MT6300CW-HD 100X-1000X Trinocular Epi-Fluorescence Biological Microscope with LED Light Source and HD Camera Monitor (HD1000-LITE-M)

This configuration system contain's Meiji Techno's MT6300CW and our HD camera called HD1000-LITE-M.

Meiji Techno's new MT6300CW Series trinocular laboratory grade upright are our new Biological(LED Epi-Fluorescence). The MT6300CW Series employs Meiji Techno's all new ICOS™ (Infinity Corrected Optical System) making the study of mounted specimens fast and easy while delivering an excellent cost-to-performance ratio. The MT6300CW Series microscopes are configured for Brightfield and Epi-flourescence but can also be outfitted with optional Phase contrast, Polarized light and Darkfield components. System modularity makes purchase and operation very affordable for colleges, universities, researchers and clinics.

Epi-Fluorescent with LED advantages, such as intensity from a conventional lamp decreases through its life, which means that illumination varies dramatically over time. The lifetime of LED’s far exceeds that of these older lamps, ex. Mercury, Metal Halide, Xenon models and intensity remains broadly constant throughout its life providing a stable, repeatable light source. Some of the many fluorophores excited by the PE-300 CoolLED add-on series are FITC, DAPI, Cy3, Auramine, TxRed, mCherry, TRITC, ChR, Hoechst, Cy5, Calcofluor, RFP to name a few. The MT6300CL is equipped with PE-300W/LEDMT which is a LED fluorescence illumination kit, configured for fluorophores such as DAPI, FITC, TRITC & Cy5, instant on/off with the ability to optimize intensity & minimize sample damage via the simple desktop Control Pod with a manual control pod and power supply. (Included in MT6200CW & MT6200ECW & MT6300CW & MT6300ECW models).

The HD1000-LITE-M is Meiji Techno America’s affordable HDMI /USB2.0 camera technology! It is the most economical HDMI & USB 2.0 camera in the market. You can easily operate the HD1000-LITE-M camera by directly connecting it to a monitor with a HDMI port without a PC. It can directly save images into an on-board SD-4G card on the camera or connect the camera directly to your PC as it has a standard USB 2.0 interface to utilize the full annotation/software function. The camera quickly reacts to lighting changes in any life science, clinical or material applications. With video output via HDMI connector, the setting menu allows easy access to feature settings.

NOTE for HD1000-LITE-M: 
• 5MP Still Capture resolution 2592 x 1944
• 1920 x 1080- 15fps (frame per second) /1080P HDMI via HDMI 
• 1920 x 1080 -15fps/1080p by USB 2.0) via USB 2.0 

Note: First decide on the Microscope model that fits your requirement, Binocular or Trinocular, or Ergo-Binocular or Ergo-Trinocular model. Secondly decide on the proper Meiji Techno CoolLED illumination unit for your application. 

Simple to Choose: No alignment or adjustment needed once installed, already configured for your everyday fluorophores such as DAPI, FITC, TRITC and Cy5 and affordable through your lab consumables budget. 

Simple to Fit: Direct fit means the CoolLED unit just attaches straight onto the microscope’s epi-fluoresence port in seconds which is optimized for light output for your microscope. 

Simple to Use: Instant On/Off with the ability to optimize intensity and minimize sample damage via the simple desktop Control Pod, really simple to fit and use immediately with less down time for set-up.


Made In Japan


Locate a DealerGet a Quote


cerohs

MT6300CW-HD (with HD1000-LITE-M)

MT6300CW-HD Trinocular Microscope with Epi-Fluorescence is an optical biological microscope that uses fluorescence and phosphorescence instead of, or in addition to, reflection and absorption to study properties of organic or inorganic substances. The “fluorescence microscope” refers to any microscope that uses fluorescence to generate an image, whether it is a more simple set up like an epifluorescence microscope, or a more complicated design such as a confocal microscope, which uses optical sectioning to get better resolution of the fluorescent image. Equipped with Chroma filters and a six position filter holder, there is a slot to add 3 more filter cubes and desired filters for your specific experiment or application. Intensity from a conventional lamp decreases through its life, which means that illumination varies dramatically over time. The lifetime of LED’s far exceeds that of these older lamps, ex. Mercury, Metal Halide, Xenon models and intensity remains broadly constant throughout its life providing a stable, repeatable light source. Some of the many fluorophores excited by the PE-300 Series are FITC, DAPI, Cy3, Auramine, TxRed, mCherry, TRITC, ChR, Hoechst, Cy5, Calcofluor, RFP to name a few.

The MT6300CW Series employs Meiji Techno’s all new ICOS™ (Infinity Corrected Optical System) making the study of mounted specimens fast and easy while delivering an excellent cost-to- performance ratio. The MT6300CW Series microscope are configured for Brightfield and Epi-flourescence but can also be outfitted with optional phase contrast, polarized light and darkfield components. System modularity makes purchase and operation

PE-300W/LEDMT is a LED fluorescence illumination kit, configured for fluorophores such as DAPI, FITC, TRITC & Cy5, instant on/off with the ability to optimize intensity & minimize sample damage via the simple desktop Control Pod with a manual control pod and power supply. (Included in MT6200CW & MT6200ECW & MT6300CW & MT6300ECW models)

The award-winning PE-300 Series is a range of LED Illumination Systems for Fluorescence Microscopy, Optogenetics, Electrophysiology and high-speed microscopy applications. It comprises 3 systems providing a solution that covers a range of everyday fluorescence microscopy; from the simple PE-300L/LEDTC or PE-300L/LEDMT (lite versions) through the classic PE-300W/LEDMT or PE-300W/LEDTC (white versions). The PE-300 Series offers:

   • High intensity at your microscope sample plane – view and image your samples brighter than ever
   • Adjustment of output in 1% steps on all systems – giving precise control whether imaging quickly or for a gentler approach to care for your samples.
   • Spectral coverage for all your everyday fluorophores: DAPI, CFP, Aqua, GFP, FITC, Tritc, TxRed, Cy5 and alike.

