes feature a new computer engineered rigid frame that incorporates low positioned coaxial coarse/fine focus controls and ergonomic stage design for maximum efficiency and comfort while providing and extremely stable platform. The cast alluminum alloy metal stand has a chemical resistant finish and is the most rugged, durable finish in the market today. Equipped tension adjustment controls and a built in stage stop lever to protect the specimen and objectives from accidental damage during use. The MT4300EL Series offers an outstanding range of features and optical performance with an emphasis on all newly engineered high performance optics based on Meiji Techno’s ICOS™ Optical System (Infinity Corrected Optical System F=200mm) The new tilting ergonomic Trinocular head with Japanese optics, provide exceptionally bright, crisp images with good color rendition and superior flat fields of view. A modular design facilitates attachment of a variety of accessories such as CMOS/CCD HDMI video cameras , and all types of 35mm Digital SLR Cameras in the market today can be attached easily with the proper adapter set. The MT4300EL Series Microscopes offer crisp, distortion free, high resolution images in multiple modes of operation, Contrast methods available include: Brightfield and Phase Contrast. Limited Lifetime The MT4300EL Biological Microscope is a versatile and modular ergonomic system designed to accept a wide variety of optional accessories and is backed by Meiji Techno’s Limited Lifetime Warranty.

Includes:
   • MT4300EL: The  MT4300EL Research Series is ergonomically designed, precisely manufactured in Japan and simple to use, this upright Ergonomic Trinocular Biological Compound LED Microscope provides versatility and high quality images for Brightfield observation as you would expect from a Japanese Made Microscope
   • HD1500TM: The HD1500TM’s display features full HD (1080x1920) resolution and provides high fidelity images from the HD1500TM with a refresh rate of 60 frames per second. Included with the display is a mounting kit that allows the display to be mounted directly on the HD1500TM. 
   • MA151/35/03: C-mount adapter with 0.3X lens

MICROSCOPE HEAD - Siedentopf Binocular tube Accomodates Simple Eyepoint Adjustment
   • MA816/05: Ergonomic Trinocular head, inclination adjustable from 10-50 degrees .I.P. adjustment 53mm to 75mm, graduated diopter on left eyetube ( 23.2mm I.D. eyetube). Ergonomicaly inclined at 10-50 degrees, enables to adjust wider range of eyepoint height, which enables different torso sizes to observe in a relax ergonomic posture. Scale diopter adjustment for easy diopter adjustment. This adjustment adapts to the user to make quick and accurate adjustments to match the interpupillary distance and diopter adjustment. (Included in MT4200EL)

MT4300EL-FRONT MT4300EL-SIDE

MA958: Photo / video attachment with sliding 80/20 beam-splitter. For use with video or digital cameras when MA957/05 ergonomic head is used

MICROSCOPE EYEPIECES - COMPENSATING EYEPIECE, 23.2MM WIDTH
   • MA407 (x 2): KHW10X compensating eyepiece, Field No. 20, Tube O.D. 23.2MM (each), Anti-fungus coating to prevent fungi and mold when used in humid, hot environments. Improving greater durability and maximum optical quality

MT4300EL_MA958

MICROSCOPE OBJECTIVES - INFINITY CORRECTED OPTICAL SYSTEM,F=200MM
   • MA831: U. Plan Objective 4X, N.A 0.10, W.D. 25.8mm, F.N. 24
   • MA832: U. Plan Objective 10X, N.A. 0.25, W.D. 10.7mm, F.N. 24
   • MA834: U. Plan Objective 40X, N.A. 0.65, W.D. 0.5mm, F.N. 24
   • MA837: U. Plan Objective 100X oil, N.A. 1.25, W.D. 0.23mm, F.N. 24

objectives1 objectives2

MICROSCOPE CONDENSER - CENTRABLE ABBE CONDENSER WITH A HIGH N.A. AND BUILT IN IRIS DIAPHRAGM
   • MA910: Centrable Abbe Condenser, N.A. 1.25 with iris diaphragm and dove-tail mount

MT4300EL_Condenser

 MICROSCOPE STAGE - BUILT IN CERAMIC STAGE FOR SMOOTH SLIDE REPLACEMENT 

   • MA917R:Ceramic coated flat-top stage, 170mm x 140mm, 80mm x 52mm ( Factory Installed)

