ML6120 Halogen Binocular Asbestos PLM Microscope [DISCONTINUED]

DISCONTINUED ON 6/17/2019

The ML6120 is replaced with the ML6120L.

Polarizing PLM (Polarized Light ) Microscope for Asbestos fiber identification applications. Meiji manufactures these microscopes pursuant to NIOSH 9002 Reference methods, with strain free condenser and dispersion staining objectives and transmitted Koehler illuminator with 6V 30W Halogen lamp with variable intensity control. Made In Japan

Locate a DealerGet a Quote

SKU: ml6120_halogen_binocular_asbestos_plm_microscope Categories: , , ,

Description

The ML6100 Series features include:

  • DIN standard eyepiece HWF10X and DIN focusing HWF10XF eyepiece with crossline reticle
  • SM Plan DIN strain free Brightfield POL objectives, 10X, 20X, 40X
  • SM Plan Dispersion staining objective 10X
  • Rotatable stage with graduation 360° with vernier readings
  • Strain free achromatic condenser NA 1.25 with Iris, filter holder
  • Rotatable polarizer in swing-out mount, analyzer
  • Built-in Koehler illuminator with 6V 30W Halogen lamp & variable intensity control
  • Compensator Plate: First order red plate c.550 nm
  • Blue daylight filter (MA289/05, 29.8mm diameter)
  • Bertrand lens in sliding mount
  • Centerable quadruple nosepiece with centering screws
  • Coaxial coarse and fine adjustment with graduations
  • Binocular or Trinocular head inclined at 30° degrees

PLM (Polarizing Light Microscopy):
This method is useful for the qualitative identification of asbestos and the semi-quantitative determination of asbestos in bulk samples. This method measures the percentage of asbestos as perceived by the analyst in comparison to standard projections, photographs and experience. The quality of the results are dependant upon the skill and judgment of the operator. The ML6100 Series falls under the Meiji Techno America’s pursuant to NIOSH 9002 Reference methods, with strain free condenser and dispersion staining objectives and transmitted Koehler illuminator with 6V 30W Halogen lamp with variable intensity control.

Additional information

Weight 1.0000 kg
Components & Accessories

Included:    • ML6120: Binocular Polarizing PLM (Polarized Light ) Microscope for Asbestos fiber identification applications.  Meiji manufactures these microscopes pursuant to NIOSH 9002 Reference methods, with strain free condenser and  dispersion staining objectives and transmitted Koehler illuminator with 6V 30W Halogen lamp with variable intensity control    • MA647: Binocular head, 30° inclination. One eye tube slotted for orientation of cross-line focusing eyepiece dual graduated diopter eyetubes with interpupillary adjustments of 52mm to 72mm. One eyetube slotted for 90° and 45°orientation of cross-line eyepiece    • MA406: DIN HWF10X eyepiece, FN 18mm (each)    • MA413: CP DIN focusing HWF10X eyepiece with cross-line and guide pin (each)    • Nosepiece: Quadruple ball-bearing with one fixed and three centerable objective apertures    • MA642: SM Plan strain free objective 10X/N.A.0.25    • MA642D: SM Plan 10X dispersion staining objective    • MA643: SM Plan strain free objective 20XS/N.A.0.40    • MA644: SM Plan strain free objective 40XS/N.A.0.65    • Stage: Rotatable stage with Vernier graduation 360° with Vernier, reading to 1°, 150mm diameter with stainless steel stage clips (Factory Installed)    • Focusing Adjustment: Coaxial coarse and fine focusing controls with graduation reading 2 microns power division.  Incorporates tension adjustment and safety Auto-focus stage stop lever    • MA326: Halogen bulb 6V 30W, replacement (Factory Installed)         • MA327: Fuse 3Amp, replacement (Factory Installed)    • MA470: First order red compensating plate in sliding mount    • MA471: Analyzer in sliding mount for E-W insertion for ML6100 Series    • MA477: Bertrand lens in sliding mount with field limiting stop for ML6100 Series    • MA665: Strain free achromatic polarizing condenser N.A. 1.25 with iris diaphragm and filter tray    • Polarizer: Swing in-out click/clamp mount, fully rotatable 360° with click stop at 0°and 90°    • MA712: Dust cover for ML6100 Series    • Manual: Meiji Techno America ML6100 Manual OPTIONAL COMPONENTS & ACCESSORIES BELOW Viewing Heads:    • MA648: Trinocular head, 30° inclination. One eyetube slotted for orientation of cross-line eyepiece, but with 80%/20% beam-splitter and vertical phototube (Included with ML9430)    • MA656: Binocular head, erect image   • MA666: Trinocular head, erect image (100% cutoff of left eyetube occurs when the beam splitter is moved into position)   • MA649: Monocular head, 30° inclination. One eyetube slotted for 90° and 45°orientation of cross-line eyepiece POL Objectives:    • MA641: SM Plan strain free objective 4X/N.A.0.10    • MA645: SM Plan strain free objective 60XS/N.A.0.85    • MA646: SM Plan strain free objective 100XS/N.A.1.25 oil POL Objectives for Incident Light Work:    • MA724: SM Plan M20X objective NA 0.40, 160/0    • MA725: SM Plan M40X objective NA 0.65, 160/0 Stage:    • MA299: Attachable mechanical stage for MT9000 or MT9900 Series Bulbs and Fuses:    • MA326: Halogen bulb 6V 30W, replacement     • MA327: Fuse 3Amp, replacement