Features:
•Computer Aided Design Frame and Optics
•Ergonomically positioned controls
•Comfortable Siedentopf Viewing Heads
•Quintuple turret DIN nosepiece
•Six Position Fluorescence Module with three Chroma Fluorochromes included
•CHROMA - 19002 - AT-GFP/FITC - Basic Blue
•CHROMA - 19004 - AT-TRITC/Cy3 - Basic Green
•CHROMA - CHROMA - 3900 - AT-DAPI/Hoechst/AlexaFluor - Basic UV
•MA898 Empty filter cube available as an option to fit in the additional 3 empty filter cube spots for specialized Chroma filters
•Newly Designed Semi Apo Plan Fluorescence Objectives
•Brightfield, Darkfield, Phase Contrast, Polarized Light and Epi-Fluorescence modes
•LED Transmitted Koehler + CoolLed Epi Module
•LED products are more sustainable and energy efficient than conventional illuminators
•Mercury-free
•Energy Efficient: 80% less power
•Long lifetime (25,000 operating hours)
•No Bulb replacements
•Reduced risk of eye damage
•Quiet operation
•No special disposal regulations or issues
•Optional motorized stage and focus drive
•Optional Ergonomic Binocular or Trinocular Viewing Head available
very affordable for colleges, universities, researchers and clinics.

MT6300CW-HD Includes:
   • MT6300CW: Trinocular Epi-Flourescence /Brightfield Compound Microscope with Quintuple Nosepiece and PE-300W/LED MT CoolLED incident light source and LED transmitted illumination.
   • HD1000-LITE-M: The HD1000-LITE is a HDMI /USB2.0 camera technology from Meiji Techno! It is the most economical HDMI & USB 2.0 camera in the market. You can easily operate the HD1000-LITE camera by directly connecting it to a monitor with a HDMI port without a PC and directly save images into an on-board SD-4G card on the camera, or connect the camera directly to your PC as it has a standard USB 2.0 interface to utilize the full annotation/software function
   • MA151/35/03: C-mount adapter with 0.3X lens
   • MA879/05: CHROMA filter-AT-GFP/FITC longpass-19002 mounted in Meiji Filter cube, Exciter(EX) AT480/30x, Dichroic (BS)AT505DC, Emitter(EM)AT5151p (Factory Installed)
   • MA880/05: CHROMA filter-AT-TRITC/Cy3 Longpass-19004 mounted Meiji filter cube, Exciter (EX)AT540/25x, Dichroic (BS)AT565DC, Emitter(EM)575lp (Factory Installed)
   • MA881/05: CHROMA filter-AT-DAPI/Hoechst/AlexaFlour 350-3900 mounted in Meiji filter cube, Exciter (EX):AT375/28x, Dichroic (BS):AT415DC, Emitter (EM):AT460/50m (Factory Installed)
   • FLPWJ: D.C. Power Supply (This power supply is for the 100W Mercury lamp only)
   • MA860: ND25 Neutral Density filter, 29.8mm diameter
   • MT-RF47: UV Eye protection filter
   • PE-300W/LEDMT: LED fluorescence illumination kit, configured for fluorophores such as DAPI, FITC, TRITC & Cy5, adds greater control options to the platform, 3 channel control pod allows selection and control of excitation wavelength whether its to balance your FITC against your TRITC or to minimize bleaching by exciting only the markers that you are working. Supported by popular imaging software giving integrated control with your imaging set up time after time. An additional benefit of the PE-300W/LEDMT is that stains can be viewed either individually or in combination, without filter cube changes. This makes it ideal for use with multi-band filter sets as the screening process can be simplified when fewer filter cubes are used. Independent control for the three LED channels means that the user can control the level of excitation of each fluorescent stain independently on a multi-stained samples, potentially removing the need for single band filter sets altogether. Instant on/off with the ability to optimize intensity and minimize sample damage via the simple desktop Control Pod with a manual control pod and power supply.
(Included in MT6200CW & MT6200ECW & MT6300CW & MT6300ECW models)
          PE-300W/LEDMT features:
          - Remote control via USB or TTL trigger
          - Three LEDs
          - Simple to fit, simple to use: no alignment, a once only adjustment
          - Instant on/off - no shutters required, no warm up or cool down
          - Stable and repeatable - reliable and precise results
          - Precise intensity control in 1% steps (0-100%): no ND filters required
   • MA816: Trinocular head-Siedentopf type, I.P. adjustment 53mm to 75mm, graduated diopter on left eyetube (30.0mm I.D. eyetube).  Inclined at 30 degrees, Inverted image


   • MA817 (x 2): SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm


   • MA844: Plan Semi Apo Objective F10X, N.A.0.40, W.D.1.0 mm, F.N.24
   • MA845: Plan Semi Apo Objective F20X, N.A. O.65, W.D. 0.7 mm, F.N.24
   • MA846: Plan Semi Apo Objective F40X, N.A. 0.82, W.D. 0.15 mm, F.N.24  
   • MA848: Plan Semi Apo Objective F100X oil, N.A. 1.25, W.D.0.2mm, F.N.24

 


   • MA700: Immersion oil
   • MA910: Abbe condenser, N.A.1.25 with iris diaphragm and dove tail mount


   • MA856/05: LB100 Blue Clear filter, 44.0mm diameter, unmounted
   • MA918R: Ceramic coated flat-top stage, 190mm x 149mm, with 80mm x 52mm X-Y movement, with right hand drop down coaxial controls


   • MA598: Attachable finger assembly for MA918R and MA918L
   • MA326: 6V 30W Halogen lamp (Factory Installed)
   • MA327: 3 Amp Fuse for Halogen illuminator
   • MA809/10: Removable AC Electric cord with plug (115V)
   • MA906 (x 2): Rubber Eyeshield for MA817 SWH10X eyepiece (Factory installed)
   • MA714: Dust Cover for MT6000 Series
   • Manual: MT6000 Meiji Techno Instruction Manual
   • Warranty:Limited Lifetime Warranty Card

HD1000-LITE-M Includes:
   • HD1000-LITE - Camera HDMI 1/3 “ CMOS CHIP
   • HDMI to HDMI Cable 3 foot long cable
   • USB 2.0 to USB2.0 cable
   • Full SD CARD-H4SD card(4G)
   • Power Supply 12V AC./DC adapter
   • USB 2.0 Mouse
   • Measurement Software with Annotation Feature Installation Disc
   • 11.6" Monitor

Package Information:
   • 5lbs
   • 12 x 10 x 4 inches


NEW: BUILT-IN MOUSE CONTROL CAMERA
The significant innovation of the HD1000-LITE is making the software implant inside the camera. This forward thinking feature frees users from cumbersome computers and annoying buttons. You can control the camera by only a mouse directly.

