MT7100L-HD1500MET-M/0.3 50X-500X LED Trino Brightfield Metallurgical Microscope with Incident Light Only and HD Camera Monitor (HD1500MET-M)

This configuration consists of the MT7100L and the HD1500MET-M Camera.

Meiji Techno's new upright Brightfield incident light metallurgical microscope is the new and cost-effective MT7000 Series Microscope. The MT7000 Series employs all new and improved optics. Meiji Techno's ICOS™ (Infinity Corrected Optical System) makes the observation and evaluation of metallurgical specimens fast and easy while delivering an excellent cost-to-performance ratio.

The MT7000 and MT7100 Series are versatile, modular, and ergonomic metallurgical systems.The newly designed Epi-Plan optics provide exceptionally crisp images, good color rendition and superior flat field of view. The MT7000 and MT7100 Series offer high magnification with incident light which allows users to view samples at high magnification. These systems are great for applications such as electroplating coatings, grain size, surface inclusions and defects.

The HD1500MET-M is our full featured 6 MP camera with a 1/3” CMOS chip.  A 0.3X C-mount adapter (MA151/35/03) is needed to attach to any standard Meiji Techno America Trinocular Microscope. The HD1500MET-M features a full HD (1080x1920) resolution, which provides high fidelity images with a refresh rate of 60fps- frames per second when connected via HDMI, so there is absolutely no lag in the live video feed when moving your specimen or part. Included with the 11.8” High Definition display is a mounting kit that allows the display to be mounted directly in front of the HD1500MET-M.

The 11.8” High Definition display is used with the provided USB 2.0 mouse; with this the user can access menus that provide all the features of the camera such as exposure, white balance, color control (red or blue), gamma, brightness, sharpness, saturation, denoise, color temperature. In addition, it allows the user to save images and videos directly on the full SD card due to the onboard operating system. You can flip the image horizontally, vertically, do a split screen where-in one side of the monitor is a live image and the other half is the captured image. You can also digitally increase/decrease the zoom if needed if your stereo system has reached its magnification potential, this will give you the added digital magnification needed. You can also superimpose a cross-line reticle directly on your live image, first click gives you a red line second click gives you a green line, and the third click omits the crossline. The live video and still shots can be saved directly on the removable full SD card for subsequent image capture. All this is achieved without the need for a PC. You may also connect directly to any monitor or TV with a HDMI port for a wider view if necessary.  All USB 2.0, HDMI, SD card, power supply is all supplied. You can also attach a wireless mouse if you choose to go wireless with a third party mouse.

NOTE:
• 6MP Still resolution 3264x1836
• 2MP Live video 1920x1080 60 fps (frames per second) via HDMI
• 2MP Live video 1920x1080 30 fps (frames per second) via USB2.0


made in japan


Locate a DealerGet a Quote


cerohs

Model
Head
Illumination
Eyepieces
Objectives
Stage

MT7000

Binocular
30W Vertical Koehler
 
SWH10x FN22
Plan Epi 5x, 10x, 20x, 50x
Fixed flat-top left or right-handed controls

MT700EH

Ergonomic Binocular

MT7100

Trinocular

MT7100EH

Ergonomic Trinocular

MT7000L

Binocular
LED Illumination

MT7000EL

Ergonomic Binocular

MT7100L

Trinocular

MT7100EL

Ergonomic Trinocular

MT7100L Includes:
   • MT7100L: Trinocular Compound Metallurgical Microscope with Vertical Koehler LED Incident (Reflected) light observation and Infinity Corrected Optical System
   • HD1500MET-M: The HD1500MET-M is our full featured 6 MP camera with a 1/3” CMOS chip.  A 0.3X C” mount adapter (MA151/35/03) is needed to attach it to any standard Meiji Techno America Trinocular Microscope.  The HD1500MET-M features a full HD (1080x1920) resolution, which provides high fidelity images with a refresh rate of 60fps- frames per second when connected via HDMI, so there is absolutely no lag in the live video feed when moving your specimen or part.  Included with the 11.8” High Definition display is a mounting kit that allows the display to be mounted directly in front of the HD1500MET-M.
   • MA151/35/03: C-mount adapter with 0.3X lens
   • MA816: Trinocular head-Siedentopf type, Interpupillary Diameter adjustment 53mm to 75mm, graduated diopter on left eyetube (30.0mm I.D.eyetube). Inclined at 30 degrees
head
   • MA817 (x 2): SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm

   • MA870: Plan Epi Objective 5X, N.A.0.10, W.D. 20.0 mm, F.N.24
   • MA871: Plan Epi Objective 10X, N.A. 0.25, W.D. 7.48 mm, F.N. 24
   • MA872: Plan Epi Objective 20X, N.A. 0.40, W.D. 5.20 mm, F.N. 24
   • MA873: Plan Epi Objective 50X, N.A. 0.75, W.D. 0.38 mm, F.N. 24

   • MA927/L: Vertical Koehler LED illuminator, with clear blue, N.D.50 neutral density filter and polarizing filter in metal mounts.  Auto voltage sensing AC adapter built into stand 100V-240V (Powered by transformer built into MT7000L Series stand)

   • MA475/05: Blue clear filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
   • MA774: N.D.50 neutral density filter, 19.5 mm diameter filter in metal mount, fits 25 mm filter slot
   • MA497: Polarizing filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
   • MA941: Ceramic coated flat-top stage, 191mm X 126 mm, 100mm X 100mm X-Y movement, with right hand drop-down coaxial controls

   • PKL/LED-I/BULB: 5W LED Bulb for LED illuminator(Factory Installed)
   • MA929: 0.5Amp Fuse for LED illuminator(Factory Installed)
   • MA809/20: Removable AC electric cord with plug for 115V Models
   • MA906 (x 2): Rubber Eyeshield for MA817 SWH10X eyepiece
   • MA711: Dust cover for all MT7000 Series microscope
   • Manual: Meiji Techno America MT7000 Manual
   • Warranty:Limited Lifetime Warranty Card

HD1500MET-M Includes:
   • HD1500MET-M Camera
   • 11.8in HDMI Monitor
   • HDMI Cable
   • USB Cable
   • 12V AC/DC Power adapter
   • SD Card
   • Retina Screen
   • Mouse
   • "L" Bracket Adapter for Monitor to Camera connectivity
   • Application Metrics Software ISCapture
   • Packing Box

MULTIFORM MEASUREMENT TOOLS 
The HD1500MET-M provides extremely powerful measurement functionality including: freehand lines, rectangles, polygons, circles, bicircles, angles, point-line distance and much more. In addition to the ability to measure point-line distance, angles, the length of curves and lines, the camera can measure the perimeter & area of enclosed features such as: rectangles, polygons, and circles. The unique calibration and magnification functions coupled with the ability to export the results to Excel or text files, make the measurements more convenient and simple.

01

 

MICRON LEVEL MEASUREMENT ACCURACY 
The HD1500MET-M is capable of delivering measurements with a resolution of 10 nanometers which provides an incredible metrology capability in the most demanding situations.

02

MEASUREMENT FOR VARIOUS APPLICATIONS
In addition µm, the HD1500MET-M also provides calibrations in mm and cm, which will meet various measurement requirements in different applications. And these results provide objective and reliable data to support quantitative analysis.

03

CONVENIENT MEASUREMENT DATA MANAGEMENT
Two measurement results exporting modes (Excel and text) make the measurement data management more convenient.

03

30FPS HIGH SPEED LIVE IMAGE
With 30fps data transfer at an uncompressed resolution of 1920X1080, sets a precedent. It is one of the fastest USB2.0 cameras in the world.

05

EXCELLENT CAPABILITY FOR FLUORESCENCE
Taking advantage of the ultra high signal to noise ratio sensor, the HD1500MET-M provides for up to 10 seconds exposure time and gets finest detailed images, even for low light fluorescence.

06

3D NOISE REDUCTION
Longer exposure times increase the image noise. But the integrated 3D noise reduction function keeps the image always clean and sharp.

06

1080P VIDEO RECORDING
Just click the button to start recording 1080P videos at 30fps. The recorded video files will be saved to the high speed SD card. It is also possible to play back the videos from the SD card directly.

06

SUPERB SMART CAMERA
It automatically analyzes the acquired images, optimizes the white balance, exposure time and saturation to present perfect images. Whatever, for bright field or dark field applications, ideal images can be captured, barely needing any parameter adjustments.

