SU-50D + HD1500MET-M LED Macro Zoom System (Includes HD1500MET-M)
MS-50D Info:
Short Unimac Macrozoom Lens 0.7X-4.5X with C-mount adapter with detent, working distance 94mm
PK/SP-1 Info:
The PK/SP-1 Pole Stand features include:
• PK Stand is Meiji Techno’s Low Profile Wide Ergonomic Plain which requires external illumination
• PK Stand is designed for the zoom (EMZ Series), and turret (EMT Series), fixed (EMF Series) stereo bodies Pillar diameter is 20mm, height is 11” (280 mm)
• Auto-Voltage Sensing Power supply (100V to 240V)
• MA551-A 5” extension pillar for the threaded vertical post is also available if needed to accommodate taller specimens
• ESD Safe, Chemical Resistant Finish
• Cast Aluminum Alloy Construction
• Compact Footprint Design: Length:330mm, Width: 300mm, Height: 255mm
• Stable rubber feet and locking pin for head stability
• 100% MADE IN JAPAN
• Limited Lifetime Warranty
NOTE: The PK stand in this system does not have a focus holder as it is replaced by the MS-51/05 focusing holder.
MS-51/05 Info:
Coarse focus block that fits 20mm mounting post of stands
MA551 Info:
4" Extension Pillar Aluminum with threads for P/PB/PBH/PKL/PLS stands.
MTI164-164 Info:
Mitutoyo Digimatic Indicator for X – Y axis movement: Range 50mm (2") (Fits into MA728 and MA729 port) (2 Required)
MA728 Info:
50mm x 50mm X – Y measuring stage to take digital micrometers
MA951D/30 Info:
The MA951D/30 model is carefully constructed by starting with an alluminum alloy that is precision machined. This unit has a 44mm opening and is specifically designed to fit onto zoom and fxed optics commonly used for machine vision and automated imaging applications. An auto voltage sensing 100 – 240 VAC power supply is included.
Key Specifications:
• 44mm inner diameter
• 30 individual LEDs
• Daylight color temperature
• Auto Voltage Sensing Power Supply
• 3 banks
• Standard Working Distance
• Remote Control not Available
HD1500MET-M Includes:
• HD1500MET-M Camera
• 11.8in HDMI Monitor
• HDMI Cable
• USB Cable
• 12V AC/DC Power adapter
• SD Card
• Retina Screen
• Mouse
• "L" Bracket Adapter for Monitor to Camera connectivity
• Application Metrics Software ISCapture
• Packing Box
MULTIFORM MEASUREMENT TOOLS
The HD1500MET-M provides extremely powerful measurement functionality including: freehand lines, rectangles, polygons, circles, bicircles, angles, point-line distance and much more. In addition to the ability to measure point-line distance, angles, the length of curves and lines, the camera can measure the perimeter & area of enclosed features such as: rectangles, polygons, and circles. The unique calibration and magnification functions coupled with the ability to export the results to Excel or text files, make the measurements more convenient and simple.
MICRON LEVEL MEASUREMENT ACCURACY
The HD1500MET-M is capable of delivering measurements with a resolution of 10 nanometers which provides an incredible metrology capability in the most demanding situations.
MEASUREMENT FOR VARIOUS APPLICATIONS
In addition µm, the HD1500MET-M also provides calibrations in mm and cm, which will meet various measurement requirements in different applications. And these results provide objective and reliable data to support quantitative analysis.
CONVENIENT MEASUREMENT DATA MANAGEMENT
Two measurement results exporting modes (Excel and text) make the measurement data management more convenient.
30FPS HIGH SPEED LIVE IMAGE
With 30fps data transfer at an uncompressed resolution of 1920X1080, sets a precedent. It is one of the fastest USB2.0 cameras in the world.
EXCELLENT CAPABILITY FOR FLUORESCENCE
Taking advantage of the ultra high signal to noise ratio sensor, the HD1500MET-M provides for up to 10 seconds exposure time and gets finest detailed images, even for low light fluorescence.