01

Videos of the camera in action with our microscopes:
Brief overview with the compare feature
With Darkfield microscopy.

 

PERFECT COLOR REPRODUCTION
Meiji Techno's HD technology offers true-to-life reproduction on image color. What you see on the monitor is what you get from the microscope eyepiece. No compressed date transmission, resulting in scientific-grade images.

02

HDMI+USB 2.0+SD OUTPUT
Multiple output options are available for this powerful HDMI camera. HDMI 1080P, USB 2.0, or SD memory card can be used individually or all three SIMULTANEOUSLY.

03

DUAL FPGA PROCESSORS
With an innovative Dual FPGA processor architecture design, FPGA1 for image quality processing and FPGA2 for image output control, you get a high-speed preview without sacrificing image quality. It is the most powerful camera you deserve to have.

05

SMART PRESENTATION
Camera parameters such as exposure time, white balance, and gain are designed by default to operate automatically. Automatic optimum configuration is expected to be done in 0.015 seconds, and you'll find that the camera is easily managed from the start.

06

ADVANCED PARAMETER SETTING
For users with specific requirements, the camera is designed with parameter setting buttons that enable manual adjustment of white balance, gain, saturation, Gamma and screen freeze.

07

PC TO TV
Images are displayable on PCs and HDMI-installed TVs. All parameters can be controlled by the computer to adjust them to actual situations. This is advantageous in teaching and meeting applications.

08

On-board Video Saving
The SD card can save not only still images, but also dynamic images in 720P color definition, such that motion trails are recorded in fast speed and intact form.

09

LOW LIGHT SENSITIVITY
Thanks to its highly sensitive sensor, the HD1000-LITE is capable of capturing low-light images rapidly. In darkfield imaging and even fluorescence, it will automatically increase the sensitivity, presenting low light images with clarity in high-speed preview mode.

10

Model
Type
Version
Mega Pixels
Resolution
Frame Rate (FPS)
Sensor
C" Mount

HD1500T

HDMI/USB 2.0 Color 2-6MP 3264 x 1840 Static
1920 x 1080 Dynamic
60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500TM
with 11.8" HDMI montior

HDMI/USB 2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET

HDMI/USB 2.0 Color 2-6MP 3264 x 1840 Static
1920 x 1080 Dynamic
60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET-M
with 11.8" HDMI montior

HDMI/USB 2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET-AF
(Autofocus/Continuous 1-shot)

HDMI/USB2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET-M-AF
(Autofocus/Continuous 1-shot/with 11.8" monitor)

HDMI/USB2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1000-LITE

HDMI/USB 2.0 Color 5MP

2592 x 1944

15fps by HDMI
15fps by USB 2.0

1/2.5" CMOS

0.3X

HD1000-LITE-M
with 11.8" HDMI montior

HDMI/USB 2.0 Color 5MP

2592 x 1944

15fps by HDMI
15fps by USB 2.0

1/2.5" CMOS

0.3X

HD1600T

USB 3.0 Color 16MP 4608 x 3456

25fps by USB 3.0

1/2.33" CMOS

0.3X

SS500-MC

Wifi Color 5MP 2912 x 1640 60fps by Wifi 1/2.3" CMOS 0.3X

WF300
Eyepiece Camera

Wifi Color 8MP 3200 x 2400 60fps by USB 2.0
30fps by Wifi
1/2.8" CMOS 20-43mm
Eyepiece Mount

WF200

Wifi Color 5MP 2592 x 1944 40fps by USB 2.0
15fps by Wifi
1/2.8" CMOS 0.3X

WF100
Document Scanner

Wifi Color 5MP 2592 x 1944 30fps by Wifi - -

X-1000U

USB 2.0 Color 5MP 2592 x 1911 10fps by USB 2.0 1/2.8" CMOS 0.3X

MIS-PL-DV24

USB 2.0 Color 2MP 1600 x 1200 30fps by USB 2.0 1/2" CMOS 0.5X

DK-LITE-B

USB 2.0 Color 1.5MP 1440 x 1080 10fps by USB 2.0 1/2.5" CMOS 0.5X

DK1000CB

USB 2.0 Color 2MP 1600 x 1200 15fps by USB 2.0 1/2" CMOS 0.5X

DK1000M

USB 2.0 Monochrome 1.3MP 1280 x 1024 30fps by USB 2.0 1/2" CMOS 0.5X

DK3000C

USB 2.0 Color 3.1MP 2048 x 1536 12fps by USB 2.0 1/2" CMOS 0.5X

DK5000C

USB 2.0 Color 5MP 2592 x 1944 5fps by USB 2.0 1/2.5" CMOS 0.7X

HD2000C

USB 2.0 Color 2MP 1920 x 1080 60fps by USB 2.0 1/3" CMOS 0.3X

ST1000C

USB 3.0 Color 5MP 2592 x 1944 60fps by USB 3.0 1/2.5" CMOS 0.5X

 

Frequently Asked Questions

Q: Start the software and get the camera recognized, but the preview is all black.
A: Check whether the anti-dust cap on the C-mount is removed. If already removed and attach the camera to the microscop, check whether the lighting path toggle switch to the camera. Then try to extend the exposure time and gain to get brighter images.

Q: The imaging scene from the eyepiece is in focus but the live images from the camera are still out of focus.
A: This is because the camera and the eyepiece are in different focal planes. Can consider to use adjustable adapter to connect camera to the microscope trinocular, and the adjust the adapter to make the live image in focus.

Q: There are some shadows on the image and the shadows always stay in the same position even when the sample is moved.
A: Possible reasons:
1. The anti-dust film on the camera C-mount is not removed. Remove the anti-dust film
2. Check to see if there is any dirt on the objective. Clean the objective.
3. Some dust on the surface of the camera IR filter. Clean the camera optical port.

Q: Camera frame rate is extremely slow.
A: Possible reasons:
1. Preview resolution is too high. Try lowering the resolution and check the change of the frame rate.
2. Exposure time is too long. If need exposure time longer than 200ms, try to use higher gain to get brighter images.
3. Computer issue. Computer is very old or the motherboard chipset is Intel 8 Series/C220 series.

