Replacement Bulbs Listed by Part Number
NOTE: The size of these images will vary and some images have been re-sized to fit this page. Do not rely on the size of these images to determine which bulb you need. NOTE: Incident light shines down from above; transmitted light shines up through the specimen from below.
MA111
MA260/05
MA261/SL-10
MA263/05 MA263/10
MA264/05
MA275/05
Part Number
Description
Application
MA111
12V 10W
Incident light:ST-3, SKT-1B, SKT-2B, SKT-3B, GS2000 Incident & transmitted light: SKT-BT, SKT-2BT, SKT-3BT Transmitted light: STC-3
MA260/05
6V 20W Halogen
For MA260, MA264H, and MA264EX illuminators
MA261/SL-10
115V 20W
For "B" Stand and MA261/35 (TM200 Series illuminator)
MA263/05
115V 30W
For MA263 illuminators
MA263/10
220/240V 30W
For MA263 illuminators
MA264/05
6.5V 2.75A
For MA264 illuminators
MA275/05
12V 50W
For ML5000 Series 50W models; ML7500, ML8500 All MT7500, MT8500 series
MA305/05
MA309/05
MA326
MA350/10 MA350/20
MA361/10 MA362/10
Part Number
Description
Application
MA305/05
8W Ring Fluorescent
For MA305/100, MA305/200 ring fluorescent illuminators
MA309/05
4W Tube Fluorescent
For MA309 fluorescent box illuminators for GEM stand
MA326
6V 30W Halogen (G4 base type)
For ML2000 and ML5000 Series 30W models; all VT Series Models, IM7100, IM7200, ML2000, ML7000, ML8000, ML9000, TC5100, TC5200, TC5300, TC5400, TC5500, TC5600 All MT Series 30W models; all RZT & RZDT Stands
MA350/10
115V 30W
For GEM stand transmitted light
MA350/20
220/240V 30W
For GEM stand transmitted light
MA361/10*
110V 20W
Half-silvered bulb for TM400 Series 20W models (DISCONTINUED)
MA361/20*
220/240V 20W
Half-silvered bulb for TM400 Series 20W models
MA362/10*
115V 30W
Half-silvered bulb for TM400 Series 30W models (DISCONTINUED)
MA362/20*
220/240V 30W
Half-silvered bulb for TM400 Series 30W models(DISCONTINUED)
MA560
MA561
MA570
FL180/70 FL150/70
MA357
MA358
MA590
Part Number
Description
Application
MA560
6V 1.2A Tungsten
Incident light: AB, ABZ, PB Stands All BM/BMK Series models
MA561
6V 1.2A Tungsten
Transmitted light: AB, ABZ, PB Stands
Note: MA560 and MA561 may appear to be identical, but they are not interchangeable.
MA570
6V 10W Halogen
Incident & transmitted light: ABE, ABH, ABZH, PBH Stands
FL150/70
21V 150W Halogen
For Fiber Optic Light sources: All FT190 and FL150 Series
FL180/70
21V 150W Halogen
For FL180, FL181 & FL182 fiber optic illuminators
MA357
8V 12W Tungsten
Frosted – Fits Meiji Techno MT5500 Series Microscopes
MA358
8V 12W Tungsten
Clear – Fits Meiji Techno MT5500 Series Microscopes
MA590
110V 15W Tungsten
Frosted – Fits Meiji Techno PBM Series Stands
DC Arc Lamps
Part Number
Description
Application
BA005
HBO 100W Mercury DC Arc Lamp
TC5000 Series & MT6000 Series Equipped with Epi-Fluorescence Lamphouses
BA013
XBO 75W Xenon DC Arc Lamp
BA014
XBO 100W Xenon DC Arc Lamp
BA005 Information:
Brand: Ushio Technology: Short-Arc Mercury Useful Life Hours: 200 Lumen Output: 2200 Actual Wattage: 100 Voltage: 20 Base Type: SFa7.5+SFa9 Length (Inch): 3.54 Diameter (Inch): .394Manufacturers Notes: The HBO 100W BA005 is a Mercury Arc 20V 100 W Lamp with a SFa7.5-2 base
This product is also a direct replacement for the following items:
100W OSRAM HBO MICROSCOPE
4050300507095
ALB UPC LER38445
ALB UPC: LER38445
ALB UPC:LER38445
AMERICAN OPTICAL 2087 BULB
DENTSPLY ULTRA CURE 100
EFOS ULTRA CURE 100
EFOS ULTRA CURE 100 BULB
HANOVIA HGH100W2 BULB
HBO 100W/2
HBO 100W/2 BULBS
HBO 100W/2 LIGHT BULB
HBO 100W/2 MERCURY LAMP
HBO 100W/2 OSRAM BULB
HBO 100W/2 OSRAM BULBS
HBO.100W.2
HBO100W/2
HBO100W/2 BULB
HBO100W/2 LAMP
HBO100W/L2
HBO100W2
JENA HBO 101/2 BULB
LD CAULK ULTRA CURE 100
LEICA 2087
LEICA 2087 BULB LAMP
LEICA 2087-001 BULB