06

SIMPLE OPERATIONS
The embedded user interface is so simple that not even one mouse click is required to bring up the two simple menus. There are only two icons on the splash, one for capture, the for settings.

06

 

Model
Type
Version
Mega Pixels
Resolution
Frame Rate (FPS)
Sensor
C" Mount

HD1500T

HDMI/USB 2.0 Color 2-6MP 3264 x 1840 Static
1920 x 1080 Dynamic
60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500TM
with 11.8" HDMI montior

HDMI/USB 2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET

HDMI/USB 2.0 Color 2-6MP 3264 x 1840 Static
1920 x 1080 Dynamic
60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET-M
with 11.8" HDMI montior

HDMI/USB 2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET-AF
(Autofocus/Continuous 1-shot)

HDMI/USB2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1500MET-M-AF
(Autofocus/Continuous 1-shot/with 11.8" monitor)

HDMI/USB2.0 Color 2-6MP

3264 x 1840 Static
1920 x 1080 Dynamic

60fps by HDMI
30fps by USB 2.0
1/2.8" CMOS 0.3X

HD1000-LITE

HDMI/USB 2.0 Color 5MP

2592 x 1944

15fps by HDMI
15fps by USB 2.0

1/2.5" CMOS

0.3X

HD1000-LITE-M
with 11.8" HDMI montior

HDMI/USB 2.0 Color 5MP

2592 x 1944

15fps by HDMI
15fps by USB 2.0

1/2.5" CMOS

0.3X

HD1600T

USB 3.0 Color 16MP 4608 x 3456

25fps by USB 3.0

1/2.33" CMOS

0.3X

SS500-MC

Wifi Color 5MP 2912 x 1640 60fps by Wifi 1/2.3" CMOS 0.3X

WF300
Eyepiece Camera

Wifi Color 8MP 3200 x 2400 60fps by USB 2.0
30fps by Wifi
1/2.8" CMOS 20-43mm
Eyepiece Mount

WF200

Wifi Color 5MP 2592 x 1944 40fps by USB 2.0
15fps by Wifi
1/2.8" CMOS 0.3X

WF100
Document Scanner

Wifi Color 5MP 2592 x 1944 30fps by Wifi - -

X-1000U

USB 2.0 Color 5MP 2592 x 1911 10fps by USB 2.0 1/2.8" CMOS 0.3X

MIS-PL-DV24

USB 2.0 Color 2MP 1600 x 1200 30fps by USB 2.0 1/2" CMOS 0.5X

DK-LITE-B

USB 2.0 Color 1.5MP 1440 x 1080 10fps by USB 2.0 1/2.5" CMOS 0.5X

DK1000CB

USB 2.0 Color 2MP 1600 x 1200 15fps by USB 2.0 1/2" CMOS 0.5X

DK1000M

USB 2.0 Monochrome 1.3MP 1280 x 1024 30fps by USB 2.0 1/2" CMOS 0.5X

DK3000C

USB 2.0 Color 3.1MP 2048 x 1536 12fps by USB 2.0 1/2" CMOS 0.5X

DK5000C

USB 2.0 Color 5MP 2592 x 1944 5fps by USB 2.0 1/2.5" CMOS 0.7X

HD2000C

USB 2.0 Color 2MP 1920 x 1080 60fps by USB 2.0 1/3" CMOS 0.3X

ST1000C

USB 3.0 Color 5MP 2592 x 1944 60fps by USB 3.0 1/2.5" CMOS 0.5X

 

Frequently Asked Questions

Q: Start the software and get the camera recognized, but the preview is all black.
A: Check whether the anti-dust cap on the C-mount is removed. If already removed and attach the camera to the microscop, check whether the lighting path toggle switch to the camera. Then try to extend the exposure time and gain to get brighter images.

Q: The imaging scene from the eyepiece is in focus but the live images from the camera are still out of focus.
A: This is because the camera and the eyepiece are in different focal planes. Can consider to use adjustable adapter to connect camera to the microscope trinocular, and the adjust the adapter to make the live image in focus.

Q: There are some shadows on the image and the shadows always stay in the same position even when the sample is moved.
A: Possible reasons:
1. The anti-dust film on the camera C-mount is not removed. Remove the anti-dust film
2. Check to see if there is any dirt on the objective. Clean the objective.
3. Some dust on the surface of the camera IR filter. Clean the camera optical port.