Q: Start the software and get the error message: can not recognize the camera or No camera.
A: Possible reasons:
1. The camera USB cable is not well connected. Reconnect the camera again.
2. Check whether the camera is connect to the USB port on the front of the mainframe. If so, then connect it to the USB port on the back of the mainframe. The USB ports on the front of the mainframe are the extended ports from the motherboard which can not provide stable voltage and current for cameras.
3. The camera itself needs extra power supply but does not switch on the power. TrueChrome is required to switch on power, attach to the PC and then restart the software. TCC-6.1ICE is required to plug in power to be recognized by PC.
4. The camera driver is not installed or failed to install. Go to the "Device Manager" > "Imaging Devices" and check whether the camera is listed WITH YELLOW FLAG. Then re-install the driver again. If still fail to install to driver, please contact camera technical support for help.

Q: Image Field of View (FOV) is much smaller than the scene can be seen from the eyepieces.
A: Possible reasons:
The camera sensor size is not 1 inch. It needs reduce lens to get bigger FOV.
Low resolution is used to preview. Set full resolutionion.
The reduce lens does not match the camera sensor size.

Q: When push “Capture” button, sometimes the saved images are quite blurry.
A: It could be because some slight vibration happens on the camera during capturing the images.

Q: Security shield on ISCapture shortcut.
A: Some anti-virus or firewall softwaree installed in the PCs will identify the DLL files from ISCapture as virus and automatically isolate or delete the ISCapture software files. If have the warning message to delete or isolate the DLL files during the ISCapture installation, please ignore the warning message or set the ISCapture as trusted software. Otherwise, the ISCapture can not be used normally.

Q: Newer version software con not recognize the old cameras.
A: Currently, all the newer version software ISCapture is compatible with the previous version cameras EXCEPT TCA Series.

Q: After doing the measurement on the live images, the captured image is without any measurement data.
A: To save the live measurement on captured images, check the “Combined Measurements” checkbox in the File Save tab and then capture images. While doing the still image measurements, only click the Save or Save As on the right hand side shortcut to save the data on the images.

Q: The live images and the captures images color is quite different from the one we can see from the eyepieces.
A: Because of the different lighting source, White Balance is needed to correct the image color.

Q: How to do quick White Balance?
A: White Balance while attached to camera to stereo microscope: Use a white paper to replace the sample. Click on “White Balance” to correct the image color > Remove the white paper and put back the sample.
White Balance while attach the camera to the biological microscope: Move the sample slide to the blank area. Click on “White Balance” and move back the sample.

Q: After install ISCapture and firstly start the software, but get the error “The program can’t start because MSVCP100.dll is missing from your computer. Try reinstalling the program to fix this problem.”


A; This is because the operating system lack of some Visual C++ 32bit library files which the ISCapture needs to call them. Without these files, the software can not be started normally. Install the patch VCredist_x86.exe (can be found in the CD that comes with the camera or go to http://www.microsoft.com/en-us/download/details.aspx?id=5555

Q: Start the ISCapture but get the error “Unable to execute file C:\Program Files\ISCapture\ISCapture.exe CreateProcess failed; code 740.

 


A: Completely remove the ISC Capture, reboot the PC and then right click on ISCapture installer (ISCapture Setup.exe) and select “Run as Administrator” to install the ISCapture. When you first start the software right click on the ISC icon and select “Run as Administrator” to start it.

Q:When start ISCapture, get error message “Cannot find the USB Key!”

A: The software is encrypted. Specific USB key is needed to attach to the computer port first.

Q:After capturing several images, it takes more and more time to save a frame image. Sometimes it is even up to more than 30 seconds, and then finally the software hang or crash.
A: If the image save directory is the network driver, during uploading the files to network driver, it will significantly increase the COP usage. When the CUP usage is up to 100%, the software will hang or crash. Recommend to change the file save directory to the computer hard disk.

Q: Whether can share the calibration files on different PCs?
A: If using the ISCapture earlier version than V4.0: Go to the folder “Application Data/ISCapture” in system disk, find the file “calibrationTable.ini” and copy it to another PC under the same directory. (The “Application Data” folder is a hidden folder, you might need to make the system invisible visible first.)
If it is ISCapture V4.0 or later, go to the Parameter tab and click “Backup” to backup the parameter settings and copy them to another PC to restore them.

Q:After install the ISCapture and every time I run the software i get the error:

A: This is because some program in the user’s PC is using the library file ‘libiomp5md.dll’which will conflict with the ISCapture. So far as we know, the software GoPro Studio will conflict with ISCapture. To solve this issue, please try to remove the libiomp5md.dll from the C:\Windows\System32 folder while using the ISCapture.

Q: Shortcut keys for ISCapture to capture still images and videos:
A: With ISCapture V3.6.6 or later, running the ISCapture first, Press F9 key on the keyboard to capture images. Press F10 to start the video recording. If in manual recording mode, press F11 to stop the recording.

Q: On preview images, lots of horizontal lines appear.


A: This is because of the lighting frequency. Extend exposure time or turn off the filament lamp or fluorescent lamp in the environment to solve this issue.

Q:Recording issue when connected to the HD1500T/HD1000 Series to the monitor and recorded video directly to the SD card? If so, do you know what the capacity of the SD card the user used during recording the videos?
A:When recording videos to the SD card, the camera only supports the SD card with format SDHC. It can not work with the SD card format SDXC. And max. capacity of the SDHC format SD card is 32GB which means the SD card with capacity >= 64GB, is format SDXC.
If already use SDHC format SD card, please help to confirm the information below:
1). Whether the customer used the SD card came with the HD1500T/HD1000 camera?
2). If not, what exactly the model of the SD card the customer used? Maybe some picture of the SD card.

If got the issue while connect the camera to the computer, I need to confirm below information:
1). The software always stop recording AUTOMATICALLY after 5-10 minutes?
2). Whether the software or the computer freeze if MANUALLY stop the recording?