MT4300EH_STAGE

MICROSCOPE FOCUSING ADJUSTMENT-WITH TENSION ADJUSTMENT CONTROL
   • Focusing Adjustment: Japanese Precision coaxial coarse and fine focusing controls with graduation reading 2 microns per division. Range of travel is 23mm. Incorporates tension adjustment and safety Auto-focus stage stop lever. (Factory Installed)

MT4300D_Focus_knob

ATTACHABLE FINGER ASSEMBLY FOR STABLE SLIDE PLACEMENT
   • MA598: Attachable finger assembly for MA917R and MA917L

fingerassembly

BUILT IN HIGH EFFICIENCY TRANSMITTED LED 0.5W ILLUMINATION AND FUSE
   • LED/SP-1: 3W LED, 5500K color temperature
   • MA929: Spare fuse 0.5A for MT4000 LED Illuminator

AC ELECTRIC CORD IS SUPPLIED WITH THE PROPER VOLTAGE SELECTED

   • MA809/10: Removable AC Electric cord with plug for 115V models (Included in all 115V models) or
   • MA809/20: Removable AC Electric cord with plug for 220V models (Included in all 220V models)

DUST COVER FOR DUST PROTECTION
   • MA701: Dust Cover for MT4000  (PLEASE MAKE SURE THAT THE UNIT IS TURNED COMPLETELY OFF BEFORE PUTTING ON THE DUST COVER)

FACTORY MANUAL SUPPLIED
   • Manual: MT4000 Meiji Techno Instruction Manual
   • Warranty: Limited Lifetime Warranty Card

Product Information:
   • Manufactured: 100% MADE IN JAPAN
   • Warranty: LIMITED LIFETIME WARRANTY
   • Customer Support: 1-(800) 832-0060 (U.S.A Based)

Package Information:
   • Weight: 29 lbs (8.0kg)
   • Box Size: 16 x 14 x 21 inches
   • Footprint: 263mm (D) x 176mm (W)
   • Binocular head type: 390 mm(D) x 410mm (H) x 210mm(W) (8.0kg)( 29.0 lbs)
   • Trinocular head type: 390 mm(D) x 465mm(H) x 210mm(W) (8.7Kg)( 30.0 lbs)
   • Binocular Ergonomic head type: 390 mm(D) x 483mm (H) x 210mm(W) (8.4kg)(31 lbs)
   • Trinocular Ergonomic head type: 390 mm(D) x 533mm(H) x 210mm(W) (8.9Kg)(33 lbs)

HD1500TM Includes:
   • HD1500TM Camera
   • HDMI Cable
   • USB Cable
   • 12V AC/DC Power adapter
   • SD Card
   • Mouse
   • Application Software ISCapture
   • Packing Box
Package Information:
   • 5lbs
   • 12 x 10 x 4 inches

NEW: BUILT-IN MOUSE CONTROL CAMERA
The significant innovation of the HD15000T is making the software implant inside the camera. This forward thinking feature frees users from cumbersone computers and annoying buttons. You can control the camera by only a mouse directly.

01

Videos of the camera in action with our microscopes:
Brief overview with the compare feature
With Darkfield microscopy.

 

PERFECT COLOR REPRODUCTION
Meiji Techno's HD technology offers true-to-life reproduction oh image color. What you see on the monitor is what you get from the microscope eyepiece. No compressed date transmission, resulting in scientific-grade images.

02

1080P 60FPS FULL FRAME RATES
With 60fps at 1080p, the HD1500T presents a perfect combination of outstanding resolution and frame rate. This allows the user to fluently manipulate the live images without any lags.

03

HDMI+USB 2.0+SD OUTPUT
Multiple output options are available for this powerful HDMI camera. HDMI 1080P, USB 2.0, or SD memory card can be used individually or all three SIMULTANEOUSLY.

03

DUAL FPGA PROCESSORS
With an innovative Dual FPGA processor architecture design, FPGA1 for image quality processing and FPGA2 for image output control, you get a high-speed preview without sacrificing image quality. It is the most powerful camera you deserve to have.

