ML2600 Halogen Binocular Brightfield Biological Microscope [DISCONTINUED]

DISCONTINUED ON 6/17/2019

The ML2600 is replaced with the upgraded LED model: ML2600L


The Meiji Techno ML2600 Binocular Brightfield Biological Laboratory Series is one of our most rugged fully equipped microscope systems from Japan with a Flat-top Mechanical Stage and forward facing nosepiece. It offers many high performance features and a stable rectangular base for stability. High resolution DIN Standard Planachromat objectives offer crisp, clear, high contrast images and are offered as part of the standard package. A built in integrated Koehler illuminator with a field iris and 6V 30W Halogen lamp and variable intensity control is provided standard equipment to complement the Planachromat optics. A green monitor lamp is lit to indicate that the lamp is on for easy on/off recognition in any laboratory setting. The low voltage, high intensity, pre-centered halogen lamp provides high level illumination can be adjusted to maximize the evenness of the bulb illumination and is readily accessible for a quick bulb replacement. The ML2600 Series also features a specially designed Achromatic N.A. 1.25 condenser with iris diaphragm and filter carrier. The die cast metal stand has a chemical resistant finish and is the most rugged, durable finish in the market today. Equipped with low position factory calibrated coaxial coarse and fine focus controls, tension adjustment and a built in stage stop lever to protect the specimen and objectives from accidental damage during use. The ML2600 Series Laboratory Biological Microscope is a versatile and modular system designed to accept a wide variety of optional accessories and is backed by Meiji Techno’s Limited Lifetime Warranty.
Made In Japan

Includes:
• ML2600: The ML2600 is a Brightfield Binocular Laboratory Compound microscope with Koehler Halogen 6V 30W illumination with forward facing quadruple ball bearing nosepiece. High resolution DIN Standard Plan objectives offer crisp, clear, high contrast images and are offered as part of the standard package. A built in integrated Koehler illuminator with a field iris and 6V 30W Halogen lamp and variable intensity control is provided standard equipment to complement the Planachromat optics. The low voltage, high intensity, pre-centered halogen lamp provides high level illumination can be adjusted to maximize the evenness of the bulb illumination and is readily accessible for a quick bulb replacement. Flat-Top Mechanical stage with 171mm and 140mm rectangular stage with movement of 78mm (X) x 52mm (Y) with drop down Ergonomically placed low positioned coaxial controls and a detachable specimen guide.
MA602: Inclined Binocular head Inclined at 30°, 360° rotatable, dual graduated diopter eyetubes with interpupillary adjustments 52mm to 72mm


MA406 qty#2: DIN HWF10X eyepiece, Field No. 18, (each)


MA622: 4X/0.10 Planachromat objective, Non-Infinity 160mm Tube Length
MA623: 10X/0.25 Planachromat objective, Non-Infinity 160mm Tube Length
MA625: 40X/0.65 Planachromat objective, spring loaded, Non-Infinity 160mm Tube Length
MA627: 100X/1.25 Planachromat objective, spring loaded, Non-Infinity 160mm Tube Length
MA661: Achromatic substage condenser 1.25 NA with iris diaphragm and 30mm filter tray


Stage: Mechanical X-Y stage with attached finger assembly and drop down post, attached stage is 120mm x 140mm rectangular mechanical stage with movements of 75mm (X) x 40mm (Y) and is graduated with Vernier readings to 0.1mm, equipped with low positioned drop down coaxial controls. (Factory Installed)

stage


• Focusing Adjustment: Coaxial coarse and fine focusing controls with graduation reading 2 microns power division. Incorporates tension adjustment and safety Auto-focus stage stop lever

focusing adjectment


MA289/05: Blue filter, clear, 29.8mm diameter
MA676: Attachable clinical specimen holder for MA596R and MA596L
MA596L: Flat-top stage with clinical specimen holder, 78mm X 52mm, X-Y movement, with drop-down coaxial controls (Left) for models ML2400,
ML2500, ML2700, ML2850, ML2950 and ML5000 series
MA326: Bulb 6V 30W Halogen ( Factory Installed)
MA327: Fuse 3Amp (Factory Installed)
MA700: Immersion Oil. 15cc
MA701: Dust Cover for ML2000
Manual: Meiji Techno America ML2000 Manual
Warranty:Limited Lifetime Warranty Card 

Product Information:
   • Manufactured: 100% MADE IN JAPAN
   • Warranty: LIMITED LIFETIME WARRANTY
   • Customer Support: 1-(800) 832-0060 (U.S.A Based)

Package Information:
   • Weight: 21.0 lbs (9.5 kg)
   • Box Size: 22 x 16 x 23 inches
   • Footprint: 254mm (D) x 203mm (W)
   • Binocular head type: 255 mm(D) x 395 mm (H) x 195mm(W) 21.0 lbs. (9.5kg)
   • Trinocular head type: 255 mm(D) x 440 mm (H) x 195mm(W) 22.0 lbs. (10.0kg)