Product Information:
   • Manufactured: 100% MADE IN JAPAN / 100% MADE IN UK (CoolLED)
   • Warranty: LIMITED LIFETIME WARRANTY
   • Customer Support: 1-(800) 832-0060 (U.S.A Based)

MT6300CW Package Information:
   • Weight: 39 lbs (17.6 kg)
   • Box Size: 16 x 14 x 21 inches
   • Footprint: 263mm (D) x 176mm (W)
   • Trinocular head type: 390 mm(D) x 465mm(H) x 210mm(W) (12.64kg)( 46.0 lbs.)

HD1000-LITE-M Package Information:
   • 5lbs
   • 12 x 10 x 4 inches

Details

Epi-Fluorescent with LED:
Intensity from a conventional lamp decreases through its life, which means that illumination varies dramatically over time. The lifetime of LED’s far exceeds that of these older lamps, ex. Mercury, Metal Halide, Xenon models and intensity remains broadly constant throughout its life providing a stable, repeatable light source. Some of the many fluorophores excited by the PE-300 Series are FITC, DAPI, Cy3, Auramine, TxRed, mCherry, TRITC, ChR, Hoechst, Cy5, Calcofluor, RFP to name a few.

Note: First decide on the Microscope model that fits your requirement, Binocular or Trinocular, or Ergo-Binocular or Ergo-Trinocular model. Secondly decide on the proper Meiji Techno CoolLED illumination unit for your application. Simple to Choose: No alignment or adjustment needed once installed, already configured for your everyday fluorophores such as DAPI, FITC, TRITC &Cy5 and affordable through your lab consumables budget.

The PE-300W/LEDMT white is a compact and simple to use LED illumination unit. It provides a broad spectrum of illumination, covering the excitation bands of common fluorescent stains. Operation is by a remote manual control pod with instant on/off and intensity control from 0-100%. Remote control is available via USB or TTL trigger.

The PE-300W/LEDMT white now delivers DOUBLE the intensity at the microscope sample plane. It allows adjustment of output in 1% steps, giving precise control. The broad spectrum covers everyday fluorophores: DAPI, CFP, Aqua, FITC, TRITC, TxRed, Cy5 and many more. Simple to Fit: Direct fit means the CoolLED unit just attaches straight onto the microscope’s epi-fluoresence port in seconds which is optimized for light output for your microscope. Simple to Use: Instant On/Off with the ability to optimize intensity and minimize sample damage via the simple desktop Control Pod, really simple to fit and use immediately with less down time for set-up.

DAPI can be excited at either 365nm or 400nm and microscopes typically have a filter set which allows one or other of these wavelengths to be transmitted. To accommodate this, the pE-300white can be specified in one of two waveband configurations to match with the user’s existing filter sets within the microscope.

A microscope which is populated with a number of single band (“SB”) filter sets will typically have DAPI excitation at 365nm and a microscope with multi-band (“MB”) filter(s) has excitation at 400nm. The user can specify the configuration which is appropriate for their microscope.

Power requirements
100-240V a.c. 50/60Hz, 2A

Power consumption
Standby Max 2W
2018-2019 Meiji Techno America MT6000 LED Series Fluorescent Microscopes
113
1 band (GYR) at 100% intensity Max 20W
2 bands (BLU & GYR) at 100% intensity Max 38W
White (all 3 bands) at 100% intensity 46W

The PE-300L/LEDMT is a simple white light LED illumination system that offers intense, broadspectrum LED illumination for imaging most common fluorescent stains.

The PE-300L/LEDMT Light Source can be fitted directly to the microscope or specified with a liquid light guide. The system is a mercury-free alternative that is safer, more controllable, and repeatable than conventional high-pressure gas discharge illuminators. Spectral coverage is from the UV (DAPI excitation) to the Red region (Cy5 excitation). The system is perfect for hospital and regular research laboratory environments and is affordable within consumables budgets. 

DAPI can be excited at either 365nm or 400nm and microscopes typically have a filter set which allows one or other of these wavelengths to be transmitted. To accommodate this, the pE-300lite can be specified in one of two waveband configurations to match with the user’s existing filter sets within the microscope.

A microscope which is populated with a number of single band (“SB”) filter sets will typically have DAPI excitation at 365nm and a microscope with multi-band (“MB”) filter(s) has excitation at 400nm. The user can specify the configuration which is appropriate for their microscope.

Power requirements
100-240V a.c. 50/60Hz, 1.4A
Power consumption
2W (standby)
46W (full white intensity)

Microscope with Epi-Fluorescence is an optical microscope that uses fluorescence and phosphorescence instead of, or in addition to, reflection and absorption to study properties of organic or inorganic substances. The “fluorescence microscope” refers to any microscope that uses fluorescence to generate an image, whether it is a more simple set up like an epifluorescence microscope, or a more complicated design such as a confocal microscope, which uses optical sectioning to get better resolution of the fluorescent image. Equipped with Chroma filters and a six position filter holder, there is a slot to add 3 more filter cubes and desired filters for your specific experiment or application.

The MT6200CL, MT6200CW & MT6300CL, MT6300CW Series employs Meiji Techno’s all new ICOS™ (Infinity Corrected Optical System) making the study of mounted specimens fast and easy while delivering an excellent cost-to-performance ratio. The MT6200CL, MT6200CW & MT6300CL, MT6300CW Series microscopes are configured for brightfield and epi-flourescence but can also be outfitted with optional phase contrast, polarized light and darkfield components. System modularity makes purchase and operation very affordable for colleges, universities, researchers and clinics. 2018-2019 Meiji Techno America MT6000 LED Series Fluorescent Microscopes 114

Features:
• Computer Aided Design Frame and Optics
• Ergonomically positioned controls
• Comfortable Siedentopf Viewing Heads
• Quintuple turret DIN nosepiece
• Six Position Fluorescence Module with three Chroma Fluorochromes included :
• CHROMA - 19002 - AT-GFP/FITC - Basic Blue
• CHROMA - 19004 - AT-TRITC/Cy3 - Basic Green
• CHROMA - 3900 - AT-DAPI/Hoechst/AlexaFlour - Basic UV
• MA898 Empty filter cube available as an option to fit in the additional 3 empty filter cube
spots for specialized Chroma filters
• Newly Designed Semi Apo Plan Fluorescence Objectives
• Brightfield, Darkfield, Phase Contrast, Polarized Light and Epi-Fluorescence modes
• Reduced risk of eye damage
• Quiet operation
• No special disposal regulations or issues
• Optional motorized stage and focus drive
• Optional Ergonomic Binocular or Trinocular Viewing Head available
• LED Transmitted Koehler + CoolLed Epi Module
• LED products are more sustainable and energy efficient than conventional illuminators
• Mercury-free
• Energy Efficient: 80% less power
• Long lifetime (25,000 operating hours)
• No Bulb replacements
• Works with everyday fluorophores/stains
• Affordable through lab consumables budget
• Broad spectrum - covers UV (DAPI) to Red region (Cy5)
• Specify for existing single and multi-band filter sets – no need to buy new filters
• Instant on/off - No shutters required, no warm up or cool down
• Stable & repeatable – reliable and consistent results
• Precise intensity control in 1% steps (0-100%) – no ND filters required
• Excellent uniformity over field of view – fixed and stable, no alignment necessary