Q: Camera frame rate is extremely slow.
A: Possible reasons:
1. Preview resolution is too high. Try lowering the resolution and check the change of the frame rate.
2. Exposure time is too long. If need exposure time longer than 200ms, try to use higher gain to get brighter images.
3. Computer issue. Computer is very old or the motherboard chipset is Intel 8 Series/C220 series.

Q: Start the software and get the error message: can not recognize the camera or No camera.
A: Possible reasons:
1. The camera USB cable is not well connected. Reconnect the camera again.
2. Check whether the camera is connect to the USB port on the front of the mainframe. If so, then connect it to the USB port on the back of the mainframe. The USB ports on the front of the mainframe are the extended ports from the motherboard which can not provide stable voltage and current for cameras.
3. The camera itself needs extra power supply but does not switch on the power. TrueChrome is required to switch on power, attach to the PC and then restart the software. TCC-6.1ICE is required to plug in power to be recognized by PC.
4. The camera driver is not installed or failed to install. Go to the "Device Manager" > "Imaging Devices" and check whether the camera is listed WITH YELLOW FLAG. Then re-install the driver again. If still fail to install to driver, please contact camera technical support for help.

Q: Image Field of View (FOV) is much smaller than the scene can be seen from the eyepieces.
A: Possible reasons:
The camera sensor size is not 1 inch. It needs reduce lens to get bigger FOV.
Low resolution is used to preview. Set full resolutionion.
The reduce lens does not match the camera sensor size.

Q: When push “Capture” button, sometimes the saved images are quite blurry.
A: It could be because some slight vibration happens on the camera during capturing the images.

Q: Security shield on ISCapture shortcut.
A: Some anti-virus or firewall softwaree installed in the PCs will identify the DLL files from ISCapture as virus and automatically isolate or delete the ISCapture software files. If have the warning message to delete or isolate the DLL files during the ISCapture installation, please ignore the warning message or set the ISCapture as trusted software. Otherwise, the ISCapture can not be used normally.

Q: Newer version software con not recognize the old cameras.
A: Currently, all the newer version software ISCapture is compatible with the previous version cameras EXCEPT TCA Series.

Q: After doing the measurement on the live images, the captured image is without any measurement data.
A: To save the live measurement on captured images, check the “Combined Measurements” checkbox in the File Save tab and then capture images. While doing the still image measurements, only click the Save or Save As on the right hand side shortcut to save the data on the images.

Q: The live images and the captures images color is quite different from the one we can see from the eyepieces.
A: Because of the different lighting source, White Balance is needed to correct the image color.

Q: How to do quick White Balance?
A: White Balance while attached to camera to stereo microscope: Use a white paper to replace the sample. Click on “White Balance” to correct the image color > Remove the white paper and put back the sample.
White Balance while attach the camera to the biological microscope: Move the sample slide to the blank area. Click on “White Balance” and move back the sample.

Q: After install ISCapture and firstly start the software, but get the error “The program can’t start because MSVCP100.dll is missing from your computer. Try reinstalling the program to fix this problem.”


A; This is because the operating system lack of some Visual C++ 32bit library files which the ISCapture needs to call them. Without these files, the software can not be started normally. Install the patch VCredist_x86.exe (can be found in the CD that comes with the camera or go to http://www.microsoft.com/en-us/download/details.aspx?id=5555

Q: Start the ISCapture but get the error “Unable to execute file C:\Program Files\ISCapture\ISCapture.exe CreateProcess failed; code 740.

 


A: Completely remove the ISC Capture, reboot the PC and then right click on ISCapture installer (ISCapture Setup.exe) and select “Run as Administrator” to install the ISCapture. When you first start the software right click on the ISC icon and select “Run as Administrator” to start it.

Q:When start ISCapture, get error message “Cannot find the USB Key!”

A: The software is encrypted. Specific USB key is needed to attach to the computer port first.

Q:After capturing several images, it takes more and more time to save a frame image. Sometimes it is even up to more than 30 seconds, and then finally the software hang or crash.
A: If the image save directory is the network driver, during uploading the files to network driver, it will significantly increase the COP usage. When the CUP usage is up to 100%, the software will hang or crash. Recommend to change the file save directory to the computer hard disk.