3D NOISE REDUCTION
Longer exposure times increase the image noise. But the integrated 3D noise reduction function keeps the image always clean and sharp.
1080P VIDEO RECORDING
Just click the button to start recording 1080P videos at 30fps. The recorded video files will be saved to the high speed SD card. It is also possible to play back the videos from the SD card directly.
SUPERB SMART CAMERA
It automatically analyzes the acquired images, optimizes the white balance, exposure time and saturation to present perfect images. Whatever, for bright field or dark field applications, ideal images can be captured, barely needing any parameter adjustments.
SIMPLE OPERATIONS
The embedded user interface is so simple that not even one mouse click is required to bring up the two simple menus. There are only two icons on the splash, one for capture, the for settings.
Model
|
Type
|
Version
|
Mega Pixels
|
Resolution
|
Frame Rate (FPS)
|
Sensor
|
C" Mount
|
HD1500T |
HDMI/USB 2.0 | Color | 2-6MP | 3264 x 1840 Static 1920 x 1080 Dynamic |
60fps by HDMI 30fps by USB 2.0 |
1/2.8" CMOS | 0.3X |
HD1500TM |
HDMI/USB 2.0 | Color | 2-6MP |
3264 x 1840 Static |
60fps by HDMI 30fps by USB 2.0 |
1/2.8" CMOS | 0.3X |
HD1500MET |
HDMI/USB 2.0 | Color | 2-6MP | 3264 x 1840 Static 1920 x 1080 Dynamic |
60fps by HDMI 30fps by USB 2.0 |
1/2.8" CMOS | 0.3X |
HD1500MET-M |
HDMI/USB 2.0 | Color | 2-6MP |
3264 x 1840 Static |
60fps by HDMI 30fps by USB 2.0 |
1/2.8" CMOS | 0.3X |
HD1500MET-AF |
HDMI/USB2.0 | Color | 2-6MP |
3264 x 1840 Static |
60fps by HDMI 30fps by USB 2.0 |
1/2.8" CMOS | 0.3X |
HD1500MET-M-AF |
HDMI/USB2.0 | Color | 2-6MP |
3264 x 1840 Static |
60fps by HDMI 30fps by USB 2.0 |
1/2.8" CMOS | 0.3X |
HD1000-LITE |
HDMI/USB 2.0 | Color | 5MP |
2592 x 1944 |
15fps by HDMI |
1/2.5" CMOS |
0.3X |
HD1000-LITE-M |
HDMI/USB 2.0 | Color | 5MP |
2592 x 1944 |
15fps by HDMI |
1/2.5" CMOS |
0.3X |
HD1600T |
USB 3.0 | Color | 16MP | 4608 x 3456 |
25fps by USB 3.0 |
1/2.33" CMOS |
0.3X |
SS500-MC |
Wifi | Color | 5MP | 2912 x 1640 | 60fps by Wifi | 1/2.3" CMOS | 0.3X |
WF300 |
Wifi | Color | 8MP | 3200 x 2400 | 60fps by USB 2.0 30fps by Wifi |
1/2.8" CMOS | 20-43mm Eyepiece Mount |
WF200 |
Wifi | Color | 5MP | 2592 x 1944 | 40fps by USB 2.0 15fps by Wifi |
1/2.8" CMOS | 0.3X |
WF100 |
Wifi | Color | 5MP | 2592 x 1944 | 30fps by Wifi | - | - |
X-1000U |
USB 2.0 | Color | 5MP | 2592 x 1911 | 10fps by USB 2.0 | 1/2.8" CMOS | 0.3X |
MIS-PL-DV24 |
USB 2.0 | Color | 2MP | 1600 x 1200 | 30fps by USB 2.0 | 1/2" CMOS | 0.5X |
DK-LITE-B |
USB 2.0 | Color | 1.5MP | 1440 x 1080 | 10fps by USB 2.0 | 1/2.5" CMOS | 0.5X |
DK1000CB |
USB 2.0 | Color | 2MP | 1600 x 1200 | 15fps by USB 2.0 | 1/2" CMOS | 0.5X |
DK1000M |
USB 2.0 | Monochrome | 1.3MP | 1280 x 1024 | 30fps by USB 2.0 | 1/2" CMOS | 0.5X |
DK3000C |
USB 2.0 | Color | 3.1MP | 2048 x 1536 | 12fps by USB 2.0 | 1/2" CMOS | 0.5X |
DK5000C |
USB 2.0 | Color | 5MP | 2592 x 1944 | 5fps by USB 2.0 | 1/2.5" CMOS | 0.7X |
HD2000C |
USB 2.0 | Color | 2MP | 1920 x 1080 | 60fps by USB 2.0 | 1/3" CMOS | 0.3X |
ST1000C |
USB 3.0 | Color | 5MP | 2592 x 1944 | 60fps by USB 3.0 | 1/2.5" CMOS | 0.5X |
Frequently Asked Questions
Q: Start the software and get the camera recognized, but the preview is all black.