LEICA 3040-0380 BULB
LEICA 500-138 BULB
LEICA 500138
LEICA DMRBE BULB
LEITZ 2087 BULB
LEITZ 2087-001 BULB
LEITZ 3040-0380 BULB
LEITZ 500-138
LEITZ 500-138 BULB LAMP
LEITZ DMRBE BULB LAMP
LER38445
LITE SOURCE LS-97 BULB
M5000-133
MICROSTAR IV MICROSCOPE
MICROVISION 804-137-001
MITEY LITE AMERICAN OPT
NARVA HBO 101/2 BULB
NIKON 1996G7 BULB
NIKON 235915 BULB
NIKON 5554-0102 BULB
NIKON 78589 BULB
NIKON DS-EPI-FL2 BULB
NIKON EPI FL BULB LAMP
NIKON LABOPHOT-2 MAIN
NIKON PHOTOLAB II BULB
OLYMPUS 8-B192 BULB
OLYMPUS 8229 BULB
OLYMPUS 8B192
OLYMPUS BH RFL BULB
OLYMPUS BH2-RFC BULB
OLYMPUS BH2-RFL BULB
OLYMPUS BX40F BULB
OLYMPUS IMTZ-RFL BULB
OM100W2L2
OM100WL2
OPTI QUIP 1500 BULB
OPTI QUIP BA-005 BULB
ORC AHD-100 BULB LAMP
OSRAM 1 X HBO 100 W/2
OSRAM 69217
OSRAM 69217-0
OSRAM 692170
OSRAM BULBS HBO 100W/2
OSRAM HB0100 W/2
OSRAM HBO 100 W/2
OSRAM HBO 100W/2
OSRAM HBO100W/2
OSRAM LAMP HBO 100 W/2
OSRAM LAMP HBO100W/2
OSRAM REPLACEMENT HBO100W2
OSRAM SYLVANIA 69217 BULB
OSRAM SYLVANIA HBO100W/2
PHILIPS CS100W/2 BULB
PLASMARC 100-5052 BULB
QL-0102/05
REICHERT M5000/133 BULB
SFA7,5-2 OSRAM
SYLVANIA 69217
SYLVANIA HBO 100 W/2
SYLVANIA HBO 100W/2
UPC 4050300507095
UPC LER38445
UPC: 4050300507095
UPC: LER38445
UPC:4050300507095
UPC:LER38445
VAN BRAUGHT HSA 100 BULB
WETZLAR 2087 BULB LAMP
WETZLAR 2087-001 BULB
WETZLAR 3040-0380 BULB
WETZLAR 500-138 BULB
WETZLAR DMRBE BULB
WILD 2087 BULB LAMP
WILD 2087-001 BULB
WILD 3040-0380 BULB
WILD 500-138 BULB
WILD DMRBE BULB
XENON L 117 BULB LAMP
XENON LM/100-2 BULB
ZEISS 1007-975 BULB
ZEISS 2800-18-4060D
ZEISS 38-00-18-4050
ZEISS 38-00-18-4060
ZEISS 38-00-18-4060D
ZEISS 38-02-13 BULB
ZEISS 38-16-13 BULB
ZEISS 38-16-16 BULB
ZEISS 3800-18-4050
ZEISS 3800-18-4060
ZEISS 3800184060
ZEISS 381613
ZEISS 9108491003
ZEISS AXIOSCOPE BULB LAMP
*Discontinued – subject to stock on hand Click HERE for more Bulb info.
Light bulbs in microscope illuminators need to be replaced periodically. The bulbs on this page are most commonly used in Meiji Techno illumination systems. If you own a Meiji microscope and need a replacement, you should be able to purchase it at your local Meiji Dealer. Some older models or specialized microscopes may use bulbs that are not listed here. If you cannot find the correct bulb, please contact our technical support staff to assist you. Click HERE for information on Lamp Safety, Handling and Disposal.
Tips on extending bulb life
Bulbs have a rough life in a microscope: burning in an enclosed area for hours on end with a finite lifetime, the effects of too much heat and not enough ventilation, DC current from the dimmer circuit slowly thinning the metal of the filament. And with bulbs nowadays being manufactured more and more cheaply, the cumulative effect is not good for bulb longevity.
If the bulb is halogen or DC Arc Lamp type, DO NOT TOUCH THE GLASS with your bare hands when installing bulbs. Use the plastic bag it comes in to install the bulb. DO NOT jar or bump or run your scope in an environment that has excessive vibration. Turn your scope off if you do not need it on. Some bulbs have a rated life of only 100 – 200 hours so if you use your scope full time, be prepared to use bulbs.
Halogen bulbs in microscopes and fiber optic light sources can also have problems if the socket is worn out; i.e. the connection cannot sink enough heat away from the bulb and/or the electrical connection is weak. If your scope is an old workhorse who's starting to eat bulbs, check the bulb socket out for poor contact and discoloration of the contact. The bi-pin type bulb should push stiffly into the socket. If not, or if it wobbles around excessively, the socket is too old and needs replacement.
|