Model
Head
Illumination
Eyepieces
Condensers
Objectives
Stage

ML2200
(DISCONTINUED)

Binocular
Koehler 6V 30W halogen
KWH10x FN22
Plan Epi BD 5x, 10x, 20x, 50x
SM.Plan Brightfield 4x,10x, S40x, S100x oil
Attached

ML2300
(DISCONTINUED)

Trinocular

ML2400
(DISCONTINUED)

Binocular
Flat-Top

ML2500
(DISCONTINUED)

Trinocular

ML2600
(DISCONTINUED)

Binocular
Planachromat Brightfield 4x, 10x, S40x, S100x oil

ML2700
(DISCONTINUED)

Trinocular

VIEWING HEADS
Available with standard binocular heads or trinocular heads for photomicrography, 30° inclined eyetubes with adjustable diopter settings and interpupillary distance, 360° rotatable.

EYEPIECES
Paired DIN KHW10x, FN 20.

OBJECTIVES CHANGER
Smooth-operating, ball bearing mounted, quadruple nosepiece.

OBJECTIVES
S. Flat Achromats, SM Planachromats, Planachromats, or Phase Contrast.

STAND
Attached mechanical stage: 120mm x 140mm surface with 75mm (X) by 40mm (Y) movement, graduated with vernier readings to 0.1 mm, drop-down right or left-handed controls. Flat-top stage: 171mm x 140mm surface with 80mm (X) by 52mm (Y) movement, graduated with vernier readings to 0.1 mm, detachable specimen guide, drop-down right of left-handed controls.

CONDENSERS
Standard models have either an Achromatic NA 1.25 condenser with iris diaphragm and filter tray for brightfield work, simple NA 1.25 slider phase condenser, or an NA 1.25 Zernike phase condenser with filter tray and independently centerable annuli for phase contrast. Cardioid-type NA 1.25 darkfield condenser for high power (100x objective only) darkfield work is optional.

ILLUMINATION
Built-in, 6V 30W, variable-intensity Koehler illumination for apertures up to 1.25.

PHOTOMICROGRAPHY
Meiji Techno offers a broad range of digital video cameras which offers excellent sensitivity, high resolution and a wide dynamic range for the most demanding brightfield and darkfield microscopy applications including clinical pathology and cytology, life sciences and geology. Some models has included software, that can preview and capture still shots and live videos to a PC or Mac with USB port or HDMI connectivity.

Details

The ML2000 Series features include:

  • Transmitted light Binocular microscope with DIN standard eyepieces with 20mm field of view, 22mm eye relief
  • Binocular head is inclined at 30° degrees and rotatable 360° degrees
  • Dual graduated diopter eyetubes with interpupillary adjustments of 52mm to 72mm
  • Trinocular models has a sliding beam splitter that directs 100% of the light to the eyepieces or 80% to the camera and 20% to the eyepieces
  • Forward facing, quintuple ball bearing smooth operating, revolving nosepiece
  • SM Plan Objectives, 160mm Tube length, Non-Infinity objectives
  • Rectangular attached Mechanical stage with 75mm (X) and 40mm (Y) movement
  • Adjustable slide holder graduations and vernier reading to 0.1mm
  • Achromatic N.A. 1.25 condenser with iris diaphragm and filter carrier
  • Coaxial coarse and fine focus adjustment with graduation, reading 2 microns per division with tension adjustment and safety auto focus stop
  • Built-in Koehler illuminator with 6V 30W halogen lamp & variable intensity control

Brightfield:
The simplest of all the optical microscopy illumination techniques. Sample illumination is transmitted (i.e., illuminated from below and observed from above) white light and contrast in the sample is caused by absorbance of some of the transmitted light in dense areas of the sample. Brightfield microscopy is the simplest of a range of techniques used for illumination of samples in light microscopes and its simplicity makes it a popular technique. The typical appearance of a brightfield microscopy image is a dark sample on a bright background.

The ML2200 Series has a Koehler Halogen 6V 30W illumination with forward facing quintuple ball bearing nosepiece. High resolution DIN Standard SM Plan objectives offer crisp, clear, high contrast images and are offered as part of the standard package. A built in integrated Koehler illuminator with a field iris and 6V 30W Halogen lamp and variable intensity control is provided standard equipment to complement the SM PLAN optics. The low voltage, high intensity, pre-centered halogen lamp provides high level illumination can be adjusted to maximize the evenness of the bulb illumination and is readily accessible for a quick bulb replacement. With a rectangular attached mechanical stage.

