BAS-20SP 20MM Straight Drop Down Post for FA-3 or BAS-2 Stands

The BAS-20SP is a 20mm staright drop down post that is 4" in length. The BAS-20SP is compatible with FA-3 and BAS-2 stands which are used in CZ, EM, Short Unimac series.


NOTE: Additional items are needed to create a full microscope system. The following components are normally ordered: 
• Stereo Microscope Body (Zoom, Turret or Fixed) 
• Eyepieces (Requires 2 of identical magnification) 
• Stand (Pole stands, rigid arm stands, boom stands, heavy duty boom stands, wide surface stands or articulated arm stands) 
• Illumination Source (Fiber optic halogen, fiber optic LED, fluorescent ring or LED illumination) 
• Auxiliary Lens (Optional)



Locate a DealerGet a Quote

BAS-20SP Info:

20mm straight drop down post for FA-3 or BAS-2 stands 4" in length

Product Information:
   • Manufactured: 100% MADE IN U.S.A
   • Warranty: LIMITED LIFETIME WARRANTY
   • Customer Support: 1-(800) 832-0060 (U.S.A Based)

Package Information:
   • Weight: TBA
   • Box Size: TBA

Details

BAS-2 Features

   • BAS-2 is a heavy duty dual ball bearing arm industrial-type boom stand comes with a 32mm diameter drop down mounting post to perfectly complement our EMZ (Zoom), EMT (Turret), EMF (Fixed) Series Stereo Microscope with the proper focus block
   • BAS-2 uses linear ball bearings to support the horizontal arm, allowing it to glide over the work surface with none of the binding inherent in other boom stands 
   • 635mm (25”) vertical pole (Included)
   • 457.2mm (18”) horizontal pole (Included)
   • Minimal space requirement and greatest possible amount stability for EM Series stereo system up to 30lbs
   • No loss of stability even at its furthest travel
   • The BAS-2 can swing out of the way easily, clearing the workstation for other tasks
   • Vertical column is used to compensate for taller specimen heights to accommodate the working distances of different microscope bodies
   • Anti-rotation is stabilized by a locking pin on the vertical post
   • Safety Collar for vertical and horizontal stability
   • BAS-2 is equipped by a 80lb base 
   • Ergonomic flexibility, chemical resistant paint finish and corrosion resistant stainless steel columns make this boom stand an excellent choice in labs and production facilities
   • High density rubber feet for vibration stability
   • 100% MADE IN U.S.A

FA-3 Features

   • Articulating Stand with table Clamp for Examination of Large Working Area
   • 37", 939mm Reaching-out Length
   • 16", 406mm High Stainless Steel Pillar
   • 16 mm diameter bonder arm mounting pin (5/8”)
   • Locking handles keep the Articulated stand in position
   • Triple –Joint Articulating Design for Flexibility
   • Accepts FS tilting coarse focusing holder with 84.2 mm round diameter opening(Optional)
   • Accepts FSC tilting coarse and fine focusing holder with 84.2 mm round diameter opening (Optional)
   • Accepts OS-SP20MM – 20mm drop down post for use with focus blocks with a 20mm mounting hole (optional)

Details

Replacement Bulbs Listed by Part Number

NOTE: The size of these images will vary and some images have been re-sized to fit this page. Do not rely on the size of these images to determine which bulb you need.
NOTE: Incident light shines down from above; transmitted light shines up through the specimen from below.

Photo of group one bulbs.

 

MA111 MA260/05 MA261/SL-10 MA263/05 MA263/10 MA264/05 MA275/05

 

Part Number Description Application
MA111 12V 10W Incident light:ST-3, SKT-1B, SKT-2B, SKT-3B, GS2000
Incident & transmitted light: SKT-BT, SKT-2BT, SKT-3BT
Transmitted light: STC-3
MA260/05 6V 20W Halogen For MA260, MA264H, and MA264EX illuminators
MA261/SL-10 115V 20W
For "B" Stand and MA261/35 (TM200 Series illuminator)
MA263/05
115V 30W
For MA263 illuminators
MA263/10 220/240V 30W For MA263 illuminators
MA264/05 6.5V 2.75A For MA264 illuminators
MA275/05 12V 50W For ML5000 Series 50W models; ML7500, ML8500 All MT7500, MT8500 series


Photo of group one bulbs.

MA305/05  MA309/05 MA326 MA350/10 MA350/20 MA361/10 MA362/10

 

Part Number Description Application
MA305/05 8W Ring Fluorescent For MA305/100, MA305/200 ring fluorescent illuminators 
MA309/05 4W Tube Fluorescent For MA309 fluorescent box illuminators for GEM stand 
MA326 6V 30W Halogen (G4 base type) 
For ML2000 and ML5000 Series 30W models; all VT Series Models, IM7100, IM7200, ML2000, ML7000, ML8000, ML9000, TC5100, TC5200, TC5300, TC5400, TC5500, TC5600
All MT Series 30W models; all RZT & RZDT Stands
MA350/10
115V 30W
For GEM stand transmitted light
MA350/20 220/240V 30W For GEM stand transmitted light
MA361/10* 110V 20W Half-silvered bulb for TM400 Series 20W models (DISCONTINUED)
MA361/20* 220/240V 20W Half-silvered bulb for TM400 Series 20W models
MA362/10* 115V 30W Half-silvered bulb for TM400 Series 30W models (DISCONTINUED)
MA362/20* 220/240V 30W Half-silvered bulb for TM400 Series 30W models(DISCONTINUED)


Photo of group one bulbs.