05

SMART PRESENTATION
Camera parameters such as exposure time, white balance, and gain are designed by default to operate automatically. Automatic optimum configuration is expected to be done in 0.015 seconds, and you'll find that the camera is easily managed from the start.

06

ADVANCED PARAMETER SETTING
For users with specific requirements, the camera is designed with parameter setting buttons that enable manual adjustment of white balance, gain, saturation, Gamma and screen freeze.

07

PC TO TV
Images are displayable on PCs and HDMI-installed TVs. All parameters can be controlled by the computer to adjust them to actual situations. This is advantageous in teaching and meeting applications.

08

On-board Video Saving
The SD card can save not only still images, but also dynamic images in 720P color definition, such that motion trails are recorded in fast speed and intact form.

09

LOW LIGHT SENSITIVITY
Thanks to its highly sensitive sensor, the HD1500T is capable of capturing low-light images rapidly. In darkfield imaging and even fluorescence, it will automatically increase the sensitivity, presenting low light images with clarity in high-speed preview mode.

10

Model
Type
Version
Mega Pixels
Resolution
Frame Rate (FPS)
Sensor
C" Mount

HD1500T

HDMI/USB 2.0 Color 2-6MP 3264 x 1840 Static
1920 x 1080 Dynamic
60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500TM
with 11.8" HDMI montior

HDMI/USB 2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET

HDMI/USB 2.0 Color 2-6MP 3264 x 1840 Static
1920 x 1080 Dynamic
60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET-M
with 11.8" HDMI montior

HDMI/USB 2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET-AF
(Autofocus/Continuous 1-shot)

HDMI/USB2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET-M-AF
(Autofocus/Continuous 1-shot/with 11.8" monitor)

HDMI/USB2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1000-LITE

HDMI/USB 2.0 Color 5MP

2592 x 1944

15fps by HDMI
15fps by USB 2.0

1/2.5" CMOS

0.3X

HD1000-LITE-M
with 11.8" HDMI montior

HDMI/USB 2.0 Color 5MP

2592 x 1944

15fps by HDMI
15fps by USB 2.0

1/2.5" CMOS

0.3X

HD1600T

USB 3.0 Color 16MP 4608 x 3456

25fps by USB 3.0

1/2.33" CMOS

0.3X

SS500-MC

Wifi Color 5MP 2912 x 1640 60fps by Wifi 1/2.3" CMOS 0.3X

WF300
Eyepiece Camera

Wifi Color 8MP 3200 x 2400 60fps by USB 2.0
30fps by Wifi
1/2.8" CMOS 20-43mm
Eyepiece Mount

WF200

Wifi Color 5MP 2592 x 1944 40fps by USB 2.0
15fps by Wifi
1/2.8" CMOS 0.3X

WF100
Document Scanner

Wifi Color 5MP 2592 x 1944 30fps by Wifi - -

X-1000U

USB 2.0 Color 5MP 2592 x 1911 10fps by USB 2.0 1/2.8" CMOS 0.3X

MIS-PL-DV24

USB 2.0 Color 2MP 1600 x 1200 30fps by USB 2.0 1/2" CMOS 0.5X

DK-LITE-B

USB 2.0 Color 1.5MP 1440 x 1080 10fps by USB 2.0 1/2.5" CMOS 0.5X

DK1000CB

USB 2.0 Color 2MP 1600 x 1200 15fps by USB 2.0 1/2" CMOS 0.5X

DK1000M

USB 2.0 Monochrome 1.3MP 1280 x 1024 30fps by USB 2.0 1/2" CMOS 0.5X

DK3000C

USB 2.0 Color 3.1MP 2048 x 1536 12fps by USB 2.0 1/2" CMOS 0.5X

DK5000C

USB 2.0 Color 5MP 2592 x 1944 5fps by USB 2.0 1/2.5" CMOS 0.7X

HD2000C

USB 2.0 Color 2MP 1920 x 1080 60fps by USB 2.0 1/3" CMOS 0.3X

ST1000C

USB 3.0 Color 5MP 2592 x 1944 60fps by USB 3.0 1/2.5" CMOS 0.5X

 

Frequently Asked Questions

Q: Start the software and get the camera recognized, but the preview is all black.
A: Check whether the anti-dust cap on the C-mount is removed. If already removed and attach the camera to the microscop, check whether the lighting path toggle switch to the camera. Then try to extend the exposure time and gain to get brighter images.

