Body: Trinocular, Rotatable 360°, Cast Aluminum Alloy Construction
Trinocular Port: 23.2mm I.D, 25.2mm O.D
Zoom Ratio: 6.5:1
Zoom Range: 3.06x – 19.7x with .45X Auxilliary lens and 12.5x eyepieces
Zoom Knobs Markings: 0.7, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5
Zoom Control: Dual, graduated, bilateral
Magnification: 3.06x - 19.7x (12.5x eyepieces)
Objective Lens: Brass Construction
Field of View: 81.6mm - 12.7mm
Working distance: 250mm
Eyetube Inclination: 30°
Eyepieces: 12.5x (5x, 7.5x, 10x, 15x, 20x, and 30x - optional)
Interpupillary Distance: 54mm - 75mm
Dioptric Adjustment: Dual (+/- 5 diopters)
Extended Mag Range: 3.06x - 84.37x (With auxiliary lenses and eyepieces)
Extended Working Distances: 57mm - 250mm (With auxiliary lenses and eyepieces)
Auxiliary Lenses: 0.35x (250mm) (0.28x (300mm), 0.44x (184mm), 0.5x (174mm), 1.5x (57mm), and 2x (36.6mm) - optional)
Mounting: Fits 84.5mm Diameter Focus Holders
Manufacturer: MADE IN JAPAN
Warranty: LIMITED LIFETIME WARRANTY
Includes:
• Stereo Microscope Body (Special Trinocular Zoom Stereo Microscope with 30° eyetube inclination)
• 12.5X Eyepieces (Paired)
• Stand (Ergonomic slim pole stand with built in inclineable oblique LED illumination and extended 12.4mm pole)
• Black and White Reversible stage plate (MA569)
• Illumination Source (Fiber optic halogen, fiber optic LED, fluorescent ring or LED illumination)
• 0.35X Auxiliary Lens -Working Distance 250mm or 9.84" (MA792)
• Meiji Techno Dust Cover (MA703)
• Rubber Eyeguards/Eyeshields (Paired) (MA600)
• EMZ Meiji Techno Instruction Manual
• Limited Lifetime Warranty
Package Information:
• 18 lbs
• 25 x 15 x 18 inches
Meiji Techno offers the economically priced EMZ Hair Transplant Microscope Stereo Zoom System Series for hair transplantation procedures. There are two primary techniques for hair transplantation currently in use. The FUE (Follicular Unit Extraction) and the FUT (Follicular Unit Transplantation) methods. They differ primarily in the way hair follicles are extracted from the donor area. The FUT process involves removing a small strip of tissue from the back of the head, from which the donor hair follicles will be extracted. The hair follicles are harvested from the strip by a skilled clinical team before being individually transplanted to the recipient areas. In most cases, and especially cases of advanced hair loss, FUT is the preferred method because it allows the physician to fully utilize the scalp area to deliver results consistent with patient expectations. FUT typically allows for the greatest number of grafts to be transplanted in a single session. Overall, the EMZ Hair Transplant Microscope Series helps with these laboratory procedures with its long working distance length, its increased focal depth and its wide field number. The trinocular zoom body offers direct light to all three viewing ports simultaneously. This series also features Greenough optics for enhanced image flatness and contrast. As a result, views of three dimensional surfaces are sharp with excellent depth characteristic. The Hair Transplant system offers a high intensity inclinable oblique LED illumination with up to 20,000 hour bulb life on a low profile ergonomically designed compact stand that offers superior performance at low cost. HDMI and USB 2.0 or Wifi cameras are available for photo microscopy to document procedures for training and/or teaching documentation.
Our systems will give your technicians good Japanese optical system with ergonomics in mind. Our turn key hair transplant systems are affordable complete package with modularity in mind in case one wants to add magnification, increase working distance or include cameras to their laboratory microscope system.
Recommended for:
• FUT (Follicular Unit Transplantation)
• FUE (Follicular Unit Extraction)
NOTE: The EMZ Hair Transplant System is a complete microscope system.
• Stereo Microscope Body (Binocular or Trinocular Zoom Stereo Microscope)
• 12.5X Eyepieces (Paired)
• Stand (Ergonomic slim pole stand with 12.4mm horizontal pole)
• Illumination Source (built-in inclinable oblique LED illumination with rheostat)
• Auxiliary Lens (gives ample working distance)
Replacement Bulbs Listed by Part Number
NOTE: The size of these images will vary and some images have been re-sized to fit this page. Do not rely on the size of these images to determine which bulb you need.
NOTE: Incident light shines down from above; transmitted light shines up through the specimen from below.
