BAS-20SP 20MM Straight Drop Down Post for FA-3 or BAS-2 Stands

The BAS-20SP is a 20mm staright drop down post that is 4″ in length. The BAS-20SP is compatible with FA-3 and BAS-2 stands which are used in CZ, EM, Short Unimac series.

NOTE: Additional items are needed to create a full microscope system. The following components are normally ordered: 
• Stereo Microscope Body (Zoom, Turret or Fixed) 
• Eyepieces (Requires 2 of identical magnification) 
• Stand (Pole stands, rigid arm stands, boom stands, heavy duty boom stands, wide surface stands or articulated arm stands) 
• Illumination Source (Fiber optic halogen, fiber optic LED, fluorescent ring or LED illumination) 
• Auxiliary Lens (Optional)

Locate a DealerGet a Quote

Description

BAS-2 Features

• BAS-2 is a heavy duty dual ball bearing arm industrial-type boom stand comes with a 32mm diameter drop down mounting post to perfectly complement our EMZ (Zoom), EMT (Turret), EMF (Fixed) Series Stereo Microscope with the proper focus block
• BAS-2 uses linear ball bearings to support the horizontal arm, allowing it to glide over the work surface with none of the binding inherent in other boom stands
• 635mm (25”) vertical pole (Included)
• 457.2mm (18”) horizontal pole (Included)
• Minimal space requirement and greatest possible amount stability for EM Series stereo system up to 30lbs
• No loss of stability even at its furthest travel
• The BAS-2 can swing out of the way easily, clearing the workstation for other tasks
• Vertical column is used to compensate for taller specimen heights to accommodate the working distances of different microscope bodies
• Anti-rotation is stabilized by a locking pin on the vertical post
• Safety Collar for vertical and horizontal stability
• BAS-2 is equipped by a 80lb base
• Ergonomic flexibility, chemical resistant paint finish and corrosion resistant stainless steel columns make this boom stand an excellent choice in labs and production facilities
• High density rubber feet for vibration stability
• 100% MADE IN U.S.A

FA-3 Features

• Articulating Stand with table Clamp for Examination of Large Working Area
• 37″, 939mm Reaching-out Length
• 16″, 406mm High Stainless Steel Pillar
• 16 mm diameter bonder arm mounting pin (5/8”)
• Locking handles keep the Articulated stand in position
• Triple –Joint Articulating Design for Flexibility
• Accepts FS tilting coarse focusing holder with 84.2 mm round diameter opening(Optional)
• Accepts FSC tilting coarse and fine focusing holder with 84.2 mm round diameter opening (Optional)
• Accepts OS-SP20MM – 20mm drop down post for use with focus blocks with a 20mm mounting hole (optional)

Additional information

Weight 1.0000 kg
Components & Accessories

BAS Stand Series and Accessories• BAS-1: Ball bearing stand with dual horizontal arms, 13" x 13" x 1.5" base,  25" vertical post, safety clamp, 32mm straight mounting post • BAS-32SP: Replacement 32mm straight mounting post for BAS-1 (For use with RZ Series) • BAS-38SP: Replacement 38mm (1.5") diameter, straight drop post with 5/8" mounting pin • BAS-32TP: Replacement tilting 32mm mounting post with 5/8" mounting pin • BAS-2: Ball bearing stand with dual horizontal arms, adjustable from 5.5" to 18", 13" x 13" x 1.5" base, 25" vertical post, safety clamp and 20mm straight mounting post for MS-51/05 or MS-53/05 holder (Note: Socket Head cap screw for base: 1/2" x 2" 13TP)• BAS-3: Ball bearing stand with dual horizontal arms, 13" x 13" x 1.5" base, 25" vertical post, safety clamp for MS-52/05 or MS-54/05 holder• BAS-20SP: 20mm straight drop down post for FA-3 or BAS-2 stand 4" in length 

Downloads

Double click to read at full screenDownload Brochure (PDF)
 

Double click to read at full screenDownload Manual (PDF)

Lighting Options

Replacement Bulbs Listed by Part Number
NOTE: The size of these images will vary and some images have been re-sized to fit this page. Do not rely on the size of these images to determine which bulb you need. NOTE: Incident light shines down from above; transmitted light shines up through the specimen from below.
 