A: Check whether the anti-dust cap on the C-mount is removed. If already removed and attach the camera to the microscop, check whether the lighting path toggle switch to the camera. Then try to extend the exposure time and gain to get brighter images.
Q: The imaging scene from the eyepiece is in focus but the live images from the camera are still out of focus.
A: This is because the camera and the eyepiece are in different focal planes. Can consider to use adjustable adapter to connect camera to the microscope trinocular, and the adjust the adapter to make the live image in focus.
Q: There are some shadows on the image and the shadows always stay in the same position even when the sample is moved.
A: Possible reasons:
1. The anti-dust film on the camera C-mount is not removed. Remove the anti-dust film
2. Check to see if there is any dirt on the objective. Clean the objective.
3. Some dust on the surface of the camera IR filter. Clean the camera optical port.
Q: Camera frame rate is extremely slow.
A: Possible reasons:
1. Preview resolution is too high. Try lowering the resolution and check the change of the frame rate.
2. Exposure time is too long. If need exposure time longer than 200ms, try to use higher gain to get brighter images.
3. Computer issue. Computer is very old or the motherboard chipset is Intel 8 Series/C220 series.
Q: Start the software and get the error message: can not recognize the camera or No camera.
A: Possible reasons:
1. The camera USB cable is not well connected. Reconnect the camera again.
2. Check whether the camera is connect to the USB port on the front of the mainframe. If so, then connect it to the USB port on the back of the mainframe. The USB ports on the front of the mainframe are the extended ports from the motherboard which can not provide stable voltage and current for cameras.
3. The camera itself needs extra power supply but does not switch on the power. TrueChrome is required to switch on power, attach to the PC and then restart the software. TCC-6.1ICE is required to plug in power to be recognized by PC.
4. The camera driver is not installed or failed to install. Go to the "Device Manager" > "Imaging Devices" and check whether the camera is listed WITH YELLOW FLAG. Then re-install the driver again. If still fail to install to driver, please contact camera technical support for help.
Q: Image Field of View (FOV) is much smaller than the scene can be seen from the eyepieces.
A: Possible reasons:
The camera sensor size is not 1 inch. It needs reduce lens to get bigger FOV.
Low resolution is used to preview. Set full resolutionion.
The reduce lens does not match the camera sensor size.
Q: When push “Capture” button, sometimes the saved images are quite blurry.
A: It could be because some slight vibration happens on the camera during capturing the images.
Q: Security shield on ISCapture shortcut.
A: Some anti-virus or firewall softwaree installed in the PCs will identify the DLL files from ISCapture as virus and automatically isolate or delete the ISCapture software files. If have the warning message to delete or isolate the DLL files during the ISCapture installation, please ignore the warning message or set the ISCapture as trusted software. Otherwise, the ISCapture can not be used normally.
Q: Newer version software con not recognize the old cameras.