Downloads

Double click to read at full screen Download Brochure (PDF)

Double click to read at full screen Download Manual (PDF)

Magnification

Eyepieces:    • MA406: DIN HWF10X eyepiece, FN 18mm (each) (INCLUDED)    • MA413: CP DIN focusing HWF10X eyepiece with cross-line and guide pin (each) (INCLUDED) POL Objectives:    • MA641: SM Plan strain free objective 4X/N.A.0.10 (INCLUDED)    • MA642: SM Plan strain free objective 10X/N.A.0.25 (INCLUDED)    • MA642D: SM Plan 10X dispersion staining objective (INCLUDED)    • MA643: SM Plan strain free objective 20XS/N.A.0.40    • MA644: SM Plan strain free objective 40XS/N.A.0.65 (INCLUDED)    • MA645: SM Plan strain free objective 60XS/N.A.0.85    • MA646: SM Plan strain free objective 100XS/N.A.1.25 oil

Specifications

Includes:    • ML6120: Binocular Polarizing PLM (Polarized Light ) Microscope for Asbestos fiber identification applications.  Meiji manufactures these microscopes pursuant to NIOSH 9002 Reference methods, with strain free condenser and  dispersion staining objectives and transmitted Koehler illuminator with 6V 30W Halogen lamp with variable intensity control    • MA647: Binocular head, 30° inclination. One eye tube slotted for orientation of cross-line focusing eyepiece dual graduated diopter eyetubes with interpupillary adjustments of 52mm to 72mm. One eyetube slotted for 90° and 45°orientation of cross-line eyepiece    • MA406: DIN HWF10X eyepiece, FN 18mm (each)    • MA413: CP DIN focusing HWF10X eyepiece with cross-line and guide pin (each)    • Nosepiece: Quadruple ball-bearing with one fixed and three centerable objective apertures    • MA642: SM Plan strain free objective 10X/N.A.0.25    • MA642D: SM Plan 10X dispersion staining objective    • MA643: SM Plan strain free objective 20XS/N.A.0.40    • MA644: SM Plan strain free objective 40XS/N.A.0.65    • Stage: Rotatable stage with Vernier graduation 360° with Vernier, reading to 1°, 150mm diameter with stainless steel stage clips (Factory Installed)    • Focusing Adjustment: Coaxial coarse and fine focusing controls with graduation reading 2 microns power division.  Incorporates tension adjustment and safety Auto-focus stage stop lever    • MA326: Halogen bulb 6V 30W, replacement (Factory Installed)         • MA327: Fuse 3Amp, replacement (Factory Installed)    • MA470: First order red compensating plate in sliding mount    • MA471: Analyzer in sliding mount for E-W insertion for ML6100 Series    • MA477: Bertrand lens in sliding mount with field limiting stop for ML6100 Series    • MA665: Strain free achromatic polarizing condenser N.A. 1.25 with iris diaphragm and filter tray    • Polarizer: Swing in-out click/clamp mount, fully rotatable 360° with click stop at 0°and 90°    • MA712: Dust cover for ML6100 Series    • Manual: Meiji Techno America ML6100 Manual    • Warranty: Limited Lifetime Warranty Card  Product Information:    • Manufactured: 100% MADE IN JAPAN    • Warranty: LIMITED LIFETIME WARRANTY    • Customer Support: 1-(800) 832-0060 (U.S.A Based) Package Information:    • Weight: 31.0 lbs (8.5 kg)    • Box Size: 22 x 16 x 14 inches    • Footprint: 254mm (D) x 203mm (W)    • Monocular head type: 270 mm(D) x 435 mm (H) x 200mm(W) 30.0 lbs. (8.2 kg)    • Binocular head type: 270 mm(D) x 435 mm (H) x 200mm(W) 31.0 lbs. (8.4 kg)    • Trinocular head type: 270 mm(D) x 480 mm (H) x 200mm(W) 32.0 lbs. (8.7 kg)

Model

Head

Illumination

Eyepieces

Objectives

Stage

Condenser

ML6110(DISCONTINUED)

Monocular

Koehler Illuminator 6V 30W halogen with variable intensity control

HW10X-F DIN Focusing eyepiece with crossline reticle

SM Plan DIN strain free brightfield POL. 10X, 20X, 40XS and 10X central stop dispersion staining objectives

Rotatable stage with 360 graduations and vernier

Strain Free Achromatic condenser NA 1.25 with iris and filter holder

ML6120(DISCONTINUED)

Binocular

HWF10x and HW10X-F DIN Focusing eyepiece with crossline reticle

ML6130(DISCONTINUED)

Trinocular