Components & Accessories

Included:
• ML2600: The ML2600 is a Brightfield Binocular Laboratory Compound microscope with Koehler Halogen 6V 30W illumination with forward facing quadruple ball bearing nosepiece. High resolution DIN Standard Plan objectives offer crisp, clear, high contrast images and are offered as part of the standard package. A built in integrated Koehler illuminator with a field iris and 6V 30W Halogen lamp and variable intensity control is provided standard equipment to complement the Planachromat optics. The low voltage, high intensity, pre-centered halogen lamp provides high level illumination can be adjusted to maximize the evenness of the bulb illumination and is readily accessible for a quick bulb replacement. Flat-Top Mechanical stage with 171mm and 140mm rectangular stage with movement of 78mm (X) x 52mm (Y) with drop down Ergonomically placed low positioned coaxial controls and a detachable specimen guide.
• MA602: Inclined Binocular head Inclined at 30°, 360° rotatable, dual graduated diopter eyetubes with interpupillary adjustments 52mm to 72mm
• MA406 qty#2: DIN HWF10X eyepiece, Field No. 18, (each)
• MA622: 4X/0.10 Planachromat objective, Non-Infinity 160mm Tube Length
• MA623: 10X/0.25 Planachromat objective, Non-Infinity 160mm Tube Length 
• MA625: 40X/0.65 Planachromat objective, spring loaded, Non-Infinity 160mm Tube Length 
• MA627: 100X/1.25 Planachromat objective, spring loaded, Non-Infinity 160mm Tube Length 
• MA661: Achromatic substage condenser 1.25 NA with iris diaphragm and 30mm filter tray
• Stage: Mechanical X-Y stage with attached finger assembly and drop down post, attached stage is 120mm x 140mm rectangular mechanical stage with movements of 75mm (X) x 40mm (Y) and is graduated with Vernier readings to 0.1mm, equipped with low positioned drop down coaxial controls. (Factory Installed)
• Focusing Adjustment: Coaxial coarse and fine focusing controls with graduation reading 2 microns power division. Incorporates tension adjustment and safety Auto-focus stage stop lever
• MA289/05: Blue filter, clear, 29.8mm diameter
• MA676: Attachable clinical specimen holder for MA596R and MA596L 
• MA596L: Flat-top stage with clinical specimen holder, 78mm X 52mm, X-Y movement, with drop-down coaxial controls (Left) for models ML2400,
ML2500, ML2700, ML2850, ML2950 and ML5000 series
• MA326: Bulb 6V 30W Halogen ( Factory Installed)
• MA327: Fuse 3Amp (Factory Installed)
• MA700: Immersion Oil. 15cc
• MA701: Dust Cover for ML2000 
• Manual: Meiji Techno America ML2000 Manual 

OPTIONAL COMPONENTS & ACCESSORIES BELOW

Viewing Heads:
   • MA603: Inclined Trinocular head
   • MA657: Binocular head erect image
   • MA403: Inclined Monocular head

Eyepieces:
   • MA407: DIN KHW10X compensating eyepiece, Field No. 20 (ea) (Accepts 21mm reticle)
   • MA407/05: DIN KHW10X-F compensating focusing eyepiece, Field No. 20 (ea) (Accepts 21mm reticle)
   • MA408: DIN HWF15X eyepiece, Field No. 9 (ea)
   • MA409: DIN HWF20X eyepiece, Field No. 9 (ea)

SM Semi Planachromat Objectives:
   • MA611: 4X/0.10 SM Semi Planachromat objective W.D. 19.83mm, 160mm Tube Length
   • MA613: 10X/0.25 SM Semi Planachromat Objective W.D. 6.23mm, 160mm Tube Length
   • MA615: 40X/0.65 SM Semi Planachromat Objective, spring loaded, W.D. 0.72mm, 160mm Tube Length
   • MA617: 100X/1.25 SM Semi Planachromat Objective, spring loaded, W.D. 0.12mm, 160mm Tube Length 
   • MA612: 5X/0.12 SM Semi Planachromat objective, W.D. 19.83mm
   • MA692: 20X/0.40 BF Semi Planachromat objective, W.D. 6.1mm
   • MA693: 40X/0.65 BF Semi Planachromat objective, spring loaded, W.D. 0.43mm
   • MA694: 50X/0.95 BF Semi Planachromat objective, spring loaded, oil, W.D. 0.25mm
   • MA696: 100X/ 1.25 BF Semi Planachromat objective, spring loaded, oil, W.D. 0.15mm
   • MA811: 50X/0.95 BF Semi Planachromat objective, oil with iris, W.D. 0.24mm
   • MA813: 100X/ 1.25 BF Semi Planachromat objective, oil with iris, W.D. 0.15mm