Q: Whether can share the calibration files on different PCs?
A: If using the ISCapture earlier version than V4.0: Go to the folder “Application Data/ISCapture” in system disk, find the file “calibrationTable.ini” and copy it to another PC under the same directory. (The “Application Data” folder is a hidden folder, you might need to make the system invisible visible first.)
If it is ISCapture V4.0 or later, go to the Parameter tab and click “Backup” to backup the parameter settings and copy them to another PC to restore them.

Q:After install the ISCapture and every time I run the software i get the error:

A: This is because some program in the user’s PC is using the library file ‘libiomp5md.dll’which will conflict with the ISCapture. So far as we know, the software GoPro Studio will conflict with ISCapture. To solve this issue, please try to remove the libiomp5md.dll from the C:\Windows\System32 folder while using the ISCapture.

Q: Shortcut keys for ISCapture to capture still images and videos:
A: With ISCapture V3.6.6 or later, running the ISCapture first, Press F9 key on the keyboard to capture images. Press F10 to start the video recording. If in manual recording mode, press F11 to stop the recording.

Q: On preview images, lots of horizontal lines appear.


A: This is because of the lighting frequency. Extend exposure time or turn off the filament lamp or fluorescent lamp in the environment to solve this issue.

Q:Recording issue when connected to the HD1500T/HD1000 Series to the monitor and recorded video directly to the SD card? If so, do you know what the capacity of the SD card the user used during recording the videos?
A:When recording videos to the SD card, the camera only supports the SD card with format SDHC. It can not work with the SD card format SDXC. And max. capacity of the SDHC format SD card is 32GB which means the SD card with capacity >= 64GB, is format SDXC.
If already use SDHC format SD card, please help to confirm the information below:
1). Whether the customer used the SD card came with the HD1500T/HD1000 camera?
2). If not, what exactly the model of the SD card the customer used? Maybe some picture of the SD card.

If got the issue while connect the camera to the computer, I need to confirm below information:
1). The software always stop recording AUTOMATICALLY after 5-10 minutes?
2). Whether the software or the computer freeze if MANUALLY stop the recording?

Product Information:
   • Manufactured: 100% MADE IN JAPAN
   • Warranty: LIMITED LIFETIME WARRANTY
   • Customer Support: 1-(800) 832-0060 (U.S.A Based)

MT7100L Package Information:
   • Weight: 30.8 lbs (13.6 kg)
   • Box Size: 16 x 14 x 21 inches
   • Footprint: 263mm (D) x 176mm (W)
   • Trinocular head type: 424.5 mm(D) x 526mm(H) x 210mm(W) (9.2kg)( 33.35 lbs)

HD1500MET-M Package Information:
   • 5lbs
   • 12 x 10 x 4 inches

Details

The MT7000 Series features include:

  • Computer Aided Design
  • Ergonomically positioned controls
  • Comfortable Siedentopf viewing head
  • 30W Vertical Koehler Illuminator with auto sensing power supply
  • Brightfield observation mode
  • Optional Ergonomic binocular viewing head available

VIEWING HEADS
Model MA815 is the Siedentopf-type binocular head and Model MA816 is the trinocular head for camera integration. Each head has the eyetubes inclined at 30° with the left eyetube having graduated diopter settings. The interpupillary distance is adjustable between 53mm - 75mm. An 80/20 beamsplitter for the trinocular tube can be engaged for photo work. The optional Ergonomic Viewing Head has the inclination adjustable from 10 to 50 degrees to fit any size user.

EYEPIECES
10X Super Widefield High Eyepoint eyepieces F.N.22 are standard, and 15X and 20X eyepieces are available as an option. A Super Widefield High Eyepoint 10X focusable eyepiece that accepts 25mm reticules is also available.

OBJECTIVE CHANGER
The smooth-operating, ball bearing mounted, quintuple nosepiece provides effortless objective changes.

OBJECTIVES
Meiji Techno offers an assortment of Plan Epi Infinity Corrected objectives for Brightfield work.

STAGE
Ceramic coated left or right-handed, flat top stage measures 191mm x 126mm with x-y travel: 100mm(X) x 100mm(Y). Ergonomically positioned coaxial drop down controls. 