Q: The imaging scene from the eyepiece is in focus but the live images from the camera are still out of focus.
A: This is because the camera and the eyepiece are in different focal planes. Can consider to use adjustable adapter to connect camera to the microscope trinocular, and the adjust the adapter to make the live image in focus.

Q: There are some shadows on the image and the shadows always stay in the same position even when the sample is moved.
A: Possible reasons:
1. The anti-dust film on the camera C-mount is not removed. Remove the anti-dust film
2. Check to see if there is any dirt on the objective. Clean the objective.
3. Some dust on the surface of the camera IR filter. Clean the camera optical port.

Q: Camera frame rate is extremely slow.
A: Possible reasons:
1. Preview resolution is too high. Try lowering the resolution and check the change of the frame rate.
2. Exposure time is too long. If need exposure time longer than 200ms, try to use higher gain to get brighter images.
3. Computer issue. Computer is very old or the motherboard chipset is Intel 8 Series/C220 series.

Q: Start the software and get the error message: can not recognize the camera or No camera.
A: Possible reasons:
1. The camera USB cable is not well connected. Reconnect the camera again.
2. Check whether the camera is connect to the USB port on the front of the mainframe. If so, then connect it to the USB port on the back of the mainframe. The USB ports on the front of the mainframe are the extended ports from the motherboard which can not provide stable voltage and current for cameras.
3. The camera itself needs extra power supply but does not switch on the power. TrueChrome is required to switch on power, attach to the PC and then restart the software. TCC-6.1ICE is required to plug in power to be recognized by PC.
4. The camera driver is not installed or failed to install. Go to the "Device Manager" > "Imaging Devices" and check whether the camera is listed WITH YELLOW FLAG. Then re-install the driver again. If still fail to install to driver, please contact camera technical support for help.

Q: Image Field of View (FOV) is much smaller than the scene can be seen from the eyepieces.
A: Possible reasons:
The camera sensor size is not 1 inch. It needs reduce lens to get bigger FOV.
Low resolution is used to preview. Set full resolutionion.
The reduce lens does not match the camera sensor size.

Q: When push “Capture” button, sometimes the saved images are quite blurry.
A: It could be because some slight vibration happens on the camera during capturing the images.

Q: Security shield on ISCapture shortcut.
A: Some anti-virus or firewall softwaree installed in the PCs will identify the DLL files from ISCapture as virus and automatically isolate or delete the ISCapture software files. If have the warning message to delete or isolate the DLL files during the ISCapture installation, please ignore the warning message or set the ISCapture as trusted software. Otherwise, the ISCapture can not be used normally.

Q: Newer version software con not recognize the old cameras.
A: Currently, all the newer version software ISCapture is compatible with the previous version cameras EXCEPT TCA Series.

Q: After doing the measurement on the live images, the captured image is without any measurement data.
A: To save the live measurement on captured images, check the “Combined Measurements” checkbox in the File Save tab and then capture images. While doing the still image measurements, only click the Save or Save As on the right hand side shortcut to save the data on the images.

Q: The live images and the captures images color is quite different from the one we can see from the eyepieces.
A: Because of the different lighting source, White Balance is needed to correct the image color.

Q: How to do quick White Balance?
A: White Balance while attached to camera to stereo microscope: Use a white paper to replace the sample. Click on “White Balance” to correct the image color > Remove the white paper and put back the sample.
White Balance while attach the camera to the biological microscope: Move the sample slide to the blank area. Click on “White Balance” and move back the sample.

Q: After install ISCapture and firstly start the software, but get the error “The program can’t start because MSVCP100.dll is missing from your computer. Try reinstalling the program to fix this problem.”


A; This is because the operating system lack of some Visual C++ 32bit library files which the ISCapture needs to call them. Without these files, the software can not be started normally. Install the patch VCredist_x86.exe (can be found in the CD that comes with the camera or go to http://www.microsoft.com/en-us/download/details.aspx?id=5555

Q: Start the ISCapture but get the error “Unable to execute file C:\Program Files\ISCapture\ISCapture.exe CreateProcess failed; code 740.