MA111
MA260/05
MA261/SL-10
MA263/05 MA263/10
MA264/05
MA275/05

 

Part Number
Description
Application

MA111
12V 10W
Incident light:ST-3, SKT-1B, SKT-2B, SKT-3B, GS2000 Incident & transmitted light: SKT-BT, SKT-2BT, SKT-3BT Transmitted light: STC-3

MA260/05
6V 20W Halogen
For MA260, MA264H, and MA264EX illuminators

MA261/SL-10
115V 20W

For "B" Stand and MA261/35 (TM200 Series illuminator)

MA263/05

115V 30W

For MA263 illuminators

MA263/10
220/240V 30W
For MA263 illuminators

MA264/05
6.5V 2.75A
For MA264 illuminators

MA275/05
12V 50W
For ML5000 Series 50W models; ML7500, ML8500 All MT7500, MT8500 series

MA305/05 
MA309/05
MA326
MA350/10 MA350/20
MA361/10 MA362/10

 

Part Number
Description
Application

MA305/05
8W Ring Fluorescent
For MA305/100, MA305/200 ring fluorescent illuminators 

MA309/05
4W Tube Fluorescent
For MA309 fluorescent box illuminators for GEM stand 

MA326
6V 30W Halogen (G4 base type) 

For ML2000 and ML5000 Series 30W models; all VT Series Models, IM7100, IM7200, ML2000, ML7000, ML8000, ML9000, TC5100, TC5200, TC5300, TC5400, TC5500, TC5600 All MT Series 30W models; all RZT & RZDT Stands

MA350/10

115V 30W

For GEM stand transmitted light

MA350/20
220/240V 30W
For GEM stand transmitted light

MA361/10*
110V 20W
Half-silvered bulb for TM400 Series 20W models (DISCONTINUED)

MA361/20*
220/240V 20W
Half-silvered bulb for TM400 Series 20W models

MA362/10*
115V 30W
Half-silvered bulb for TM400 Series 30W models (DISCONTINUED)

MA362/20*
220/240V 30W
Half-silvered bulb for TM400 Series 30W models(DISCONTINUED)

MA560
MA561
MA570
FL180/70 FL150/70
MA357
MA358
MA590

 

Part Number
Description
Application

MA560
6V 1.2A Tungsten 
Incident light: AB, ABZ, PB Stands All BM/BMK Series models 

MA561
6V 1.2A Tungsten 

Transmitted light: AB, ABZ, PB Stands
Note: MA560 and MA561 may appear to be identical, but they are not interchangeable.

MA570
6V 10W Halogen 

Incident & transmitted light: ABE, ABH, ABZH, PBH Stands

FL150/70

21V 150W Halogen 

For Fiber Optic Light sources: All FT190 and FL150 Series

FL180/70
21V 150W Halogen 
For FL180, FL181 & FL182 fiber optic illuminators

MA357
8V 12W Tungsten 
Frosted – Fits Meiji Techno MT5500 Series Microscopes

MA358
8V 12W Tungsten 
Clear – Fits Meiji Techno MT5500 Series Microscopes

MA590
110V 15W Tungsten
Frosted – Fits Meiji Techno PBM Series Stands

DC Arc Lamps

Part Number
Description
Application

BA005
HBO 100W Mercury DC Arc Lamp
TC5000 Series & MT6000 Series Equipped with Epi-Fluorescence Lamphouses

BA013
XBO 75W Xenon DC Arc Lamp  

BA014
XBO 100W Xenon DC Arc Lamp   

BA005 Information:
Brand: Ushio Technology: Short-Arc Mercury Useful Life Hours: 200 Lumen Output: 2200 Actual Wattage: 100 Voltage: 20 Base Type: SFa7.5+SFa9 Length (Inch): 3.54 Diameter (Inch): .394Manufacturers Notes: The HBO 100W BA005 is a Mercury Arc 20V 100 W Lamp with a SFa7.5-2 base
This product is also a direct replacement for the following items:

100W OSRAM HBO MICROSCOPE
4050300507095
ALB UPC LER38445
ALB UPC: LER38445
ALB UPC:LER38445
AMERICAN OPTICAL 2087 BULB
DENTSPLY ULTRA CURE 100
EFOS ULTRA CURE 100
EFOS ULTRA CURE 100 BULB
HANOVIA HGH100W2 BULB
HBO 100W/2
HBO 100W/2 BULBS
HBO 100W/2 LIGHT BULB
HBO 100W/2 MERCURY LAMP
HBO 100W/2 OSRAM BULB
HBO 100W/2 OSRAM BULBS
HBO.100W.2
HBO100W/2
HBO100W/2 BULB
HBO100W/2 LAMP
HBO100W/L2
HBO100W2
JENA HBO 101/2 BULB
LD CAULK ULTRA CURE 100
LEICA 2087
LEICA 2087 BULB LAMP
LEICA 2087-001 BULB
LEICA 3040-0380 BULB
LEICA 500-138 BULB
LEICA 500138
LEICA DMRBE BULB
LEITZ 2087 BULB
LEITZ 2087-001 BULB
LEITZ 3040-0380 BULB
LEITZ 500-138
LEITZ 500-138 BULB LAMP
LEITZ DMRBE BULB LAMP
LER38445
LITE SOURCE LS-97 BULB
M5000-133
MICROSTAR IV MICROSCOPE
MICROVISION 804-137-001
MITEY LITE AMERICAN OPT
NARVA HBO 101/2 BULB
NIKON 1996G7 BULB
NIKON 235915 BULB
NIKON 5554-0102 BULB
NIKON 78589 BULB
NIKON DS-EPI-FL2 BULB
NIKON EPI FL BULB LAMP
NIKON LABOPHOT-2 MAIN
NIKON PHOTOLAB II BULB
OLYMPUS 8-B192 BULB
OLYMPUS 8229 BULB
OLYMPUS 8B192
OLYMPUS BH RFL BULB
OLYMPUS BH2-RFC BULB
OLYMPUS BH2-RFL BULB
OLYMPUS BX40F BULB
OLYMPUS IMTZ-RFL BULB
OM100W2L2
OM100WL2
OPTI QUIP 1500 BULB
OPTI QUIP BA-005 BULB
ORC AHD-100 BULB LAMP
OSRAM 1 X HBO 100 W/2
OSRAM 69217
OSRAM 69217-0
OSRAM 692170
OSRAM BULBS HBO 100W/2
OSRAM HB0100 W/2
OSRAM HBO 100 W/2
OSRAM HBO 100W/2
OSRAM HBO100W/2
OSRAM LAMP HBO 100 W/2
OSRAM LAMP HBO100W/2
OSRAM REPLACEMENT HBO100W2
OSRAM SYLVANIA 69217 BULB
OSRAM SYLVANIA HBO100W/2
PHILIPS CS100W/2 BULB
PLASMARC 100-5052 BULB
QL-0102/05
REICHERT M5000/133 BULB
SFA7,5-2 OSRAM
SYLVANIA 69217
SYLVANIA HBO 100 W/2
SYLVANIA HBO 100W/2
UPC 4050300507095
UPC LER38445
UPC: 4050300507095
UPC: LER38445
UPC:4050300507095
UPC:LER38445
VAN BRAUGHT HSA 100 BULB
WETZLAR 2087 BULB LAMP
WETZLAR 2087-001 BULB
WETZLAR 3040-0380 BULB
WETZLAR 500-138 BULB
WETZLAR DMRBE BULB
WILD 2087 BULB LAMP
WILD 2087-001 BULB
WILD 3040-0380 BULB
WILD 500-138 BULB
WILD DMRBE BULB
XENON L 117 BULB LAMP
XENON LM/100-2 BULB
ZEISS 1007-975 BULB
ZEISS 2800-18-4060D
ZEISS 38-00-18-4050
ZEISS 38-00-18-4060
ZEISS 38-00-18-4060D
ZEISS 38-02-13 BULB
ZEISS 38-16-13 BULB
ZEISS 38-16-16 BULB
ZEISS 3800-18-4050
ZEISS 3800-18-4060
ZEISS 3800184060
ZEISS 381613
ZEISS 9108491003
ZEISS AXIOSCOPE BULB LAMP

 
*Discontinued – subject to stock on hand Click HERE for more Bulb info.
Light bulbs in microscope illuminators need to be replaced periodically. The bulbs on this page are most commonly used in Meiji Techno illumination systems. If you own a Meiji microscope and need a replacement, you should be able to purchase it at your local Meiji Dealer. Some older models or specialized microscopes may use bulbs that are not listed here. If you cannot find the correct bulb, please contact our technical support staff to assist you. Click HERE for information on Lamp Safety, Handling and Disposal.
Tips on extending bulb life
Bulbs have a rough life in a microscope: burning in an enclosed area for hours on end with a finite lifetime, the effects of too much heat and not enough ventilation, DC current from the dimmer circuit slowly thinning the metal of the filament. And with bulbs nowadays being manufactured more and more cheaply, the cumulative effect is not good for bulb longevity.
If the bulb is halogen or DC Arc Lamp type, DO NOT TOUCH THE GLASS with your bare hands when installing bulbs. Use the plastic bag it comes in to install the bulb. DO NOT jar or bump or run your scope in an environment that has excessive vibration. Turn your scope off if you do not need it on. Some bulbs have a rated life of only 100 – 200 hours so if you use your scope full time, be prepared to use bulbs.
Halogen bulbs in microscopes and fiber optic light sources can also have problems if the socket is worn out; i.e. the connection cannot sink enough heat away from the bulb and/or the electrical connection is weak. If your scope is an old workhorse who's starting to eat bulbs, check the bulb socket out for poor contact and discoloration of the contact. The bi-pin type bulb should push stiffly into the socket. If not, or if it wobbles around excessively, the socket is too old and needs replacement.

Specifications

BAS-20SP Info:20mm straight drop down post for FA-3 or BAS-2 stands 4" in length
Product Information:    • Manufactured: 100% MADE IN U.S.A    • Warranty: LIMITED LIFETIME WARRANTY    • Customer Support: 1-(800) 832-0060 (U.S.A Based) Package Information:    • Weight: TBA    • Box Size: TBA