A: Currently, all the newer version software ISCapture is compatible with the previous version cameras EXCEPT TCA Series.
Q: After doing the measurement on the live images, the captured image is without any measurement data.
A: To save the live measurement on captured images, check the “Combined Measurements” checkbox in the File Save tab and then capture images. While doing the still image measurements, only click the Save or Save As on the right hand side shortcut to save the data on the images.
Q: The live images and the captures images color is quite different from the one we can see from the eyepieces.
A: Because of the different lighting source, White Balance is needed to correct the image color.
Q: How to do quick White Balance?
A: White Balance while attached to camera to stereo microscope: Use a white paper to replace the sample. Click on “White Balance” to correct the image color > Remove the white paper and put back the sample.
White Balance while attach the camera to the biological microscope: Move the sample slide to the blank area. Click on “White Balance” and move back the sample.
Q: After install ISCapture and firstly start the software, but get the error “The program can’t start because MSVCP100.dll is missing from your computer. Try reinstalling the program to fix this problem.”
A; This is because the operating system lack of some Visual C++ 32bit library files which the ISCapture needs to call them. Without these files, the software can not be started normally. Install the patch VCredist_x86.exe (can be found in the CD that comes with the camera or go to http://www.microsoft.com/en-us/download/details.aspx?id=5555
Q: Start the ISCapture but get the error “Unable to execute file C:\Program Files\ISCapture\ISCapture.exe CreateProcess failed; code 740.
A: Completely remove the ISC Capture, reboot the PC and then right click on ISCapture installer (ISCapture Setup.exe) and select “Run as Administrator” to install the ISCapture. When you first start the software right click on the ISC icon and select “Run as Administrator” to start it.
Q:When start ISCapture, get error message “Cannot find the USB Key!”
A: The software is encrypted. Specific USB key is needed to attach to the computer port first.
Q:After capturing several images, it takes more and more time to save a frame image. Sometimes it is even up to more than 30 seconds, and then finally the software hang or crash.
A: If the image save directory is the network driver, during uploading the files to network driver, it will significantly increase the COP usage. When the CUP usage is up to 100%, the software will hang or crash. Recommend to change the file save directory to the computer hard disk.
Q: Whether can share the calibration files on different PCs?
A: If using the ISCapture earlier version than V4.0: Go to the folder “Application Data/ISCapture” in system disk, find the file “calibrationTable.ini” and copy it to another PC under the same directory. (The “Application Data” folder is a hidden folder, you might need to make the system invisible visible first.)
If it is ISCapture V4.0 or later, go to the Parameter tab and click “Backup” to backup the parameter settings and copy them to another PC to restore them.
Q:After install the ISCapture and every time I run the software i get the error:
A: This is because some program in the user’s PC is using the library file ‘libiomp5md.dll’which will conflict with the ISCapture. So far as we know, the software GoPro Studio will conflict with ISCapture. To solve this issue, please try to remove the libiomp5md.dll from the C:\Windows\System32 folder while using the ISCapture.
Q: Shortcut keys for ISCapture to capture still images and videos:
A: With ISCapture V3.6.6 or later, running the ISCapture first, Press F9 key on the keyboard to capture images. Press F10 to start the video recording. If in manual recording mode, press F11 to stop the recording.
Q: On preview images, lots of horizontal lines appear.
A: This is because of the lighting frequency. Extend exposure time or turn off the filament lamp or fluorescent lamp in the environment to solve this issue.
Q:Recording issue when connected to the HD1500T/HD1000 Series to the monitor and recorded video directly to the SD card? If so, do you know what the capacity of the SD card the user used during recording the videos?
A:When recording videos to the SD card, the camera only supports the SD card with format SDHC. It can not work with the SD card format SDXC. And max. capacity of the SDHC format SD card is 32GB which means the SD card with capacity >= 64GB, is format SDXC.
If already use SDHC format SD card, please help to confirm the information below:
1). Whether the customer used the SD card came with the HD1500T/HD1000 camera?