 


A: Completely remove the ISC Capture, reboot the PC and then right click on ISCapture installer (ISCapture Setup.exe) and select “Run as Administrator” to install the ISCapture. When you first start the software right click on the ISC icon and select “Run as Administrator” to start it.

Q:When start ISCapture, get error message “Cannot find the USB Key!”

A: The software is encrypted. Specific USB key is needed to attach to the computer port first.

Q:After capturing several images, it takes more and more time to save a frame image. Sometimes it is even up to more than 30 seconds, and then finally the software hang or crash.
A: If the image save directory is the network driver, during uploading the files to network driver, it will significantly increase the COP usage. When the CUP usage is up to 100%, the software will hang or crash. Recommend to change the file save directory to the computer hard disk.

Q: Whether can share the calibration files on different PCs?
A: If using the ISCapture earlier version than V4.0: Go to the folder “Application Data/ISCapture” in system disk, find the file “calibrationTable.ini” and copy it to another PC under the same directory. (The “Application Data” folder is a hidden folder, you might need to make the system invisible visible first.)
If it is ISCapture V4.0 or later, go to the Parameter tab and click “Backup” to backup the parameter settings and copy them to another PC to restore them.

Q:After install the ISCapture and every time I run the software i get the error:

A: This is because some program in the user’s PC is using the library file ‘libiomp5md.dll’which will conflict with the ISCapture. So far as we know, the software GoPro Studio will conflict with ISCapture. To solve this issue, please try to remove the libiomp5md.dll from the C:\Windows\System32 folder while using the ISCapture.

Q: Shortcut keys for ISCapture to capture still images and videos:
A: With ISCapture V3.6.6 or later, running the ISCapture first, Press F9 key on the keyboard to capture images. Press F10 to start the video recording. If in manual recording mode, press F11 to stop the recording.

Q: On preview images, lots of horizontal lines appear.


A: This is because of the lighting frequency. Extend exposure time or turn off the filament lamp or fluorescent lamp in the environment to solve this issue.

Q:Recording issue when connected to the HD1500T/HD1000 Series to the monitor and recorded video directly to the SD card? If so, do you know what the capacity of the SD card the user used during recording the videos?
A:When recording videos to the SD card, the camera only supports the SD card with format SDHC. It can not work with the SD card format SDXC. And max. capacity of the SDHC format SD card is 32GB which means the SD card with capacity >= 64GB, is format SDXC.
If already use SDHC format SD card, please help to confirm the information below:
1). Whether the customer used the SD card came with the HD1500T/HD1000 camera?
2). If not, what exactly the model of the SD card the customer used? Maybe some picture of the SD card.

If got the issue while connect the camera to the computer, I need to confirm below information:
1). The software always stop recording AUTOMATICALLY after 5-10 minutes?
2). Whether the software or the computer freeze if MANUALLY stop the recording?

Product Information: 
   • Manufactured: 100% MADE IN JAPAN / 100% MADE IN UK (CoolLED)
   • Warranty: LIMITED LIFETIME WARRANTY 
   • Customer Support: 1-(800) 832-0060 (U.S.A Based)

MT4300EL Package Information: 
   • Weight: 29 lbs (8.0kg)
   • Box Size: 16 x 14 x 21 inches 
   • Footprint: 263mm (D) x 176mm (W)
   • Trinocular Ergonomic head type: 390 mm(D) x 533mm(H) x 210mm(W) (8.9Kg)(33 lbs)

HD1500TM Package Information:
   • 5lbs
   • 12 x 10 x 4 inches

Details

The MT4000 Microscopes features include:

  • Compact Space Saving Footprint design with ergonomics in mind
  • Infinity Corrected Optical System (ICOS™) with all newly designed Planachromatic optics
  • Comfortable Siedentopf-type Binocular and Trinocular Viewing heads
  • Optional Ergonomic tilting binocular head- Adjustable vertically from 10°to 50° degrees
  • Ceramic Coated Stage with Ergonomically Placed Low Position Drop down Control
  • Parfocalled Microscope Objectives
  • Tension adjustment control with Coaxial knobs
  • Low Positioned Ergonomic Coaxial Focus Control
  • Low Positioned Ergonomic Coaxial Focus Control
  • Smooth Operating Ergonomic Quintuple Nosepiece
  • Brightfield and Phase Contrast Observation modes available
  • Super Bright LED Koehler illumination, lambertian design
  • Integrated 30-Watt Halogen Transmitted illumination System on selected Brightfield and Phase Contrast Models
  • Abbe and Zernike Phase Contrast Condensers available
  • Integrated Automatic Voltage Sensing Power Supply with localized power cord
  • Rear Cord Wrap for easy storage
  • Wide Range of Filters and Accessories

Brightfield:
The simplest of all the optical microscopy illumination techniques. Sample illumination is transmitted (i.e., illuminated from below and observed from above) white light and contrast in the sample is caused by absorbance of some of the transmitted light in dense areas of the sample. Brightfield microscopy is the simplest of a range of techniques used for illumination of samples in light microscopes and its simplicity makes it a popular technique. The typical appearance of a brightfield microscopy image is a dark sample on a bright background.

The MT4000 Series is a newly designed upright biological compound microscope system. Ergonomically designed, precisely manufactured and simple to use stage and coarse and fine controls. To meet the demands of researchers and clinical laboratory specialists. The MT4000 Series was to develop to provide functionality and operational ease. Viewing high quality images, sample changing and photomicroscopy are all conducted with ergonomics in mind. High luminescent LED illumination reduces need for frequent bulb replacement but still provide rugged durability and long life span.

VIEWING HEADS
Model MA815/05 is the Siedentopf-type binocular head and Model MA816/05 is the trinocular head for camera integration. Each head has the eyetubes inclined at 30 ° with the left eyetube having graduated diopter settings. The interpupillary distance is adjustable between 53mm - 75mm. An 80/20 beamsplitter for the trinocular tube can be engaged for photo work.The optional MA957/05, Ergonomic Binocular Viewing Head, has the inclination adjustable from 10 to 50 degrees to fit users of different heights. The Ergonomic Trinocular model comes with the MA958, photo/video attachment with sliding 80/20 beam-splitter (Included in MT4300ED).

EYEPIECES
10X Widefield High Eyepoint eyepieces F.N.20 are standard, and 15X and 20X eyepieces are available as an option. A Widefield High Eyepoint 10X focusable eyepiece that accepts 21mm reticules is also available.

OBJECTIVE CHANGER
Quintuple nosepiece provides effortless objective changes with smooth-operating, ball bearing mounted.

OBJECTIVES
Meiji Techno America offers an assortment of Planachromat Infinity Corrected (ICOS) objectives for Brightfield, Darkfield and Phase Contrast observation modes.

STAGE
Ceramic coated standard right-handed or optional left-handed controls, flat top stage 171mm x 115mm and travels 78mm(X) x 52mm(Y). Ergonomically positioned coaxial drop down controls. Available with motorized focus and stage controls.

CONDENSER
New design centerable Abbe 1.25 N.A. Condenser with built-in iris diaphragm in dovetail mount.

ILLUMINATION
Powerful white LED illumination provides enhanced image quality and brightness for the observation of specimens and photomicroscopy.

PHOTOMICROGRAPHY
Meiji Techno offers a broad range of digital video cameras which offers excellent sensitivity, high resolution and a wide dynamic range for the most demanding brightfield and darkfield microscopy applications including clinical pathology and cytology, life sciences and geology. Some models has included software, that can preview and capture still shots and live videos to a PC or Mac with USB port or HDMI connectivity.

Details

Biological TerminologyModel
Model
Head
Illumination
Eyepieces
Objectives
Stage
Condenser

MT4200L

Binocular
LED Illumination
 
KHW10x FN20
U. Plan 4x, 10x, 40x, 100x oil
Fixed flat-top left or right-handed controls
Abbe NA 1.25 with iris in dovetail mount