MA111 | MA260/05 | MA261/SL-10 | MA263/05 MA263/10 | MA264/05 | MA275/05 |
Part Number | Description | Application |
MA111 | 12V 10W | Incident light:ST-3, SKT-1B, SKT-2B, SKT-3B, GS2000 Incident & transmitted light: SKT-BT, SKT-2BT, SKT-3BT Transmitted light: STC-3 |
MA260/05 | 6V 20W Halogen | For MA260, MA264H, and MA264EX illuminators |
MA261/SL-10 | 115V 20W |
For "B" Stand and MA261/35 (TM200 Series illuminator)
|
MA263/05 | 115V 30W | For MA263 illuminators |
MA263/10 | 220/240V 30W | For MA263 illuminators |
MA264/05 | 6.5V 2.75A | For MA264 illuminators |
MA275/05 | 12V 50W | For ML5000 Series 50W models; ML7500, ML8500 All MT7500, MT8500 series |
MA305/05 | MA309/05 | MA326 | MA350/10 MA350/20 | MA361/10 MA362/10 |
Part Number | Description | Application |
MA305/05 | 8W Ring Fluorescent | For MA305/100, MA305/200 ring fluorescent illuminators |
MA309/05 | 4W Tube Fluorescent | For MA309 fluorescent box illuminators for GEM stand |
MA326 | 6V 30W Halogen (G4 base type) |
For ML2000 and ML5000 Series 30W models; all VT Series Models, IM7100, IM7200, ML2000, ML7000, ML8000, ML9000, TC5100, TC5200, TC5300, TC5400, TC5500, TC5600
All MT Series 30W models; all RZT & RZDT Stands |
MA350/10 | 115V 30W | For GEM stand transmitted light |
MA350/20 | 220/240V 30W | For GEM stand transmitted light |
MA361/10* | 110V 20W | Half-silvered bulb for TM400 Series 20W models (DISCONTINUED) |
MA361/20* | 220/240V 20W | Half-silvered bulb for TM400 Series 20W models |
MA362/10* | 115V 30W | Half-silvered bulb for TM400 Series 30W models (DISCONTINUED) |
MA362/20* | 220/240V 30W | Half-silvered bulb for TM400 Series 30W models(DISCONTINUED) |
MA560 | MA561 | MA570 | FL180/70 FL150/70 | MA357 | MA358 | MA590 |
Part Number | Description | Application |
MA560 | 6V 1.2A Tungsten | Incident light: AB, ABZ, PB Stands All BM/BMK Series models |
MA561 | 6V 1.2A Tungsten |
Transmitted light: AB, ABZ, PB Stands Note: MA560 and MA561 may appear to be identical, but they are not interchangeable. |
MA570 | 6V 10W Halogen |
Incident & transmitted light: ABE, ABH, ABZH, PBH Stands
|
FL150/70 | 21V 150W Halogen | For Fiber Optic Light sources: All FT190 and FL150 Series |
FL180/70 | 21V 150W Halogen | For FL180, FL181 & FL182 fiber optic illuminators |
MA357 | 8V 12W Tungsten | Frosted - Fits Meiji Techno MT5500 Series Microscopes |
MA358 | 8V 12W Tungsten | Clear - Fits Meiji Techno MT5500 Series Microscopes |
MA590 | 110V 15W Tungsten | Frosted - Fits Meiji Techno PBM Series Stands |
DC Arc Lamps
Part Number | Description | Application |
BA005 | HBO 100W Mercury DC Arc Lamp | TC5000 Series & MT6000 Series Equipped with Epi-Fluorescence Lamphouses |
BA013 | XBO 75W Xenon DC Arc Lamp | |
BA014 | XBO 100W Xenon DC Arc Lamp |
BA005 Information:
Brand: Ushio
Technology: Short-Arc Mercury
Useful Life Hours: 200
Lumen Output: 2200
Actual Wattage: 100
Voltage: 20
Base Type: SFa7.5+SFa9
Length (Inch): 3.54
Diameter (Inch): .394
Manufacturers Notes: The HBO 100W BA005 is a Mercury Arc 20V 100 W Lamp with a SFa7.5-2 base
This product is also a direct replacement for the following items:
*Discontinued - subject to stock on hand
Click HERE for more Bulb info.
Light bulbs in microscope illuminators need to be replaced periodically. The bulbs on this page are most commonly used in Meiji Techno illumination systems. If you own a Meiji microscope and need a replacement, you should be able to purchase it at your local Meiji Dealer. Some older models or specialized microscopes may use bulbs that are not listed here. If you cannot find the correct bulb, please contact our technical support staff to assist you. Click HERE for information on Lamp Safety, Handling and Disposal.
Tips on extending bulb life
Bulbs have a rough life in a microscope: burning in an enclosed area for hours on end with a finite lifetime, the effects of too much heat and not enough ventilation, DC current from the dimmer circuit slowly thinning the metal of the filament. And with bulbs nowadays being manufactured more and more cheaply, the cumulative effect is not good for bulb longevity.
If the bulb is halogen or DC Arc Lamp type, DO NOT TOUCH THE GLASS with your bare hands when installing bulbs. Use the plastic bag it comes in to install the bulb. DO NOT jar or bump or run your scope in an environment that has excessive vibration. Turn your scope off if you do not need it on. Some bulbs have a rated life of only 100 - 200 hours so if you use your scope full time, be prepared to use bulbs.
Halogen bulbs in microscopes and fiber optic light sources can also have problems if the socket is worn out; i.e. the connection cannot sink enough heat away from the bulb and/or the electrical connection is weak. If your scope is an old workhorse who's starting to eat bulbs, check the bulb socket out for poor contact and discoloration of the contact. The bi-pin type bulb should push stiffly into the socket. If not, or if it wobbles around excessively, the socket is too old and needs replacement.
EMZ-250TR-HT Includes:
• EMZ-18TRB: Trinocular Zoom Stereo Body with 0.7X?– 4.5X magnification, 30° eyetube
• MA520: Super Widefield Eyepiece 12.5X (paired) (Accepts 25mm reticle mount)
• MA792: 0.35X Auxiliary lens, W.D. 250mm (9.84")
• PKL-1/310: Pole type stand with incident light LED illumination system, coarse focusing slide block, 5 watt LED incident illuminator, variable intensity control, reversible black and white stage plate, two stage clips, integrated automatic voltage sensing power supply 115/240V,
• MA151/8TR: 0.6X C-mount adapter (factory installed, built-in)
• EMZ-8TR/PT#1: Trinocular tube to increase F.O.V. with C-mount adapter (optional)
Double click to read at full screen
Download Brochure (PDF)
Double click to read at full screen
Download Brochure (PDF)
Double click to read at full screen
Download Manual (PDF)