ML6530 Halogen Trinocular Asbestos PCM Microscope [DISCONTINUED]

DISCONTINUED

DISCONTINUED ON 6/17/2019

The ML6530 is replaced with the ML6530L.


PCM (Phase Contrast) Microscopes for Asbestos fiber counting applications. Meiji manufactures these microscopes pursuant to NIOSH 7400 and OSHA ID 160 Reference methods. Built in Koehler illuminator with 6V 30W Halogen lamp and variable intensity control. Equipped with Phase contrast objectives, GIF filter, Walton & Beckett reticle and a centering telescope.
Made In Japan


Locate a DealerGet a Quote

Includes:
   • ML6530: Trinocular head with beam-splitter PCM (Phase Contrast) Microscopes for Asbestos fiber counting applications.  Meiji manufactures these microscopes pursuant to NIOSH 7400 and OSHA ID 160 Reference methods. Built in Koehler illuminator with 6V 30W Halogen lamp and variable intensity control. Equipped with Phase contrast objectives, GIF filter, Walton & Beckett reticle and a centering telescope
   • MA603: Inclined Trinocular head, 30° inclination, rotatable through 360°, dual graduated diopter eyetubes with interpupillary adjustments of 52mm to 72mm. A sliding beam splitter directs 100%of the light to the eyepieces or 80% to the camera and 20% to the eyepieces
   • MA489: DIN HWF 12.5X eyepiece, FN 15mm (ea) 
   • MA488W: DIN Focusing HWF 12.5X focusing eyepiece with Walton & Beckett reticle (Factory installed)
   • Objective Changer: Smooth operating , ball bearing mounted ergonomic, forward facing quadruple nosepiece (Factory Installed)
   • MA613: 10X/0.25 SM Semi Planachromat objective, W.D. 6.23mm
   • MA698: BF S. Plan Achromat Phase objective 40XS/N.A. 0.65
   • MA458: Centering Telescope
   • Stage: Mechanical X-Y stage with attached finger assembly and drop down post, attached stage is 120mm x 140mm rectangular mechanical stage with movements of 75mm X and 40mm Y and is graduated with Vernier readings to 0.1mm, equipped with low positioned drop down coaxial controls. (Factory Installed)
   • Focusing Adjustment: Coaxial coarse and fine focusing controls with graduation reading 2 microns power division.  Incorporates tension adjustment and safety Auto-focus stage stop lever
   • MA461/10: Achromatic Condenser N.A. 1.25 with iris diaphragm, filter tray and centerable 40X phase annulus in sliding mount
   • MA759: G.I.F. (Green Interference filter 546nm, 29.8mm diameter)
   • MA285: Stage micrometer, 1mm divided into 100 units  (Each division = 0.01mm)
   • MA326: Halogen bulb 6V 30W, replacement (Factory installed)
   • MA327: Fuse 3A, replacement (Factory installed)
   • MA712: Dust cover for ML6500 Series
   • Manual: Meiji Techno America ML6500 Manual
   • Warranty: Limited Lifetime Warranty Card 

   • Product Information:
   • Manufactured: 100% MADE IN JAPAN
   • Warranty: LIMITED LIFETIME WARRANTY
   • Customer Support: 1-(800) 832-0060 (U.S.A Based)

   • Package Information:
   • Weight: 28.0 lbs (7.7 kg)
   • Box Size: 22 x 16 x 14 inches
   • Footprint: 254mm (D) x 203mm (W)
   • Monocular head type: 255 mm(D) x 395 mm (H) x 195mm(W) 28.0 lbs. (7.7 kg)
   • Binocular head type: 255 mm(D) x 395 mm (H) x 195mm(W) 28.0 lbs. (7.7 kg)
   • Trinocular head type: 255 mm(D) x 440 mm (H) x 195mm(W) 30 lbs. (8.27 kg)

Model
Head
Illumination
Eyepieces
Objectives
Stage
Condenser

ML6510
(DISCONTINUED)

Monocular
Koehler Illuminator 6V 30W halogen with variable intensity control
HW12.5-F DIN Focusing eyepiece with Walton & Beckett reticle
SM Plan DIN brightfield 10X and BF S.Plan Achromatic positive phase contrast objective 40XS NA.0.65
Mechanical X-Y stage with attached finger assembly
Achromatic condenser NA 1.25 with iris filter tray and 40X positive phase annulus in sliding mount GIF (Green Interference Filter) 546nm, 29.8mm diameter

ML6520
(DISCONTINUED)

Binocular
HWF12.5X and HW10X-F DIN Focusing eyepiece with Walton & Beckett reticle

ML6530
(DISCONTINUED)

Trinocular

Details

The ML6500 Series features include:

  • DIN standard eyepieces HWF 12.5X and DIN HWF 12.5X-F focusing eyepieces with Walton & Beckett reticle (Type G-22 with 3:1 aspect ratio)
  • Mechanical X-Y stage with attached finger assembly
  • Achromatic condenser N.A. 1.25 with iris, filter tray and 40X positive Phase annulus in sliding mount
  • Coaxial coarse and fine focus adjustment with graduation, reading 2 microns per division with tension adjustment and safety auto focus stop
  • Built-in Koehler illuminator with 6V 30W halogen lamp & variable intensity control
  • GIF ( Green interference Filter) 546nm, 29.8 diameter
  • Centering Telescope
  • Stage micrometer 1mm divided into 100 units (each division= 0.01 mm)