MT4200EL

Ergonomic Binocular

MT4300L

Trinocular

MT4300EL

Ergonomic Trinocular

MT4200H

Binocular
Koehler 30W halogen

MT4200EH

Ergonomic Binocular

MT4300H

Trinocular

MT4300EL

Ergonomic Trinocular

Components & Accessories

Included:
   • MT4300EL: Ergonomic Trinocular Brightfield Compound microscope with Bright LED Koehler illumination with quintuple nosepiece and auto voltage sensing power supply
   • MA957/05: Ergonomic binocular head, inclination adjustable from 10-50 degrees 
   • MA958: Photo/video attachment with sliding 80/20 beam-splitter. For use with video or digital cameras when ma957/05 ergonomic head is used
   • MA407 (x 2): KHW10X compensating eyepiece, Field No. 20, Tube O.D. 23.2MM (each)
   • MA831: U. Plan Objective 4X, N.A 0.10, W.D. 25.8mm, F.N. 24
   • MA832: U. Plan Objective 10X, N.A. 0.25, W.D. 10.7mm, F.N. 24
   • MA834: U. Plan Objective 40X, N.A. 0.65, W.D. 0.5mm, F.N. 24
   • MA837: U. Plan Objective 100X oil, N.A. 1.25, W.D. 0.23mm, F.N. 24
   • MA910: Abbe condenser, N.A. 1.25 with iris diaphragm and dove-tail mount
   • MA917R: Ceramic coated flat-top stage, 170mm x 140mm, 80mm x 52mm
   • MA598: Attachable finger assembly for MA917R and MA917L
   • LED/SP-1: 3W LED, 5500K color temperature
   • MA929: Spare fuse 0.5A for MT4000 LED Illuminator
   • MA809/10: Removable AC Electric cord with plug for 115V models
   • MA701: Dust Cover for MT4000
   • MA151/35/03: C” mount adapter with 0.3X lens
   • HD1500TM: The HD1500TM’s display features full HD (1080x1920) resolution and provides high fidelity images from the HD1500TM with a refresh rate of 60 frames per second. Included with the display is a mounting kit that allows the display to be mounted directly on the HD1500TM. 

OPTIONAL COMPONENTS & ACCESSORIES BELOW

Viewing Heads:

   • MA816/05: Trinocular head - Siedentopf type, I.P. adjustment 53mm to 75mm, graduated diopter on left eyetube (23.2mm I.D. eyetube). Inclined at 30 degrees (Included in Model MT4300L, MT4300H, MT4310L and Model MT4310H) Inverted image
   • MA957/05: Ergonomic binocular head, inclination adjustable from 10-50 degrees (23.2mm I.D. eyetube) Erect image. (Included in all Ergonomic Bino. & Trino. models)

Photo/Video Attachment:
   • MA958: Photo / video attachment with sliding 80/20 beam-splitter. For use with video or digital cameras when MA957/05 ergonomic head is used (Included in all Ergonomic Trinocular models)

Eyepieces:
   • MA407/05: KHW10X-F Compensation Focusing eyepiece, Field No. 20, Tube O.D. 23.2mm (each)
   • MA200: Eyeshield for MA407 KHW10X eyepiece (each)
   • MA408:HWF15X Widefield eyepiece, Field No. 12.2, Tube O.D. 23.2mm (each) (no reticle mount)
   • MA409:HWF20X Widefield eyepiece, Field No. 9, Tube O.D. 23.2mm (each) (no reticle mount)
   • MA406:HWF10X Widefield high-eyepoint eyepiece, Field No. 18, Tube O.D. 23.2mm (each) (19mm reticle mount)
   • MA413:HWF10X Focusing eyepiece with reticle mount, Field No. 18, Tube O.D. 23.2mm (each) (19mm reticle mount)

U. Plan Objectives:
   • MA833: U. Plan Objective 20X, N.A. 0.40, W.D. 7.29mm, F.N. 24
   • MA836: U. Plan Objective 50X oil with iris, N.A. 0.87, W.D. 0.28mm, F.N. 24
   • MA837: U. Plan Objective 100X oil, N.A. 1.25, W.D. 0.23mm, F.N. 24
   • MA838: U. Plan Objective 100X oil with iris, N.A. 1.25, W.D. 0.23mm, F.N. 24