2). If not, what exactly the model of the SD card the customer used? Maybe some picture of the SD card.
If got the issue while connect the camera to the computer, I need to confirm below information:
1). The software always stop recording AUTOMATICALLY after 5-10 minutes?
2). Whether the software or the computer freeze if MANUALLY stop the recording?
Product Information:
• Manufactured: 100% MADE IN JAPAN
• MA951D/30 Manufactured: 100% MADE IN USA
• Warranty: LIMITED LIFETIME WARRANTY
• Customer Support: 1-(800) 832-0060 (U.S.A Based)
The Short UNIMAC Series features include:
Short UNIMAC Macroscopes:
Short UNIMAC Series (Short-Back Focus) is a high performance direct-to-camera zoom lens system offer a wide array of features making them perfect for industrial, medical, educational and research applications. The Short UNIMAC series of macrozoom lenses couples directly to a CCD or CMOS video camera and allows a shorter profile facilitating use in situations where space is very restricted. These versatile modular lens systems are ideally suited for a variety of free standing or OEM applications. Compatible with digital or analog CCD and CMOS cameras.
Superb optical quality and mechanical flexibility allow the user to cover a wide spectrum of viewing needs. A variety of auxiliary lenses, focus blocks, illumination systems, digital camera adapters and other components allows you to easily customized the system for your specific situation.
The Short UNIMAC Series lenses have a 6.4:1 zoom ratio and maintain parfocality throughout their extended zoom range. The Short UNIMAC lenses are available in either a standard zoom configuration, or a detent zoom configuration, which is useful for calibration and measurement purposes.
COMPONENTS AND ACCESSORIES FOR SHORT UNIMAC SERIES
MACRO ZOOM OBJECTIVES
• MS-40D: Short UNIMAC 0.28X to 1.8X with C-mount adapter and detent W.D. 94mm
• MS-45D: Short UNIMAC 0.41X to 2.6X with C-mount adapter and detent W.D. 94mm
• MS-50D: Short UNIMAC 0.7X to 4.5X with C-mount adapter and detent W.D. 94mm
• MS-50R: Short UNIMAC 0.7X to 4.5X with C-mount adapter and iris W.D. 94mm
• MS-50DR: Short UNIMAC 0.7X to 4.5X with C-mount adapter, iris and detent W.D. 94mm
FOCUS BLOCKS (45MM INNER DIAMETER)
• MS-51/05: Coarse focus block. Fits 20mm mounting post
• MS-52/05: Inclinable coarse focus block (With 5/8" mounting pin)
• MS-53/05: Coarse and fine focus block. Fits 20mm mounting post
• MS-54/05: Inclinable coarse and fine focus block (With 5/8" mounting pin)
AUXILIARY LENSES
• MS-6: Auxiliary lens 0.5X, W.D. 182mm (7.24")
• MS-7: Auxiliary lens 0.75X, W.D. 105mm (4.1")
• MS-8: Auxiliary lens 1.5X, W.D. 44mm (1.7")
• MS-9: Auxiliary lens 2.0X, W.D. 29mm (1.1")
• MS-13/PT#2: Adapter for mounting 60mm I.D. ringlight
POLE TYPE STANDS
• MS-51: Coarse focus block, pole type plain stand, black and white stage plate
• MS-53: Coarse and fine focus block, pole type plain stand, black and white stage plate
• PK/SP-1: Plain ergonomic PK stand without a F holder
• PKL-2/MS-51/05: LED transmitted light ergonomic stand with coarse focus block (MS-51/05)
• BD-M-LED: Pole type stand with rotatable and sliding Y-axis mirror in base with locking tension ring and “pseudo” LED transmitted light darkfield illumination, with variable intensity controls, clear glass stage plate, two stage clips. Wide ergonomic base dimensions is 12" (L) x 15" (W), (9.5" pillar height, 20mm diameter pole) requires MS-51/05 or MS-53/05 holder Integrated automatic voltage sensing power supply 115/240V