CONDENSER
Strain free Abbe 1.25 NA Condenser with iris diaphragm in dovetail mount.

ILLUMINATION
Powerful LED illumination provides enhanced image quality and brightness for the observation of metallurgical specimens.

PHOTOMICROGRAPHY
Meiji Techno offers a broad range of digital video cameras which offers excellent sensitivity, high resolution and a wide dynamic range for the most demanding brightfield and darkfield microscopy applications including clinical pathology and cytology, life sciences and geology. Some models has included software, that can preview and capture still shots and live videos to a PC or Mac with USB port or HDMI connectivity.

Details

Model
Head
Illumination
Eyepieces
Objectives
Stage

MT7000

Binocular
30W Vertical Koehler
 
SWH10x FN22
Plan Epi 5x, 10x, 20x, 50x
Fixed flat-top left or right-handed controls

MT700EH

Ergonomic Binocular

MT7100

Trinocular

MT7100EH

Ergonomic Trinocular

MT7000L

Binocular
LED Illumination

MT7000EL

Ergonomic Binocular

MT7100L

Trinocular

MT7100EL

Ergonomic Trinocular

Components & Accessories

Included:
   • MT7100L: Trinocular Compound Metallurgical Microscope with Vertical Koehler LED Incident (Reflected) light observation and Infinity Corrected Optical System
   • MA816: Trinocular head-Siedentopf type, Interpupillary Diameter adjustment 53mm to 75mm, graduated diopter on left eyetube (30.0mm I.D.eyetube). Inclined at 30 degrees
   • MA817 (x 2): SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
   • MA870: Plan Epi Objective 5X, N.A.0.10, W.D. 20.0 mm, F.N.24
   • MA871: Plan Epi Objective 10X, N.A. 0.25, W.D. 7.48 mm, F.N. 24
   • MA872: Plan Epi Objective 20X, N.A. 0.40, W.D. 5.20 mm, F.N. 24
   • MA873: Plan Epi Objective 50X, N.A. 0.75, W.D. 0.38 mm, F.N. 24
   • MA927/L: Vertical Koehler LED illuminator, with clear blue, N.D.50 neutral density filter and polarizing filter in metal mounts.  Auto voltage sensing AC adapter built into stand 100V-240V (Powered by transformer built into MT7000L Series stand)
   • MA475/05: Blue clear filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
   • MA774: N.D.50 neutral density filter, 19.5 mm diameter filter in metal mount, fits 25 mm filter slot
   • MA497: Polarizing filter, 19.5mm diameter filter in metal mount, fits 25mm filter slot
   • MA941: Ceramic coated flat-top stage, 191mm X 126 mm, 100mm X 100mm X-Y movement, with right hand drop-down coaxial controls
   • PKL/LED-I/BULB: 5W LED Bulb for LED illuminator(Factory Installed)
   • MA929: 0.5Amp Fuse for LED illuminator(Factory Installed)
   • MA809/20: Removable AC electric cord with plug for 115V Models
   • MA906 (x 2): Rubber Eyeshield for MA817 SWH10X eyepiece
   • HD1500MET-M: The HD1500MET-M is our full featured 6 MP camera with a 1/3” CMOS chip.  A 0.3X C” mount adapter (MA151/35/03) is needed to attach it to any standard Meiji Techno America Trinocular Microscope.  The HD1500MET-M features a full HD (1080x1920) resolution, which provides high fidelity images with a refresh rate of 60fps- frames per second when connected via HDMI, so there is absolutely no lag in the live video feed when moving your specimen or part.  Included with the 11.8” High Definition display is a mounting kit that allows the display to be mounted directly in front of the HD1500MET-M.
   • MA151/35/03: C-mount adapter with 0.3X lens
   • MA711: Dust cover for all MT7000 Series microscope
   • Manual: Meiji Techno America MT7000 Manual