MA560 MA561 MA570 FL180/70 FL150/70 MA357 MA358 MA590

 

Part Number Description Application
MA560 6V 1.2A Tungsten  Incident light: AB, ABZ, PB Stands
All BM/BMK Series models 
MA561 6V 1.2A Tungsten 

Transmitted light: AB, ABZ, PB Stands

Note: MA560 and MA561 may appear to be identical, but they are not interchangeable.

MA570 6V 10W Halogen 
Incident & transmitted light: ABE, ABH, ABZH, PBH Stands
FL150/70
21V 150W Halogen 
For Fiber Optic Light sources: All FT190 and FL150 Series
FL180/70 21V 150W Halogen  For FL180, FL181 & FL182 fiber optic illuminators
MA357 8V 12W Tungsten  Frosted - Fits Meiji Techno MT5500 Series Microscopes
MA358 8V 12W Tungsten  Clear - Fits Meiji Techno MT5500 Series Microscopes
MA590 110V 15W Tungsten Frosted - Fits Meiji Techno PBM Series Stands





DC Arc Lamps

Part Number Description Application
BA005 HBO 100W Mercury DC Arc Lamp TC5000 Series & MT6000 Series Equipped with Epi-Fluorescence Lamphouses
BA013 XBO 75W Xenon DC Arc Lamp  
BA014 XBO 100W Xenon DC Arc Lamp   


BA005 Information:

Brand: Ushio
Technology: Short-Arc Mercury
Useful Life Hours: 200
Lumen Output: 2200
Actual Wattage: 100
Voltage: 20
Base Type: SFa7.5+SFa9
Length (Inch): 3.54
Diameter (Inch): .394
Manufacturers Notes: The HBO 100W BA005 is a Mercury Arc 20V 100 W Lamp with a SFa7.5-2 base

This product is also a direct replacement for the following items:

  • 100W OSRAM HBO MICROSCOPE
  • 4050300507095
  • ALB UPC LER38445
  • ALB UPC: LER38445
  • ALB UPC:LER38445
  • AMERICAN OPTICAL 2087 BULB
  • DENTSPLY ULTRA CURE 100
  • EFOS ULTRA CURE 100
  • EFOS ULTRA CURE 100 BULB
  • HANOVIA HGH100W2 BULB
  • HBO 100W/2
  • HBO 100W/2 BULBS
  • HBO 100W/2 LIGHT BULB
  • HBO 100W/2 MERCURY LAMP
  • HBO 100W/2 OSRAM BULB
  • HBO 100W/2 OSRAM BULBS
  • HBO.100W.2
  • HBO100W/2
  • HBO100W/2 BULB
  • HBO100W/2 LAMP
  • HBO100W/L2
  • HBO100W2
  • JENA HBO 101/2 BULB
  • LD CAULK ULTRA CURE 100
  • LEICA 2087
  • LEICA 2087 BULB LAMP
  • LEICA 2087-001 BULB
  • LEICA 3040-0380 BULB
  • LEICA 500-138 BULB
  • LEICA 500138
  • LEICA DMRBE BULB
  • LEITZ 2087 BULB
  • LEITZ 2087-001 BULB
  • LEITZ 3040-0380 BULB
  • LEITZ 500-138
  • LEITZ 500-138 BULB LAMP
  • LEITZ DMRBE BULB LAMP
  • LER38445
  • LITE SOURCE LS-97 BULB
  • M5000-133
  • MICROSTAR IV MICROSCOPE
  • MICROVISION 804-137-001
  • MITEY LITE AMERICAN OPT
  • NARVA HBO 101/2 BULB
  • NIKON 1996G7 BULB
  • NIKON 235915 BULB
  • NIKON 5554-0102 BULB
  • NIKON 78589 BULB
  • NIKON DS-EPI-FL2 BULB
  • NIKON EPI FL BULB LAMP
  • NIKON LABOPHOT-2 MAIN
  • NIKON PHOTOLAB II BULB
  • OLYMPUS 8-B192 BULB
  • OLYMPUS 8229 BULB
  • OLYMPUS 8B192
  • OLYMPUS BH RFL BULB
  • OLYMPUS BH2-RFC BULB
  • OLYMPUS BH2-RFL BULB
  • OLYMPUS BX40F BULB
  • OLYMPUS IMTZ-RFL BULB
  • OM100W2L2
  • OM100WL2
  • OPTI QUIP 1500 BULB
  • OPTI QUIP BA-005 BULB
  • ORC AHD-100 BULB LAMP
  • OSRAM 1 X HBO 100 W/2
  • OSRAM 69217
  • OSRAM 69217-0
  • OSRAM 692170
  • OSRAM BULBS HBO 100W/2
  • OSRAM HB0100 W/2
  • OSRAM HBO 100 W/2
  • OSRAM HBO 100W/2
  • OSRAM HBO100W/2
  • OSRAM LAMP HBO 100 W/2
  • OSRAM LAMP HBO100W/2
  • OSRAM REPLACEMENT HBO100W2
  • OSRAM SYLVANIA 69217 BULB
  • OSRAM SYLVANIA HBO100W/2
  • PHILIPS CS100W/2 BULB
  • PLASMARC 100-5052 BULB
  • QL-0102/05
  • REICHERT M5000/133 BULB
  • SFA7,5-2 OSRAM
  • SYLVANIA 69217
  • SYLVANIA HBO 100 W/2
  • SYLVANIA HBO 100W/2
  • UPC 4050300507095
  • UPC LER38445
  • UPC: 4050300507095
  • UPC: LER38445
  • UPC:4050300507095
  • UPC:LER38445
  • VAN BRAUGHT HSA 100 BULB
  • WETZLAR 2087 BULB LAMP
  • WETZLAR 2087-001 BULB
  • WETZLAR 3040-0380 BULB
  • WETZLAR 500-138 BULB
  • WETZLAR DMRBE BULB
  • WILD 2087 BULB LAMP
  • WILD 2087-001 BULB
  • WILD 3040-0380 BULB
  • WILD 500-138 BULB
  • WILD DMRBE BULB
  • XENON L 117 BULB LAMP
  • XENON LM/100-2 BULB
  • ZEISS 1007-975 BULB
  • ZEISS 2800-18-4060D
  • ZEISS 38-00-18-4050
  • ZEISS 38-00-18-4060
  • ZEISS 38-00-18-4060D
  • ZEISS 38-02-13 BULB
  • ZEISS 38-16-13 BULB
  • ZEISS 38-16-16 BULB
  • ZEISS 3800-18-4050
  • ZEISS 3800-18-4060
  • ZEISS 3800184060
  • ZEISS 381613
  • ZEISS 9108491003
  • ZEISS AXIOSCOPE BULB LAMP