Planachromat Objectives:
   • MA432: 2.5X/0.08 Planachromat objective

Zernike BF Semi Plan Phase Objectives and Components (SET PH-A):
   • MA695: BF Plan Phase 10X/0.25 objective for use with Zernike type condenser
   • MA697: BF Plan Phase 20X/0.40 objective for use with Zernike type condenser
   • MA698: BF Plan Phase 40X/0.65 objective for use with Zernike type condenser
   • MA699: BF Plan Phase 100X/1.25 objective for use with Zernike type condenser
   • MA716: Zernike phase condenser N.A. 1.25 in turret mount, with centerable phase annuli for 10X, 20X, 40X with brightfield position with iris and filter tray for 29.8mm diameter filter and darkfield stop for use with 10X, 20X and 40X objectives
   • MA457/01: Extended centering screw for MA715 Phase condenser (Each)
   • MA458: Centering telescope
   • MA759: Green Interference filter 546nm, 29.8mm diameter

Darkfield-Oil Immersion Objectives/Condenser System:
   • MA811: BF Semi Planachromat 50X, N.A. 0.95, oil with iris diaphragm
   • MA813: 100X/ NA 1.25 BF Semi Planachromat objective with iris, W.D. 0.15mm
   • MA430: DIN S. Plan objective 100X, NA 1.25 oil w/iris
   • MA274: Darkfield condenser, Cardioid type, 1.2-1.33 NA (For use with 50X or 100X with iris only)

Darkfield Accessories:
   • MA278/05: Darkfield filter (central stop) for use with filter tray, 29.8mm diameter
   • MA674: Darkfield stop to fit MA661 Achromatic NA 1.25 condenser

Condensers:
   • MA661: Achromatic substage condenser 1.25 NA with iris diaphragm and 30mm filter tray
   • MA661/674: Achromatic substage condenser 1.25 NA with dry darkfield stop
   • MA716: Zernike Phase condenser, N.A. 1.25 with centerable Phase annuli for 10X, 20X, 40X with brightfield position with iris and filter tray for 29.8mm diameter filter and darkfield stop for use with 10X, 20X and 40X objectives
   • MA457/01: Extended centering screw for MA715 or MA716 Phase condenser analyzer to fit viewing head (Each)

Polarizers:
   • MA608: Polarizer set for ML2000 series (Polarizer to fit over 44mm lamphouse analyzer to fit viewing head)
   • MA608/05: Polarizer set for ML5400, ML5500, ML5850 & ML5950 (50W version) (Polarizer to fit over 37mm lamphouse, analyzer to fit viewing head)
   • MA608/10: Polarizer set for ML5000, ML5100, ML5200, ML5300, ML5800 & ML5900 (30W version) (Polarizer to fit over 44mm lamphouse analyzer to fit viewing head)

Filters:
   • MA196: ND50 neutral density filter, 29.8mm diameter
   • MA197: ND13 neutral density filter, 29.8mm diameter
   • MA290/05: Green filter, clear, 29.8mm diameter
   • MA759: Green Interference filter 546nm, 29.8mm diameter
   • MA291: Polarizing filter, 29.8mm diameter

Stages:
   • MA676: Attachable clinical specimen holder for MA596R and MA596L
   • MA595R: Graduated mechanical stage, 30mm X 70mm movement with drop-down coaxial controls (Right) for ML series ML2200, ML2300, ML2870 and ML2970
   • MA595L: Graduated mechanical stage, 30mm X 70mm movement with drop-down coaxial controls (Left) for RM series ML2200, ML2300, ML2800, ML2900
   • ML2000/PT#526: Replacement stage mounting plate
   • ML5000/PT#750: Replacement stage mounting plate

Eyepiece Micrometers (21mm Diameter) for use with MA407 Eyepiece:
   • MA284: Cross-line reticle, 21mm diameter
   • MA255: 10mm divided into 100 units, 21mm diameter
   • MA256: 5mm divided into 100 units, 21mm diameter
   • MA283/05: 10mm square into 100 parts, 1.0mm square, 21mm diameter
   • MA540: Cross-line with 0.1mm graduations, 21mm diameter

Stage Micrometers:
   • MA285: 1mm divided into 100 units, 0.01mm
   • MA286: 0.04” divided into 40 units, 0.001”

Bulbs and Fuses:
   • MA275/05: Spare bulb 12V 50W halogen (ML5400 & ML5500)
   • MA326: Spare bulb 6V 30W halogen (ML2000 & ML5000)
   • MA327: Fuse 3A

Miscellaneous:
   • MA200: Eyeshields for MA407 KHW10X eyepieces (Ea.)
   • MA700: Immersion Oil, 15cc
   • Pointer/ML: Eyepiece pointer


Double click to read at full screen
Download Brochure (PDF)



Double click to read at full screen
Download Manual (PDF)