WIDE SURFACE LAMINATE BOARD STANDS
• SBU: Large universal stand with crossarm, 221 /3" x 19¼" base
• UL: Large universal stand with rotatable stand for light source, 221 /3" x 19 ¼"
BOOM STANDS
• S-1100: Universal single boom stand with 20mm mounting post accepts F, FK, FC holder, vertical pole 15.11" (384mm) diameter 1.46" (37.2mm), horizontal arm 21.5" (544mm) diameter 1.46" (37.2mm), base 285mm x 260mm x 15mm, 40lbs
• S-1300: Universal single boom stand with 5/8" bonder pin acceptance for FS, FSC, FS/76 holder vertical pole 15.11" (384mm) diameter 1.46" (37.2mm), horizontal arm 21.5" (544mm) diameter 1.46" (37.2mm), base 285mm x 260mm x 15mm, 40lbs
• S-2100: Universal dual arm boom stand with 20mm mounting post for F, FK, FC holder, vertical pole 15.11" (384mm) diameter 1.46" (37.2mm), horizontal arm 21.5" (544mm) diameter 1.46" (37.2mm), base 285mm x 260mm x 15mm, 40lbs
• S-2300: Universal dual arm boom stand with 5/8" bonder pin acceptance for FS, FSC, FS/76 holder, vertical pole 15.11" (384mm) diameter 1.46" (37.2mm), horizontal arm 21.5" (544mm) diameter, 1.46" (37.2mm), base 285mm x 260mm x 18mm, 40lbs
NOTE: S-4000 Series horizontal poles 25.5mm diameter, vertical pole 29mm diameter
• S-4100: Universal single boom stand with 20mm mounting post for MS-51/05 or MS-53/05 holder, vertical pole 400mm (15.74") and horizontal pole 530mm (20.87")
• S-4200: Universal single boom stand with 20mm mounting post for MS-51/05 or MS-53/05 holder, vertical pole 610mm (24.0") and horizontal pole 530mm (20.87")
• S-4300: Universal single boom stand with 5/8" bonder adapter (MA552) for MS-52/05 or MS-54/05 holder, with vertical pole 400mm (15.74") and horizontal pole 535mm (21.06")
• S-4400: Universal single boom stand with 5/8" bonder adapter (MA552) for MS-52/05 or MS-54/05 holder, vertical pole 610mm (24.0") and horizontal pole 535mm (21.06")
• S-4500: Table clamp single boom stand with 20mm adapter for use with MS-51/05 or MS-53/05 holder, vertical pole 400mm (15.74") and horizontal pole 535mm (21.06") S-4600: Table clamp single boom stand with 5/8" adapter (MA552) for use with MS-52/05 or MS-54/05
HEAVY DUTY BOOM STANDS
• BAS-2: Ball bearing stand with dual horizontal arms, adjustable from 5.5" to 18", 13" x 13" x 1.5" base, 25" vertical post, safety clamp and 20mm straight mounting post for MS-51/05 or MS-53/05 holder (Note: Socket Head cap screw for base: 1/2" x 2" 13TP)
• BAS-3: Ball bearing stand with dual horizontal arms, 13" x 13" x 1.5" base, 25" vertical post, safety clamp for MS-52/05 or MS-54/05 holder
• MA552: 5/8" Bonder pin adapter to connect MS-52/05 or MS-54/05 holder to S-4300, S-4400, S-4600 and U stand
• U/PT#1: Drop down mounting post for MS-51/05 or MS-53/05 holder, 20mm diameter, 71mm length
• FC11: Mounting pin extension (The FC11 is required when mounting the FC 25.00 focus block on the 71mm long mounting pin of the S-4000 series boom stands)
ARTICULATING ARM STANDS
• SAS-1: Articulating Stand with 13" x 13" x 1.5" base, 16" vertical post, safety clamp and 20mm drop down mounting post. 6" arm, 31" reach for MS-51/05 or MS-53/05 holder
• SAS-2: Articulating Stand with 13" x 13" x 1.5" base, 16" vertical post, safety clamp and 20mm drop down mounting post. 12" arm, 37" reach for MS-51/05 or MS-53/05 holder