Model
Head
Illumination
Eyepieces
Objectives
Stage
Condenser

MT6200CL

Binocular
Incident PE-300L/LEDMT CoolLED + Transmitted Koehler LED
 
SWH10x FN22
Semi Plan Apo F10x, F20x, F40x, F100x
Fixed flat-top left or right-handed controls
Abbe NA 1.25 with iris in dovetail mount

MT6200ECL

Ergonomic Binocular

MT6300CL

Trinocular

MT6300ECL

Ergonomic Trinocular

MT6200CW

Binocular Incident PE-300W/LEDMT CoolLED + Transmitted Koehler LED

MT6200ECW

Ergonomic Binocular

MT6300CW

Trinocular

MT6300ECW

Ergonomic Trinocular

VIEWING HEADS
Model MA815 is the Siedentopf-type binocular head and MA816 is the trinocular head for camera integration. Each head has the eyetubes inclined at 30 degrees with the left eyetube having graduated diopter settings. The interpupillary distance is adjustable between 53mm - 75mm. An 80/20 beamsplitter for the trinocular tube can be engaged for photo-microscopy; 100% to eyetubes or 80% to phototube & 20% to the eyetube. The optional MA957, Ergonomic Binocular Viewing Head, has the inclination adjustable from 10 to 50 degrees to fit users of different heights. The Ergonomic Trinocular model comes with the MA958, photo/video attachment with sliding 80/20 beam-splitter (Included in MT6300EH).

EYEPIECES
10X Super Widefield High Eyepoint eyepieces F.N.22 are standard, and 15X and 20X eyepieces are also available as an option. A Super Widefield High Eyepoint 10X focusable eyepiece that accepts 25mm reticules is also available.

OBJECTIVE CHANGER
Quintuple nosepiece provides effortless objective changes with smooth-operating, ball bearing mounted.

OBJECTIVES
Meiji Techno offers an all new assortment of Infinity Corrected Semi Apochromat objectives for Fluorescence Microscopy and U.Plan Objectives for Brightfield/Darkfield, Phase and Polarized work

STAGE
Ceramic coated flat top stage measures 191mm x 126mm with 100mm x 100mm x-y travel. Ergonomically positioned left or right-handed coaxial drop down controls. Available with motorized components.

CONDENSER
Abbe condenser NA 1.25 with iris in dovetail mount is included. Optional condenders include a Zernike Phase Contrast Condenser NA 1.25 with iris in dovetail mount and darkfield condenser with dovetail mount.

ILLUMINATION
A powerful LED lamp provides enhanced image quality and brightness for the observation of specimens. The standard Modular Six Position Epi-fluorescent illuminator employs a PE-300L/LEDMT LED fluorescence illumination Kit, configured for fluorophores such as DAPI,FITC,TRITC & Cy5, Instant on/off with the ability to optimize intensity and minimize sample damage via the simple desktop Control Pod with a manual control pod and power supply (Included in MT6200CL & MT6200ECL & MT6300CL & MT6300ECL models)

      •PE-300L/LEDMT: LED fluorescence illumination kit, configured for fluorophores such as DAPI, FITC , TRITC & Cy5, instant on/off with the ability to optimize intensity & minimize sample damage via the simple desktop Control Pod with a manual control pod and power supply. (Included in MT6200CL & MT6200ECL & MT6300CL & MT6300ECL models)

      •PE-300W/LEDMT: LED fluorescence illumination kit, configured for fluorophores such as DAPI, FITC, TRITC & Cy5, adds greater control options to the platform, 3 channel control pod allows selection and control of excitation wavelength whether its to balance your FITC against your TRITC or to minimize bleaching by exciting only the markers that you are working. Supported by popular imaging software giving integrated control with your imaging set up time after time. An additional benefit of the PE-300W/LEDMT is that stains can be viewed either individually or in combination, without filter cube changes. This makes it ideal for use with multi-band filter sets as the screening process can be simplified when fewer filter cubes are used. Independent control for the three LED channels means that the user can control the level of excitation of each fluorescent stain independently on a multi-stained samples, potentially removing the need for single band filter sets altogether. Instant on/off with the ability to optimize intensity and minimize sample damage via the simple desktop Control Pod with a manual control pod and power supply.
(Included in MT6200CW & MT6200ECW & MT6300CW & MT6300ECW models)

PHOTOMICROGRAPHY
Meiji Techno offers a broad range of digital video cameras which offers excellent sensitivity, high resolution and a wide dynamic range for the most demanding brightfield and darkfield microscopy applications including clinical pathology and cytology, life sciences and geology. Some models has included software, that can preview and capture still shots and live videos to a PC or Mac with USB port or HDMI connectivity.