 

*Discontinued - subject to stock on hand
Click HERE for more Bulb info.

Light bulbs in microscope illuminators need to be replaced periodically. The bulbs on this page are most commonly used in Meiji Techno illumination systems. If you own a Meiji microscope and need a replacement, you should be able to purchase it at your local Meiji Dealer. Some older models or specialized microscopes may use bulbs that are not listed here. If you cannot find the correct bulb, please contact our technical support staff to assist you. Click HERE for information on Lamp Safety, Handling and Disposal.

Tips on extending bulb life

Bulbs have a rough life in a microscope: burning in an enclosed area for hours on end with a finite lifetime, the effects of too much heat and not enough ventilation, DC current from the dimmer circuit slowly thinning the metal of the filament. And with bulbs nowadays being manufactured more and more cheaply, the cumulative effect is not good for bulb longevity.

If the bulb is halogen or DC Arc Lamp type, DO NOT TOUCH THE GLASS with your bare hands when installing bulbs. Use the plastic bag it comes in to install the bulb. DO NOT jar or bump or run your scope in an environment that has excessive vibration. Turn your scope off if you do not need it on. Some bulbs have a rated life of only 100 - 200 hours so if you use your scope full time, be prepared to use bulbs.

Halogen bulbs in microscopes and fiber optic light sources can also have problems if the socket is worn out; i.e. the connection cannot sink enough heat away from the bulb and/or the electrical connection is weak. If your scope is an old workhorse who's starting to eat bulbs, check the bulb socket out for poor contact and discoloration of the contact. The bi-pin type bulb should push stiffly into the socket. If not, or if it wobbles around excessively, the socket is too old and needs replacement.

Components & Accessories

BAS Stand Series and Accessories
• 
BAS-1: Ball bearing stand with dual horizontal arms, 13" x 13" x 1.5" base,  25" vertical post, safety clamp, 32mm straight mounting post
• BAS-32SP: Replacement 32mm straight mounting post for BAS-1 (For use with RZ Series)
• BAS-38SP: Replacement 38mm (1.5") diameter, straight drop post with 5/8" mounting pin 
• BAS-32TP: Replacement tilting 32mm mounting post with 5/8" mounting pin
• BAS-2: Ball bearing stand with dual horizontal arms, adjustable from 5.5" to 18", 13" x 13" x 1.5" base, 25" vertical post, safety clamp and 20mm straight mounting post for MS-51/05 or MS-53/05 holder (Note: Socket Head cap screw for base: 1/2" x 2" 13TP)
• BAS-3: Ball bearing stand with dual horizontal arms, 13" x 13" x 1.5" base, 25" vertical post, safety clamp for MS-52/05 or MS-54/05 holder
 BAS-20SP: 20mm straight drop down post for FA-3 or BAS-2 stand 4" in length 



Double click to read at full screen
Download Brochure (PDF)


 


Double click to read at full screen
Download Manual (PDF)