OPTIONAL COMPONENTS & ACCESSORIES BELOW

Viewing Heads:
   • MA815: Binocular head-Siedentopf type, Interpupillary Diameter adjustment 53mm to 75mm, graduated diopter on left eyetube (30.0mm I.D.eyetube). Inclined at 30 degrees
   • MA957: Ergonomic tilting binocular head - Adjustable vertically from 10 to 50 degrees (30.0 mm I.D. eyetube) Erect image (Included in MT7000EH, MT7100EH, MT7000EL and MT7100EL models)
   • MA959: Trinocular head - Siedentopf type, erect image with sliding 0/100 beamsplitter, inclined at 30 degrees, I.P. adjustment 53mm to 75mm, graduated diopter on left eyetube

Photo/Video Attachment :
   • MA958: Photo/video attachment with sliding 80/20 beam-splitter. For use with video or digital cameras when MA957 ergonomic head is used (Included in Model MT9550)

Eyepieces:
   • MA818: SWH 15X Widefield high eyepoint eyepiece, Field No. 16.0, tube O.D. 30.0 mm (each) (19mm reticle mount)
   • MA819: SWH 20X Widefield high eyepoint eyepiece, Field No. 12.0, tube O.D. 30.0 mm (each) (19mm reticle mount)
   • MA859: SWH 10X-F Focusing eyepiece with reticle mount (without reticle), tube O.D. 30.0 mm (each) (MA859 accepts optional 25mm diameter reticle)

Brightfield Plan Epi Objectives :
   • MA874: Plan Epi Objective 100X, N.A. 0.90, W.D. 0.37mm, F.N. 24

Brightfield LWD (Long Working Distance) Plan Epi Objectives :
   • MA920: LWD Plan Epi Objective 20X, N.A. 0.40, W.D. 11.0 mm, F.N. 24
   • MA921: LWD Plan Epi Objective 50X, N.A. 0.55, W.D. 7.5 mm, F.N. 24

Eyepiece Micrometer (25mm diameter for use with MA817 or MA859 eyepieces):
   • MA523: Eyepiece micrometer, cross-line reticle, 25mm diameter
   • MA506: Eyepiece micrometer, 10mm line divided into 100 units, 25mm diameter
   • MA509: Eyepiece micrometer, 5mm line divided into 100 units, 25mm diameter
   • MA510: Eyepiece micrometer, 10mm square divided into 100 parts, each square 1.0 mm, 25mm diameter
   • MA542: Eyepiece micrometer, cross-line reticle with 0.1mm graduations, 25mm diameter
   • MA738: Eyepiece micrometer, for grain sizing in steel

Eyepiece Micrometer (19mm diameter for use with MA818 or MA819 eyepieces):
   • MA279: Eyepiece micrometer, cross-line reticle, 19mm diameter
   • MA280: Eyepiece micrometer, 10mm line divided into 100 units, 19mm diameter
   • MA281: Eyepiece micrometer, 5mm line divided into 100 units, 19mm diameter
   • MA283: Eyepiece micrometer, 10mm square divided into 100 parts, each square 1.0 mm, 19mm diameter
   • MA539: Eyepiece micrometer, cross-line reticle with 0.1mm graduations, 19mm diameter

Stage Mircometers:
   • MA292: Metal stage micrometer, 1mm divided into 100 units, 0.01mm

Replacement Bulbs and Fuses:
   • PKL/LED-I/BULB: Spare fuse 3A for halogen Illuminator for MT7000 and MT7100
   • MA929: Spare fuse 0.5A for LED illuminator for MT7000 and MT7100


Double click to read at full screen
Download Brochure (PDF)



Double click to read at full screen
Download Manual (PDF)


**UPDATE ON HD1500MET & HD1500MET-M SOFTWARE 2/14/2019**


 


Double click to read at full screen
Download Software Update Instructions (PDF)
Download update.bin

Download MAC Software CaptureV2.1.3 - 3/16/2020
Download Older MAC ISListen Capture Software

Download ISListen MAC Installation Guide (PDF)


Download Camera Driver (ZIP)
Download TCapture Software (ZIP)


 


Double click to read at full screen
Download Software Manual (PDF)


 


Double click to read at full screen
Download Menu Quick Guide (PDF)


 


Double click to read at full screen
Download Calibrate Guide (PDF)


 


Double click to read at full screen
Download FAQ Sheet (PDF)


 


Double click to read at full screen
Download TCapture Software Manual (PDF)


 


Double click to read at full screen
Download HD1500MET Calibration Metric Measurement Instruction (PDF)