Details

Components & Accessories

BASIC FLUORESCENCE FILTER SETS INCLUDED IN ALL MODELS:
   • MA879/05: CHROMA filter-AT-GFP/FITC longpass-19002 mounted in Meiji Filter cube, Exciter(EX) AT480/30x, Dichroic (BS)AT505DC, Emitter(EM)AT5151p (Factory Installed)
   • MA880/05: CHROMA filter-AT-TRITC/Cy3 Longpass-19004 mounted Meiji filter cube, Exciter (EX)AT540/25x, Dichroic (BS)AT565DC, Emitter(EM)575lp (Factory Installed)
   • MA881/05: CHROMA filter-AT-DAPI/Hoechst/AlexaFlour 350-3900 mounted in Meiji filter cube, Exciter (EX):AT375/28x, Dichroic (BS):AT415DC, Emitter (EM):AT460/50m (Factory Installed)

The Basic Blue and Basic Green filter sets are designed primarily for viewing the fluorescence of a single fluorochrome. Both filters sets contain long pass emission filters which cannot exclude the fluorescence of a second fluorochrome which also maybe excited. NOTE: Additional filter sets may be purchased through Chroma Technology Corporation. An additional MA898 (empty replacement filter cube) will need to be ordered for the new filters. 1-800- 824-7662 www.chroma.com sales@chroma.com

OPTIONAL COMPONENTS & ACCESSORIES BELOW

Viewing Heads:
   • MA815: Binocular head - Siedentopf type, I.P. adjustment 53mm to 75mm, graduated diopter on left eyetube (30.0 mm I.D. eyetube). Inclined at 30 degrees Inverted Image (Included in Model MT6300H)
   •MA816: Trinocular head - Siedentopf type, I.P. adjustment 53mm to 75mm, graduated diopter on left eyetube (30.0 mm I.D. eyetube). Inclined at 30 degrees Inverted Image (Included in Model MT6300H)
   • MA957: Ergonomic tilting binocular head - Adjustable vertically from 10 to 50 degrees (30.0 mm I.D. eyetube) Erect image (Included in Ergonomic Model MT6200EH & MT6300EH)

Photo/Video Attachment:
   • MA958: Photo / video attachment with sliding 80/20 beam-splitter. For use with video or digital cameras when MA957/05 ergonomic head is used (Included in Ergonomic Model MT6300EH)

Eyepieces:
   • MA817: SWH 10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm (each) (MA817 accepts optional 25mm diameter reticle) (included) (2 pieces)
   • MA818: SWH 15X Widefield high eyepoint eyepiece, Field No. 16.0, tube O.D. 30.0 mm (each) (19mm reticle mount)
   • MA819: SWH 20X Widefield high eyepoint eyepiece, Field No. 12.0, tube O.D. 30.0 mm (each) (19mm reticle mount)
   • MA859: SWH 10X-F Focusing eyepiece with reticle mount (without reticle), tube O.D. 30.0 mm (each) (25mm reticle mount)

Plan Semi Apochromat Objectives for Fluorescent Microscopy:
   • MA844: Plan Semi Apo Objective F10X, N.A. 0.40, W.D.1.0 mm, F.N. 24 (Included)
   • MA845: Plan Semi Apo Objective F20X, N.A. 0.65, W.D. 0.7 mm, F.N. 24 (Included)
   • MA846: Plan Semi Apo Objective F40X, N.A. 0.82, W.D. 0.15 mm, F.N. 24 (Included)
   • MA847: Plan Semi Apo Objective F40X oil, N.A. 0.85, W.D. 0.2 mm, F.N. 24, FL (Optional)
   • MA848: Plan Semi Apo Objective F100X, N.A. 1.25, W.D. 0.2 mm, F.N. 24, FL (Included)

Plan Apochromat Phase Objectives for Fluorescent Microscopy:
   • MA1012: Plan Apochromat Objective F4X, N.A. 0.13, W.D. 17.5 mm, F.N. 24
   • MA980: Plan Apochromat Objective F10X, N.A. 0.30, W.D. 8.6 mm, F.N. 24
   • MA981: Plan Apochromat Objective F20X, N.A. 0.65, W.D. 0.7 mm, F.N. 24
   • MA982: Plan Apochromat Objective F40X, N.A. 0.80, W.D. 0.2 mm, F.N. 24, FL
   • MA983: Plan Apochromat Objective F100X oil, N.A. 1.25, W.D. 0.2 mm, F.N. 24

Plan Semi Apochromat Objectives - Brightfield Objectives:
   • MA830: Plan Semi Apo Objective 2.5X, N.A. 0.07, W.D. 5.7mm, F.N. 24
   • MA831: Plan Semi Apo Objective 4X, N.A. 0.10, W.D. 17.8 mm, F.N. 24
   • MA832: Plan Semi Apo Objective 10X, N.A. 0.25, W.D. 10.7 mm, F.N .24
   • MA833: Plan Semi Apo Objective 20X, N.A. 0.40, W.D. 7.29 mm, F.N. 24
   • MA834: Plan Semi Apo Objective 40X, N.A. 0.65, W.D. 0.5 mm, F.N. 24
   • MA837: Plan Semi Apo Objective 100X oil, N.A.1.25, W.D. 0.23 mm, F.N. 24

Plan Semi Apochromat Objectives - Phase Objectives:
   • MA839: Plan Semi Apo Phase Objective 10X, N.A. 0.25, W.D. 10.7 mm, F.N. 24
   • MA840: Plan Semi Apo Phase Objective 20X, N.A. 0.40, W.D. 7.29 mm, F.N. 24
   • MA841: Plan Semi Apo Phase Objective 40X, N.A. 0.65, W.D. 0.5 mm, F.N. 24
   • MA842: Plan Semi Apo Plan Phase Objective 100X oil, N.A. 1.25, W.D. 0.23mm, F.N. 24

Zernike Phase Condenser:
   • MA913: Zernike Phase condenser with centerable phase annuli for 10X, 20X, 40X, 100X with brightfield position, dark-field stop for 40X objective, (Black-out position for epi-fluorescence on MT6000 Series only) with iris in dove tail mount (Included in Models MT5210L, MT5310L, MT5210H and MT5310H and Ergo models)

Other Zernike Components:
   • MA458/05: Centering Telescope, 30.0 mm O.D. (Included in Model MT5210L, MT5310L, MT5210H and Ergo models)
   • MA861/05: Green Interference filter (GIF), 44.0 mm diameter, unmounted (Included in MT5210L, MT5310L, MT5210H and MT5310H and Ergo models)

Darkfield Oil Immersion Objectives & Condenser System:
   • MA836: Plan Semi Apo Objective 50X, N.A. 0.87, oil with iris, W.D. 0.28, F.N. 24
   • MA838: Plan Semi Apo Objective 100X, N.A. 1.25, oil with iris, W.D. 0.23, F.N. 24
   • MA914: Darkfield condenser, N.A. 1.25, dove-tail mount (with ball bearing)