U. Plan Phase Objectives:
   • MA839: U. Plan Phase Objective 10X, N.A. 0.25, W.D. 10.7mm, F.N. 24 (Included in PH model)
   • MA840: U. Plan Phase Objective 20X, N.A. 0.40, W.D. 7.29mm, F.N. 24
   • MA841: U. Plan Phase Objective 40X, N.A. 0.65, W.D. 0.5mm, F.N. 24 (Included in PH Model)
   • MA842: U. Plan Phase Objective 100X oil, N.A. 1.25, W.D. 0.23mm, F.N. 24

Centering Telescope:
   • MA458: Centering Telescope, 23.2mm OD (Included in Models MT4210L, MT4310L, MT4210H and MT4310H)

Polarizer:
   • MA915: Polarizer set for MT4000 Series microscopes
   • MA915/PT#2: Unmounted 43mm polarizing filter for use with MA1043 Intermediate tube
   • MA1043: Intermediate tube with built in analyzer and compensator slot for MT4000 & MT5000 Series (requires a MA915/PT#2 43mm polarizing filter)

Condensers:
   • MA910/10: Abbe condenser, N.A. 1.25, with centerable Phase annuli in slider for use with 20X and 40X phase objectives, with iris diaphragm and dovetail mount
   • MA910/15: Abbe condenser, N.A. 1.25 with darkfield stop in slider for use with 20X and 40X brightfield objectives, with iris diaphragm and dovetail mount
   • MA911: Achromatic condenser, N.A. 1.25 with iris diaphragm and dovetail mount
   • MA913: Zernike Phase condenser with centerable phase annuli for 10X, 20X, 40X, 100X with brightfield position, dark-field stop for 40X objective, (black-out position- for epi-fluorescence on MT6000 Series only) with iris and dove tail mount (Included in Models MT4210L, MT4310L, MT4210H & MT4310H)
   • MA976: Abbe condenser, N.A. 0.90 with swing out top lens, iris diaphragm and dovetail mount For use with low power scanning objectives

Filters:
   • MA858/05: ND 25 Neutral density filter, 44.0mm diameter, unmounted
   • MA857/05: Green filter, clear, 44.0mm diameter, unmounted (Optional)
   • MA861/05: Green Interference filter, 44.0mm diameter, unmounted 546nm (Included in all Phase Contrast Models)

Stages:
   • MA917L: Ceramic coated flat-top stage, 170mm x 140mm, 80mm x 52mm X-Y movement, with left hand drop-down coaxial controls
   • MA598: Attachable finger assembly for MA917R and MA917L (Included with MA917R & MA917L)
   • MA676: Attachable clinical finger assembly for MA917R and MA917L

Eyepiece Micrometers (21mm diameter for use with MA407 eyepiece)
   • MA284: Cross-line reticle, 21mm diameter
   • MA255: 10mm line divided into 100 units, 21mm diameter
   • MA256: 5mm line divided into 100 units, 21mm diameter
   • MA283/05: 10mm square divided into 100 parts, each square 1.0mm, 21mm diameter
   • MA540: Cross-line reticle with 0.1mm graduations, 21mm diameter

Stage Micrometers
   • MA285: 1mm divided into 100 units, 0.01mm
   • MA286: 0.04” divided into 40 units, 0.001”

Replacement Bulbs and Fuse
   • MA326 Spare Bulb, 6V, 30W halogen lamp ( For use with MT4000 Halogen models)
   • MA327: Spare 3A Fuse for MT4000 Halogen Illuminator
   • LED/SP-1: 3W LED, 5500K color temperature
   • MA929: Spare Fuse 0.5A for MT4000 LED Illuminator

Miscellaneous
   • MA977: Eye level riser for MT Series stands
   • MA701:Dust Cover for MT Series stands(vinyl)


Double click to read at full screen
Download Brochure (PDF)



Double click to read at full screen
Download Manual (PDF)


Download Camera Driver (ZIP)
Download TCapture Software (ZIP)


Download MAC ISListen Capture Software (2018)
Download ISListen MAC Installation Guide (PDF)


 


Double click to read at full screen
Download Manual (PDF)


 


Double click to read at full screen
Download Software Manual (PDF)


 


Double click to read at full screen
Download Menu Quick Guide (PDF)


 


Double click to read at full screen
Download Calibrate Guide (PDF)


 


Double click to read at full screen
Download TCapture Software Manual (PDF)