• SAS-3: Articulating Stand with 13" x 13" x 1.5" base, 16" vertical post, and OS-LAEA (Lift Arm End Adapter) 5/8" bonder pin dowel, 6" arm 31" reach for MS-52/05 or MS-54/05 holder
• SAS-4: Articulating Stand with 13" x 13" x 1.5" base, 16" vertical post, and OS-LAEA (Lift Arm End Adapter) 5/8" bonder pin dowel, 12" arm 37" reach or MS-52/05 or MS-54/05 holder
• FA-3: Articulating flex arm with a table clamp, accepts a 5/8" bonder pin focus block, FS and FSC or accepts a 20mm focus block by adding BAS-20SP, 20mm drop down post, for use with F, FX, FC focus block, 40" distance from vertical post to optical center or MS-52/05 or MS-54/05 holder
• BAS-20SP: 20mm straight drop down post for FA-3 or BAS-2 stand 4" in length
HALOGEN FIBER OPTIC ILLUMINATION
• FL151: Halogen Dual arm 150W fiber optic illumination system - 110/115V (Complete system)
• FL151/220: Halogen Dual arm 150W fiber optic illumination system - 220/240V (Complete system)
• FL150/70: Spare bulb - 21V 150W (EKE) (For FL or FT series)
FIBER OPTIC ILLUMINATION COMPONENTS
• FL150/115: Halogen Light source only for fiber light guide, 110/120V
• FL150/200: Halogen Light source only for fiber light guide, 220/240V
• FT190/115: Halogen Light source only for fiber light guide, 120VAC, 50/60Hz, 21V 150W
• FT190/230: Halogen Light source only for fiber light guide, 230VAC, 50/60Hz, 21V 150W
• FL150/65: Mini annular fiber optic ring light for MS-3 or MS-3D (Requires MS-22)
FLUORESCENT ILLUMINATORS
• MA305/100: Ring fluorescent illuminator, 110V, with inverter starter (Complete system)
• MA305/200: Ring fluorescent illuminator, 220/240V, with inverter starter (Complete system)
• MA305/05: Spare ring fluorescent tube, 8 watt DL (daylight)
HALOGEN ILLUMINATORS
• MA264H/100: Versatile illuminator, 110V with transformer, 6V, 20W halogen (T.S.L/DISC) (Complete system)
• MA264H/200: Versatile illuminator, 220/240V with transformer, 6V, 20W halogen (T.S.L/DISC) (Complete system)
• MA260/05: Spare Bulb, 6V 20W, halogen (No pip, replaces GE #788)
• FT191/B26: Dual arm fiber illumination system with adapters for S-4000 Boom Stand. Includes FT190/06 dual arm rigid self-supporting 20" Bifurcated/fluid bundle 40" flaccid with 15.8mm insert and FT190/06-26, 26mm adapter for dual rigid/flaccid bundle with three threaded holes, FT190/50 - qty# 2 focusing lens, FT190/115 light source and FTI-02 - qty# 1, 16mm light source adapter
• FT191/B26/230: Dual arm fiber illumination system with adapters for S-4000 Boom Stand. Includes FT190/06 dual arm rigid self-supporting 20" Bifurcated/fluid bundle 40" flaccid with 15.8mm insert and FT190/06-26, 26mm adapter for dual rigid/flaccid bundle with three threaded holes, FT190/50 - qty# 2 focusing lens, FT190/230 light source and FTI-02 - qty# 1, 16mm light source adapter
LED FIBER OPTIC ILLUMINATIORS
• FT193/B26: Single arm fiber illumination system with special mounting adapters for S-4000 horizontal arm for boom stands, includes FT190/13 single arm rigid self-supporting 20" fluid bundle with 15.8mm insert and FT190/06-26 (110V) - qty# 1 light source and FTI-02 - qty# 1, 16mm light source adapter
• FT193/B26/230: Single arm fiber illumination system with special mounting adapters for S-4000 horizontal arm for boom stands, includes FT190/13 single arm rigid self-supporting 20" fluid bundle with 15.8mm insert and FT190/06-26 (220V) - qty# 1 light source and FTI-02 - qty# 1, 16mm light source adapter