PCM (Phase Contrast Microscopy):
Methodology for PCM Analysis - NIOSH 7400 & OSHA ID 160

Phase contrast microscopy is the method that is primarily used for estimating asbestos concentrations of airborne fibers. This method is quick and can be performed on-site for a rapid determination of concentrations of asbestos fibers in the air. Phase contrast microscopy does not positively differentiate between asbestos and other fibers. Positive identification of asbestos fiber must be performed using PLM (Polarized Light Microscopy) or Electron Microscopy (Method 7402)

Phase contrast microscopy, which was discovered by F. Zernike in 1932, is used to help the microscopist who has to observe sample preparations which give low contrast objects. The method enables the phase differences in a specimen to be converted to amplitude differences to give an image of good contrast. It requires the use of phase plate in the objective back focal plane and a phase ring in the condenser system and is usually used with a particular form of illumination.

Required Microscope Equipment: ML6500, MT6500 & MT6800
Series Positive phase contrast microscope with 10X Brightfield and 40X phase objective, GIF (Green Interference Filter), Walton & Beckett Reticle Type-22G, and stage micrometer with 0.01mm divisions.

Required Test Slide:
The HSE/NPL Mark II Phase Shift Test Slide Checks or standardizes the visual detection limits of the phase contrast microscope. The HSE/NPL Test Slide consist of conventional glass microscope slide with seven sets of parallel line pairs of decreasing widths. The microscope must clearly resolve line pairs 1-3. Line pairs 4-5 must be at least partially visible. Line pairs 6-7 must be invisible. A microscope which fails to meet these requirements is either too low or high in resolution and cannot be used for asbestos identification. Meiji Techno does not sell this slide. In day to day operations it should be remembered that after checking the system for test slide visibility the microscope will need to be correctly adjusted for viewing the membrane filter deposit; this should only require a slight refocusing of the field iris image.

Components & Accessories

Included:
   • ML6530: Trinocular head with beam-splitter PCM (Phase Contrast) Microscopes for Asbestos fiber counting applications.  Meiji manufactures these microscopes pursuant to NIOSH 7400 and OSHA ID 160 Reference methods. Built in Koehler illuminator with 6V 30W Halogen lamp and variable intensity control. Equipped with Phase contrast objectives, GIF filter, Walton & Beckett reticle and a centering telescope
   • MA603: Inclined Trinocular head, 30° inclination, rotatable through 360°, dual graduated diopter eyetubes with interpupillary adjustments of 52mm to 72mm. A sliding beam splitter directs 100%of the light to the eyepieces or 80% to the camera and 20% to the eyepieces
   • MA489: DIN HWF 12.5X eyepiece, FN 15mm (ea) 
   • MA488W: DIN Focusing HWF 12.5X focusing eyepiece with Walton & Beckett reticle (Factory installed)
   • MA254: Walton & Beckett reticle, 19mm diameter, 3:1 aspect ratio (Installed in MA413W)
   • Objective Changer: Smooth operating , ball bearing mounted ergonomic, forward facing quadruple nosepiece (Factory Installed)
   • MA613: 10X/0.25 SM Semi Planachromat objective, W.D. 6.23mm
   • MA698: BF S. Plan Achromat Phase objective 40XS/N.A. 0.65
   • MA458: Centering Telescope
   • Stage: Mechanical X-Y stage with attached finger assembly and drop down post, attached stage is 120mm x 140mm rectangular mechanical stage with movements of 75mm X and 40mm Y and is graduated with Vernier readings to 0.1mm, equipped with low positioned drop down coaxial controls. (Factory Installed)
   • Focusing Adjustment: Coaxial coarse and fine focusing controls with graduation reading 2 microns power division.  Incorporates tension adjustment and safety Auto-focus stage stop lever
   • MA461/10: Achromatic Condenser N.A. 1.25 with iris diaphragm, filter tray and centerable 40X phase annulus in sliding mount
   • MA759: G.I.F. (Green Interference filter 546nm, 29.8mm diameter)
   • MA285: Stage micrometer, 1mm divided into 100 units  (Each division = 0.01mm)
   • MA326: Halogen bulb 6V 30W, replacement (Factory installed)
   • MA327: Fuse 3A, replacement (Factory installed)
   • MA712: Dust cover for ML6500 Series
   • Manual: Meiji Techno America ML6500 Manual

OPTIONAL COMPONENTS & ACCESSORIES BELOW

Viewing Heads:
   • MA403: Inclined monocular head (Included in ML6510)
   • MA602: Inclined binocular head (Included in ML6520)

Eyepieces:
   • MA406: DIN HWF 10X eyepiece, F.N. 15mm (each)
   • MA413W: DIN focusing HWF 10X eyepiece with Walton and Beckett reticle (Factory Installed)

Brightfield Objectives:
   • MA614: 20X/0.40 SM Semi Planachromat objective, spring loaded, W.D. 3.13mm

Phase Condenser & GIF:
   • MA461/05: Achromatic condenser N.A. 1.25 with iris diaphragm, filter tray and non-centerable 40X phase annulus in sliding mount

Bulbs and Fuses:
   • MA326: Halogen bulb 6V 30W, replacement 
   • MA327: Fuse 3Amp, replacement


Double click to read at full screen
Download Brochure (PDF)



Double click to read at full screen
Download Manual (PDF)