Filters for use with Transmitted Light:
   • MA858/05: ND 25 Neutral density filter, 44.0mm diameter, unmounted
   • MA856/05: LB100 Blue Clear filter 44.0mm diameter, unmounted
   • MA857/05: Green filter, clear, 44.0mm diameter, unmounted
   • MA861/05: Green Interference filter,(GIF) 44.0mm diameter, unmounted 
   • MA898: Empty filter cube for excitation filter set

Brightfield Condensers: 
   • MA910/10: Abbe condenser, N.A. 1.25, with centerable Phase annuli in slider for use with 20X and 40X Phase objectives, with iris diaphragm and dovetail mount
   • MA910/15: Abbe condenser, N.A. 1.25 with darkfield stop in slider for use with 20X and 40X brightfield objectives, with iris diaphragm and dovetail mount
   • MA911: Achromatic condenser, N.A. 1.25 with iris diaphragm and dovetail mount
   • MA976: Abbe condenser, N.A. 0.90 with swing out top lens, iris diaphragm and dovetail mount For use with low power scanning objective, MA830
   • MA1024: Aplanatic condenser, N.A. 1.40 with, iris diaphragm, an dovetail mount 790.00
For use with high magnification Apochromat objectives

Polarizer: 
   • MA915: Polarizer set for MT5000 Series microscopes

Stages
   • MA918R: Ceramic coated flat-top stage, 190mm x 149mm with 80mm x 52mm X-Y movement, and right hand drop-down coaxial controls
   • MA598: Attachable clinical finger assembly for MA918R and MA918L (Included)
   • MA676: Attachable clinical specimen holder for MA918R and MA918L (optional)

Eyepiece Micrometers (25mm diameter for the use with MA817 SWH 10x eyepiece)
   • MA523: Cross-line reticle, 25mm diameter
   • MA506: 10mm line divided into 100 units, 25mm diameter
   • MA509: 5mm line divided into 100 units, 25mm diameter
   • MA524: 10mm square divided into 400 parts, each square 0.5 mm, 25mm diameter
   • MA510: 10mm square divided into 100 parts, each square 1.0 mm, 25mm diameter
   • MA542: Cross-line reticle with 0.1mm graduations, 25mm diameter

Stage Micrometers
   • MA285: 1mm divided into 100 units, 0.01mm
   • MA286: 0.04” divided into 40 units, 0.001”
   • MA809/20: Removable AC Electric Cord with plug for 220v models (included in all 220v models)

Illuminators
   • PE300L/LEDMT: LED fluorescence illumination Kit, configured for fluorophores such as DAPI, FITC,TRITC & Cy5, Instant on/off with the ability to optimize intensity and minimize sample damage via the simple desktop Control Pod with a manual control pod and power supply ( Included in MT6200CL & MT6200ECL & MT6300CL & MT6300ECL models)
          PE-300L/LEDMT features:
          - Direct fit to the microscope in seconds
          - Broad spectrun - covers UV (DAPI) to Red region (Cy5)
          - No alignment, a once only adjustment
          - Instant on/off - no shutters required, no warm up or cool down
          - Stable and repeatable - reliable and precise results
          - Fine intensity control in 1% steps (0-100%) - no ND filters required
          - Excellent uniformity over field of view - fixed and stable, no alignment necessary
   • PE-300W/LEDMT: LED fluorescence illumination kit, configured for fluorophores such as DAPI fluorophores such as DAPI, FITC, TRITC & Cy5 , adds greater control options to the platform, 3 channel control pod allows selection and control of excitation wavelength whether it’s to balance your FITC against your TRITC or to minimize Bleaching by exciting only the markers you are working. Supported by popular imaging software giving integrated control with your imaging set up time after time. An additional benefit of the PE-300W/LEDMT is that stains can be viewed either individually or in combination, without filter cube changes. This makes it ideal for use with multi-band filter sets as the screening process can be simplified when fewer filter cubes are used. Independent control for the three LED channels means that the user can control the level of excitation of each Fluorescent stain independently on a multi-stained samples, potentially removing the need for single band filter sets altogether. Instant on/off with the ability to optimize intensity and minimize sample damage via the simple desktop Control Pod with a manual control pod and power supply (Included in MT6200CW & MT6200ECW & MT6300CW & MT6300ECW models)
          PE-300W/LEDMT features:
          - Remote control via USB or TTL trigger
          - Three LEDs
          - Simple to fit, simple to use: no alignment, a once only adjustment
          - Instant on/off - no shutters required, no warm up or cool down
          - Stable and repeatable - reliable and precise results
          - Precise intensity control in 1% steps (0-100%): no ND filters required

Replacement Bulbs & Fuses
   • MA809/10: Removable AC Electric cord with plug (included in all 115v models)
   • MA809/20: Removable AC Electric cord with plug for 220v models
   • BA005: HBO 100W Mercury lamp (2200 Lumens, Life expectancy 200 hours)

Power Cords
   • MA326: Spare bulb 6V 30W halogen lamp (Replacemnet bulb for transmitted light)
   • MA327: Spare 3A Fuse for Halogen illuminator

Carrying Case
   • MT-PEL: Pelican case with foam insert 21.5(L) X 16.5 (W) X 12.5 (D) for ML/MT/EM Models with portable pull out handle and wheels for protection againse vibration and shock

Miscellaneous
   • MA972: Centering target for Mercury bulb alignment (Similar to a stage micrometer but with concentric circles for aligning the image of the bulb arc)
   • MA996: Adapter to connect Prior Metal Arc Lamp to Meiji MT6000 - Prior Metal Halide power and light guide required
   • MA906: Eyeshield for MA817 SWH 10X eyepiece (each)
   • MA714: Dust cover for MT6000 (vinyl) (included)
    


Double click to read at full screen
Download Brochure (PDF)



Double click to read at full screen
Download Manual (PDF)




Double click to read at full screen
Download Manual (PDF)




Double click to read at full screen
Download Manual (PDF)


HD1000-LITE-M Quick Start Guide
Download Camera Driver (ZIP)
Download ISCapture Software (ZIP)


Download New MAC Software MosaicV2 - 9/17/2019
Download Older MAC ISListen Capture Software

Download ISListen MAC Installation Guide (PDF)


 


Double click to read at full screen
Download Manual (PDF)


 


Double click to read at full screen
Download Software Manual (PDF)


 


Double click to read at full screen
Download Menu Quick Guide (PDF)