• FTM191: Dual arm fiber illumination system - 120VAC, 35W (USA) - Includes: FTM/115 - 35W LED light source with variable intensity control, FT190/05 self-supporting, dual arm light guide and two FT190/50 focusing lenses, 25mm adapter for boom horizontal arm
• FTM192: Annular fiber illumination system - 120VAC, 35W (USA) - Includes: FTM/115 - 35W LED light source with variable intensity control, FT190/10 Annular Light guide (60mm I.D.) 25mm adapter for boom horizontal arm
• FTM193: Single arm fiber illumination system - 120VAC, 35W (USA) - Includes: FTM/115 - 35W LED light source with variable intensity control, FT190/75 - 24" self-supporting, single arm light guide and one FT190/50 focusing lenses, 25mm adapter for boom horizontal arm
LED FIBER OPTIC ILLUMINATIORS
• FT193/B26: Single arm fiber illumination system with special mounting adapters for S-4000 horizontal arm for boom stands, includes FT190/13 single arm rigid self-supporting 20" fluid bundle with 15.8mm insert and FT190/06-26 (110V) - qty# 1 light source and FTI-02 - qty# 1, 16mm light source adapter
• FT193/B26/230: Single arm fiber illumination system with special mounting adapters for S-4000 horizontal arm for boom stands, includes FT190/13 single arm rigid self-supporting 20" fluid bundle with 15.8mm insert and FT190/06-26 (220V) - qty# 1 light source and FTI-02 - qty# 1, 16mm light source adapter
• FTM191: Dual arm fiber illumination system - 120VAC, 35W (USA) - Includes: FTM/115 - 35W LED light source with variable intensity control, FT190/05 self-supporting, dual arm light guide and two FT190/50 focusing lenses, 25mm adapter for boom horizontal arm
FTM192: Annular fiber illumination system - 120VAC, 35W (USA) - Includes: FTM/115 - 35W LED light source with variable intensity control, FT190/10 Annular Light guide (60mm I.D.) 25mm adapter for boom horizontal arm
• FTM193: Single arm fiber illumination system - 120VAC, 35W (USA) - Includes: FTM/115 - 35W LED light source with variable intensity control, FT190/75 - 24" self-supporting, single arm light guide and one FT190/50 focusing lenses, 25mm adapter for boom horizontal arm
LED RING LIGHT ILLUMINATORS
• MA951D/30: Mini annular ring illuminator 44mm inner diameter with 30 LED array, daylight. 600.00 62mm minimum working distance and has high strength aluminum alloy. Includes auto voltage sensing power supply, 3 segment control with rheostat
Double click to read at full screen
Download Brochure (PDF)
**UPDATE ON HD1500MET & HD1500MET-M SOFTWARE 2/14/2019**
Double click to read at full screen
Download Software Update Instructions (PDF)
Download update.bin
Download MAC Software CaptureV2.1.3 - 3/16/2020
Download Older MAC ISListen Capture Software
Download ISListen MAC Installation Guide (PDF)
Download Camera Driver (ZIP)
Download TCapture Software (ZIP)
Double click to read at full screen
Download Software Manual (PDF)
Double click to read at full screen
Download Menu Quick Guide (PDF)
Double click to read at full screen
Download Calibrate Guide (PDF)
Double click to read at full screen
Download FAQ Sheet (PDF)
Double click to read at full screen
Download TCapture Software Manual (PDF)
Double click to read at full screen
Download HD1500MET Calibration Metric Measurement Instruction (PDF)